Calibrated high-precision 17O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance

被引:107
作者
Steig, E. J. [1 ,2 ,3 ]
Gkinis, V. [3 ,4 ]
Schauer, A. J. [1 ,2 ]
Schoenemann, S. W. [1 ,2 ]
Samek, K. [1 ,2 ]
Hoffnagle, J. [5 ]
Dennis, K. J. [5 ]
Tan, S. M. [5 ]
机构
[1] Univ Washington, IsoLab, Seattle, WA 98195 USA
[2] Univ Washington, Quaternary Res Ctr, Seattle, WA 98195 USA
[3] Univ Copenhagen, Niels Bohr Inst, Ctr Ice & Climate, DK-2100 Copenhagen, Denmark
[4] Univ Colorado, Inst Arctic & Alpine Res, Boulder, CO 80309 USA
[5] Picarro Inc, Santa Clara, CA 95054 USA
基金
美国国家科学基金会;
关键词
STABLE-ISOTOPE MEASUREMENTS; RATIO MASS-SPECTROMETRY; DEUTERIUM EXCESS; ABSORPTION-SPECTROSCOPY; ENHANCED ABSORPTION; ORGANIC-COMPOUNDS; CARBON-DIOXIDE; WATER SAMPLES; ICE CORE; OXYGEN;
D O I
10.5194/amt-7-2421-2014
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
High-precision analysis of the O-17/O-16 isotope ratio in water and water vapor is of interest in hydrological, paleoclimate, and atmospheric science applications. Of specific interest is the parameter (17)Oexcess (Delta O-17), a measure of the deviation from a linear relationship between O-17/O-16 and O-18/O-16 ratios. Conventional analyses of Delta O-17 of water are obtained by fluorination of H2O to O-2 that is analyzed by dual-inlet isotope ratio mass spectrometry (IRMS). We describe a new laser spectroscopy instrument for high-precision Delta O-17 measurements. The new instrument uses cavity ring-down spectroscopy (CRDS) with laser-current-tuned cavity resonance to achieve reduced measurement drift compared with previous-generation instruments. Liquid water and water-vapor samples can be analyzed with a better than 8 per meg precision for Delta O-17 using integration times of less than 30 min. Calibration with respect to accepted water standards demonstrates that both the precision and the accuracy of Delta O-17 are competitive with conventional IRMS methods. The new instrument also achieves simultaneous analysis of delta O-18, delta O-17 and delta D with precision of < 0.03 parts per thousand, < 0.02 and < 0.2 parts per thousand, respectively, based on repeated calibrated measurements.
引用
收藏
页码:2421 / 2435
页数:15
相关论文
共 71 条
[1]   Isotope fractionation of molecular oxygen during adsorption/desorption by molecular sieve zeolite [J].
Abe, Osamu .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (16) :2510-2514
[2]   Measuring variations of δ18O and δ2H in atmospheric water vapour using two commercial laser-based spectrometers: an instrument characterisation study [J].
Aemisegger, F. ;
Sturm, P. ;
Graf, P. ;
Sodemann, H. ;
Pfahl, S. ;
Knohl, A. ;
Wernli, H. .
ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (07) :1491-1511
[3]   The AME2003 atomic mass evaluation (II). Tables, graphs and references [J].
Audi, G ;
Wapstra, AH ;
Thibault, C .
NUCLEAR PHYSICS A, 2003, 729 (01) :337-676
[4]   A technique for the determination of 18O/16O and 17O/16O isotopic ratios in water from small liquid and solid samples [J].
Baker, L ;
Franchi, IA ;
Maynard, J ;
Wright, IP ;
Pillinger, CT .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1665-1673
[5]   High precision measurements of 17O/16O and 18O/16O ratios in H2O [J].
Barkan, E ;
Luz, B .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (24) :3737-3742
[6]   Diffusivity fractionations of H216O/H217O and H216O/H218O in air and their implications for isotope hydrology [J].
Barkan, Eugeni ;
Luz, Boaz .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) :2999-3005
[7]   High-precision delta H-2 and delta O-18 measurement for water and volatile organic compounds by continuous-flow pyrolysis isotope ratio mass spectrometry [J].
Begley, IS ;
Scrimgeour, CM .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1530-1535
[8]   Measurement of δ18O, δ17O, and 17O-excess in Water by Off-Axis Integrated Cavity Output Spectroscopy and Isotope Ratio Mass Spectrometry [J].
Berman, Elena S. F. ;
Levin, Naomi E. ;
Landais, Amaelle ;
Li, Shuning ;
Owano, Thomas .
ANALYTICAL CHEMISTRY, 2013, 85 (21) :10392-10398
[9]   CONVERSION OF HYDROGENIC MATERIALS TO HYDROGEN FOR ISOTOPIC ANALYSIS [J].
BIGELEISEN, J ;
PERLMAN, ML ;
PROSSER, HC .
ANALYTICAL CHEMISTRY, 1952, 24 (08) :1356-1357
[10]   Isotopic composition of water in the tropical tropopause layer in cloud-resolving simulations of an idealized tropical circulation [J].
Blossey, Peter N. ;
Kuang, Zhiming ;
Romps, David M. .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2010, 115