Global evaluation of WBGT and SET indices for outdoor environments using thermal imaging and artificial neural networks

被引:25
作者
Mahgoub, Ahmed Osama [1 ]
Gowid, Samer [1 ]
Ghani, Saud [1 ]
机构
[1] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
关键词
Heat stress; Thermal comfort; WBGT; SET; Outdoor environments; Artificial neural networks; AIR-TEMPERATURE; SURFACE-TEMPERATURE; ERROR REDUCTION; COMFORT;
D O I
10.1016/j.scs.2020.102182
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The health and well-being of occupants of outdoor environments are largely affected by thermal stress, and therefore a global assessment is essential. Wet-bulb globe-temperature (WBGT) is used as a heat stress indicator and standard effective temperature (SET) is used as a thermal comfort index for assessment of thermal comfort in indoor and outdoor environments. These indices are usually evaluated point-wise which could be sufficient for relatively small spaces, but not suitable for large outdoor environments. This research proposes using a system combining climate sensors readings and thermal imaging to globally evaluate WBGT and SET values for outdoor environments. The algorithm derives air temperature from surface temperature values obtained using a thermal imaging camera. The obtained results were validated using readings of available sensors. Point-wise validation showed that the proposed methodology yielded results with a maximum average error of 11.4% compared to the average of point-wise local measurement for the WBGT, and an error of 8.5% for the SET. To minimize the error, an error reduction model based on artificial neural networks has been implemented. The error was further reduced to a maximum average error of 1.76% and 1.25% for WBGT and SET respectively.
引用
收藏
页数:15
相关论文
共 41 条
[1]  
[Anonymous], 2017, ASHRAE Handbook
[2]   ANN-based error reduction for experimentally modeled sensors [J].
Arpaia, P ;
Daponte, P ;
Grimaldi, D ;
Michaeli, L .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (01) :23-30
[3]  
ASHRAE, 2017, ANSI/ASHRAE Standard 55-2017
[4]   CONTRIBUTION OF MODIS SATELLITE IMAGE TO ESTIMATE THE DAILY AIR TEMPERATURE IN THE CASABLANCA CITY, MOROCCO [J].
Bahi, Hicham ;
Rhinane, Hassan ;
Bensalmia, Ahmed .
3RD INTERNATIONAL GEOADVANCES WORKSHOP, 2016, 42-2 (W1) :3-11
[6]   Wet-bulb globe temperature (WBGT) - its history and its limitations [J].
Budd, Grahame M. .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2008, 11 (01) :20-32
[7]   Infrared Imaging analysis for thermal comfort assessment [J].
De Oliveira, Fabrice ;
Moreau, Sophie ;
Gehin, Claudine ;
Dittmar, Andre .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :3373-+
[8]   Impact of ventilation rates on indoor thermal comfort and energy efficiency of ground-source heat pump system [J].
Deng, Yelin ;
Feng, Zhuangbo ;
Fang, Jian ;
Cao, Shi-Jie .
SUSTAINABLE CITIES AND SOCIETY, 2018, 37 :154-163
[9]   Induction-Machines-Based Wind Generators With Neural Maximum Power Point Tracking and Minimum Losses Techniques [J].
Di Piazza, Maria Carmela ;
Pucci, Marcello .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (02) :944-955
[10]   Investigation into the differences among several outdoor thermal comfort indices against field survey in subtropics [J].
Fang, Zhaosong ;
Feng, Xiwen ;
Liu, Jianlin ;
Lin, Zhang ;
Mak, Cheuk Ming ;
Niu, Jianlei ;
Tse, Kam-Tim ;
Xu, Xiaoning .
SUSTAINABLE CITIES AND SOCIETY, 2019, 44 :676-690