Thermodynamic evaluation of SOFC-GT hybrid power and cooling system

被引:12
作者
Singh, Onkar [1 ]
Singh, Ragini [1 ]
机构
[1] Harcourt Butler Tech Univ, Mech Engn Dept, Kanpur, Uttar Pradesh, India
关键词
Solid oxide fuel cell; gas turbine; hybrid system; power and cooling; fuel utilization factor; OXIDE FUEL-CELL; GAS-TURBINE; CYCLE; PERFORMANCE; DESIGN; ANODE; MODEL; HEAT;
D O I
10.1080/15567036.2019.1663307
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Amongst various energy conversion systems, the fuel cell based direct energy conversion system appears to have good potential to mitigate the environmental impact along with being an alternate source for power generation. Fuel cells are quite attractive due to their capability to produce electricity directly without producing any harmful emissions in the environment. However, there exists ample scope for optimal utilization of energy interactions in it. Present work deals with the parametric investigation of the considered configuration of the solid oxide fuel cell (SOFC) and gas turbine (GT) hybrid system coupled with a refrigeration cycle for yielding power and cooling together. The hybrid power and cooling system rely upon the SOFC for direct electricity generation along with shaft work from the GT. For better energy utilization, it is proposed to utilize the GT exhaust energy for steam generator and running the vapor absorption refrigeration system to meet the power generation and cooling requirements, respectively. Novelty of this work lies in the effective energy utilization by integration of cooling with power in SOFC-GT hybrid system. Here thermodynamic modeling of the considered hybrid power and cooling system has been carried out based on the first law of thermodynamics. The computer simulation of SOFC-GT hybrid power and cooling system is used for studying the effect of different parameters on the cycle performance. Here maximum efficiency of 64.74% is found at 6 cycle pressure ratio, 1400 K turbine inlet temperature and 288 K ambient temperature.
引用
收藏
页码:1975 / 1989
页数:15
相关论文
共 21 条
[1]   Anode-supported intermediate-temperature direct internal reforming solid oxide fuel cell - II. Model-based dynamic performance and control [J].
Aguiar, P ;
Adjiman, CS ;
Brandon, NP .
JOURNAL OF POWER SOURCES, 2005, 147 (1-2) :136-147
[2]   Hybrid solid oxide fuel cells-gas turbine systems for combined heat and power: A review [J].
Buonomano, Annamaria ;
Calise, Francesco ;
d'Accadia, Massimo Dentice ;
Palombo, Adolfo ;
Vicidomini, Maria .
APPLIED ENERGY, 2015, 156 :32-85
[3]   Design and partial load exergy analysis of hybrid SOFC-GT power plant [J].
Calise, F. ;
Palombo, A. ;
Vanoli, L. .
JOURNAL OF POWER SOURCES, 2006, 158 (01) :225-244
[4]   Control strategy design for a SOFC-GT hybrid system equipped with anode and cathode recirculation ejectors [J].
Chen, Jinwei ;
Li, Jingxuan ;
Zhou, Dengji ;
Zhang, Huisheng ;
Weng, Shilie .
APPLIED THERMAL ENGINEERING, 2018, 132 :67-79
[5]   Thermodynamic modeling of a gas turbine cycle combined with a solid oxide fuel cell [J].
Haseli, Y. ;
Dincer, I. ;
Naterer, G. F. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (20) :5811-5822
[6]  
Kumar S., 2008, J POWER ENERGY, V225, P1156
[7]   Modelling of gas transport phenomena in SOFC anodes [J].
Lehnert, W ;
Meusinger, J ;
Thom, F .
JOURNAL OF POWER SOURCES, 2000, 87 (1-2) :57-63
[8]   Internal reforming solid oxide fuel cell-gas turbine combined cycles (IRSOFC-GT): Part A - Cell model and cycle thermodynamic analysis [J].
Massardo, AF ;
Lubelli, F .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2000, 122 (01) :27-35
[9]  
Moradi M., 2017, ENERGY, V360
[10]   Closed-cycle gas turbine for power generation: A state-of-the-art review [J].
Olumayegun, Olumide ;
Wang, Meihong ;
Kelsall, Greg .
FUEL, 2016, 180 :694-717