Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates:: A pilot study

被引:36
作者
Zihlmann, Monika Silvia
Gerber, Hans
Stacoff, Alex
Burckhardt, Kathrin
Szekely, Gabor
Stuessi, Edgar
机构
[1] Swiss Fed Inst Technol, Biomech Lab, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Comp Vis Lab, Zurich, Switzerland
关键词
movable video-fluoroscopy; level walking; kinematics and kinetics; total knee arthroplasty; force plate data;
D O I
10.1016/j.gaitpost.2005.12.012
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The goal of the study was to simultaneously obtain accurate kinematic and kinetic data from a total knee arthroplasty (TKA) during level walking, by coupling force plate data with the kinematics of TKA measured by a movable video-fluoroscopic system. Kinematic and kinetic information of a TKA is crucial for the improvement of implant designs and for the increased longevity of the implant components. Instrumented gait analysis, with skin mounted marker tracking and force plates, is a well-established method for the acquisition of kinematic and kinetic data of TKA in vivo and for non-invasive estimation of joint function. However, resultant moments at the knee joint are inaccurate with this method, due to skin movement artifacts. Video-fluoroscopy reduces these inaccuracies by means of the direct tracking of the implant components with X-ray. However this measuring technique carries disadvantages: it provides only kinematic data, and the image intensifier covers a limited field of view. This paper presents a newly developed measuring technique, which enables a more accurate resultant moments calculation for level walking than could be achieved by conventional instrumented gait analysis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 17 条
[11]   Surface movement errors in shank kinematics and knee kinetics during gait [J].
Holden, JP ;
Orsini, JA ;
Siegel, KL ;
Kepple, TM ;
Gerber, LH ;
Stanhope, SJ .
GAIT & POSTURE, 1997, 5 (03) :217-227
[12]  
Ishii Y, 1998, J Orthop Sci, V3, P310, DOI 10.1007/s007760050058
[13]   Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects [J].
Stagni, R ;
Fantozzi, S ;
Cappello, A ;
Leardini, A .
CLINICAL BIOMECHANICS, 2005, 20 (03) :320-329
[14]   Rising from chair after total knee arthroplasty [J].
Su, FC ;
Lai, KA ;
Hong, WH .
CLINICAL BIOMECHANICS, 1998, 13 (03) :176-181
[15]   Biomechanical background and clinical observations of rotational malalignment in TKA:: Literature review and consequences [J].
Zihlmann, MS ;
Stacoff, A ;
Romero, J ;
Kramers-de Quervain, I ;
Stüssi, E .
CLINICAL BIOMECHANICS, 2005, 20 (07) :661-668
[16]  
ZIHLMANN MS, 2004, P 13 C CAN SOC BIOM
[17]   A model-based method for the reconstruction of total knee replacement kinematics [J].
Zuffi, S ;
Leardini, A ;
Catani, F ;
Fantozzi, S ;
Cappello, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :981-991