Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates:: A pilot study

被引:36
作者
Zihlmann, Monika Silvia
Gerber, Hans
Stacoff, Alex
Burckhardt, Kathrin
Szekely, Gabor
Stuessi, Edgar
机构
[1] Swiss Fed Inst Technol, Biomech Lab, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Comp Vis Lab, Zurich, Switzerland
关键词
movable video-fluoroscopy; level walking; kinematics and kinetics; total knee arthroplasty; force plate data;
D O I
10.1016/j.gaitpost.2005.12.012
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The goal of the study was to simultaneously obtain accurate kinematic and kinetic data from a total knee arthroplasty (TKA) during level walking, by coupling force plate data with the kinematics of TKA measured by a movable video-fluoroscopic system. Kinematic and kinetic information of a TKA is crucial for the improvement of implant designs and for the increased longevity of the implant components. Instrumented gait analysis, with skin mounted marker tracking and force plates, is a well-established method for the acquisition of kinematic and kinetic data of TKA in vivo and for non-invasive estimation of joint function. However, resultant moments at the knee joint are inaccurate with this method, due to skin movement artifacts. Video-fluoroscopy reduces these inaccuracies by means of the direct tracking of the implant components with X-ray. However this measuring technique carries disadvantages: it provides only kinematic data, and the image intensifier covers a limited field of view. This paper presents a newly developed measuring technique, which enables a more accurate resultant moments calculation for level walking than could be achieved by conventional instrumented gait analysis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 17 条
[1]  
Andriacchi T P, 1988, Orthop Rev, V17, P470
[2]   The use of functional analysis in evaluating knee kinematics [J].
Andriacchi, TP ;
Dyrby, CO ;
Johnson, TS .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :44-53
[3]  
[Anonymous], 1996, KNEE, DOI DOI 10.1016/0968-0160(96)00210-4
[4]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]  
BARTH E, 1978, BIOMED TECH BERL, P23
[6]  
BURCKHARDT KV, 2002, THESIS SWISS FEDERAL
[7]  
DELUZIO KJ, 2000, P 11 C CAN SOC BIOM
[8]  
FANTOZZI S, 2002, GAIT POSTURE, V15, P1
[9]   Computational wear prediction of a total knee replacement from in vivo kinematics [J].
Fregly, BJ ;
Sawyer, WG ;
Harman, MK ;
Banks, SA .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :305-314
[10]   Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy [J].
Hoff, WA ;
Komistek, RD ;
Dennis, DA ;
Gabriel, SM ;
Walker, SA .
CLINICAL BIOMECHANICS, 1998, 13 (07) :455-472