Has the Quick or the Owren prothrombin time method the advantage in harmonization for the International Normalized Ratio system?

被引:12
作者
Horsti, J [1 ]
机构
[1] Tampere Univ Hosp, Dist Hosp Valkaekoski, Valkeakoski, Finland
关键词
prothrombin time; International Normalized Ratio; International Sensitivity Index;
D O I
10.1097/00001721-200210000-00010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prothrombin time (PT) is the most commonly used coagulation test in health care. We sought here to compare two major PT methods (Quick and Owren) for harmonization of International Normalized Ratio (INR) results. We measured PT with an ACL 7000 analyser. We used three Owren and three Quick reagents for PT, and estimated the International Sensitivity Index (ISI) for each reagent using two local and two manufactured ISI calibrator sets. The coagulation time was measured using five different normal plasmas to assess variation for every reagent and both methods. We studied the analytical bias for every reagent and both methods at INR = 1.0 and INR = 2.5. The mean percentage coefficient of variation of the Owren reagent ISI was 2.40% and that of the Quick reagent ISI was 12.85%. The mean percentage coefficient of variation of normal plasma seconds for the Owren method was 2.54% and that for Quick was 4.02%. The absolute error at INR = 1.0 and INR = 2.5 was 0.00 and 0.04 INR for Owren, and 0.01 and 0.16 INR for Quick. The Owren PT method has the advantage over the Quick PT method in ISI calibration, normal plasma variation, within-run analytical variation and absolute error at INR = 2.5. The INR system is more demanding on analytical quality than earlier units (Ratio,%). The data would indicate that the Owren PT method has advantages over the Quick PT method in harmonization of the INR system. (C) 2002 Lippincott Williams Wilkins.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 50 条
  • [21] Validity of international normalized ratio in expressing prothrombin times in anticoagulated and nonanticoagulated patients
    Alshameeri, R
    Mammen, EF
    Paisley, C
    Perry, C
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 1996, 2 (01) : 25 - 29
  • [22] Changes to prothrombin international normalized ratio in patients receiving hemodialysis
    Maruyama, Noriaki
    Abe, Masanori
    Okada, Kazuyoshi
    Soma, Masayoshi
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2013, 51 (04) : 283 - 287
  • [23] Effect of isotretinoin on prothrombin time (PT), international normalized ratio (INR), and activated partial thromboplastin time (aPTT)
    Kaptanoglu, Asli Feride
    Uncu, Murat
    Ozyurt, Selcuk
    Hincal, Evren
    JOURNAL OF DERMATOLOGICAL TREATMENT, 2013, 24 (04) : 272 - 274
  • [24] Influence of plasma volumetric errors on the prothrombin time ratio and International Sensitivity Index
    vandenBesselaar, AMHP
    MeeuwisseBraun, J
    SchaefervanMansfeld, H
    Witteveen, E
    vanRijn, C
    BLOOD COAGULATION & FIBRINOLYSIS, 1997, 8 (07) : 431 - 435
  • [25] Prothrombin Time-International Normalized Ratio Predicts the Outcome of Atrial Fibrillation Patients Taking Rivaroxaban
    Chao, Tze-Fan
    Chan, Yi-Hsin
    Tsai, Pei-Chien
    Lee, Hsin-Fu
    Chang, Shang-Hung
    Kuo, Chi-Tai
    Lip, Gregory Y. H.
    Chen, Shih-Ann
    Yeh, Yung-Hsin
    BIOMEDICINES, 2022, 10 (12)
  • [26] A comparison between capillary and venous blood international normalized ratio determinations in a portable prothrombin time device
    van den Besselaar, AMHP
    Meeuwisse-Braun, J
    Schaefer-van Mansfeld, H
    van Rijn, C
    Witteveen, E
    BLOOD COAGULATION & FIBRINOLYSIS, 2000, 11 (06) : 559 - 562
  • [27] Coagulometer international sensitivity index (ISI) derivation, a rapid method using the prothrombin time/international normalized ratio (PT/INR) Line: a multicenter study
    Poller, L.
    Ibrahim, S.
    Jespersen, J.
    Pattison, A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (07) : 1379 - 1384
  • [28] The prothrombin time/international normalized ratio (PT/INR) Line: derivation of local INR with commercial thromboplastins and coagulometers - two independent studies
    Poller, L.
    Ibrahim, S.
    Keown, M.
    Pattison, A.
    Jespersen, J.
    Marun, S.
    Muntean, W.
    Aspoeck, G.
    Gallus, A. S.
    Bailleul, E.
    Wijns, W.
    Michel, T.
    Jochmans, K.
    Chatelain, B.
    Marcelis, L.
    Nijs, A. N.
    Johnston, M.
    Kynde, K.
    Syrjala, M.
    Savolainen, E. -R.
    Ivaska, K.
    Rajamaki, A.
    Vanharanta, R.
    Juhan, I.
    Aillaud, M. -F.
    Guillin, M. -C.
    Huisse, M. -G.
    Sie, P.
    Lecompte, T.
    Schmitt, Y.
    Harenberg, J.
    Plesch, W.
    Aronis, S.
    Theodossiades, G.
    Tsoukanas, B.
    Markala, D.
    Ditsa, M.
    Cahill, M.
    Madden, M.
    White, B.
    Nolan, B.
    Fitzgerald, H.
    McCarthy, D.
    Collins, B.
    Rooney, S.
    Naparstek, E.
    Palareti, G.
    Marongiu, F.
    Erba, N.
    Testa, S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (01) : 140 - 148
  • [29] Bias and uncertainty of the International Normalized Ratio determined with a whole blood point-of-care prothrombin time test device by comparison to a new International Standard for thromboplastin
    van den Besselaar, Antonius M. H. P.
    van Rijn, Claudia J. J.
    Abdoel, Charmane F.
    Cobbaert, Christa M.
    THROMBOSIS RESEARCH, 2021, 202 : 1 - 7
  • [30] How to Generate a More Accurate Laboratory-Based International Normalized Ratio: Solutions to Obtaining or Verifying the Mean Normal Prothrombin Time and International Sensitivity Index
    Favaloro, Emmanuel J.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2019, 45 (01) : 10 - 21