Absolute and relative intrasession reliability of surface EMG variables for voluntary precise forearm movements

被引:16
作者
Carius, Daniel [1 ]
Kugler, Patrick [2 ]
Kuhwald, Hans-Marten [1 ]
Wollny, Rainer [1 ]
机构
[1] Univ Halle Wittenberg, Movement Sci Grp, Dept Sport Sci, D-06120 Halle, Saxony Anhalt, Germany
[2] Univ Erlangen Nuremberg FAU, Dept Comp Sci, Pattern Recognit Lab, Digital Sports Grp, Erlangen, Bavaria, Germany
关键词
Electromyography; Reliability; Reproducibility; Variability; Sources of variation; Controlled movements; Concurrent movements; Wavelets; Intensity patterns; ISOMETRIC CONTRACTIONS; DYNAMIC CONTRACTIONS; MUSCLE FATIGUE; REPRODUCIBILITY; VARIABILITY; PARAMETERS; SHOULDER; PATTERNS; RECORDINGS; ACTIVATION;
D O I
10.1016/j.jelekin.2015.09.001
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The reliability of surface electromyography (EMG) derived parameters is of high importance, but there is distinct lack of studies concerning the reliability during dynamic contractions. Especially Amplitude, Fourier and Wavelet parameter in conjunction have not been tested so far. The interpretation of the EMG variables might be difficult because the movement itself introduces additional factors that affect its characteristics. The aim of this study was to determine the relative and absolute intrasession reliability of electromyographic (EMG) variables of selected arm muscles during concurrent precise elbow extension/flexion movements at different force levels and movement speed. Participants (all-male: n = 17, range 20-32 years) were asked to adapt to a gross-motor visuomotor tracking task (elbow extension/flexion movement) using a custom-built lever arm apparatus. After sufficient adaptation surface electromyography was used to record the electrical activity of mm. biceps brachii, brachioradialis and triceps brachii, and the signal amplitude (RMS [mu V]) and the mean frequency of the power spectrum (MNF [Hz]) were computed. Additionally Wavelet analysis was used. Relative reproducibility (intraclass correlation) for signal amplitude, mean frequency of the power spectrum and Wavelet intensity during dynamic contractions was fair to good, independent of force level and movement speed (ICC = 0.71-0.98). The amount of absolute intrasession reliability (coefficient of variation) of EMG variables depends on muscle and force level. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:860 / 869
页数:10
相关论文
共 38 条
[1]  
Araujo R C, 2000, Electromyogr Clin Neurophysiol, V40, P225
[2]   Reliability study of tibialis posterior and selected leg muscle EMG and multi-segment foot kinematics in rheumatoid arthritis associated pes planovalgus [J].
Barn, Ruth ;
Rafferty, Daniel ;
Turner, Deborah E. ;
Woodburn, James .
GAIT & POSTURE, 2012, 36 (03) :567-571
[3]   Computational principles of sensorimotor control that minimize uncertainty and variability [J].
Bays, Paul M. ;
Wolpert, Daniel M. .
JOURNAL OF PHYSIOLOGY-LONDON, 2007, 578 (02) :387-396
[4]   Sample size requirements for estimating intraclass correlations with desired precision [J].
Bonett, DG .
STATISTICS IN MEDICINE, 2002, 21 (09) :1331-1335
[5]   Test-retest reliability of wavelet - and Fourier based EMG (instantaneous) median frequencies in the evaluation of back and hip muscle fatigue during isometric back extensions [J].
Coorevits, Pascal ;
Danneels, Lieven ;
Cambier, Dirk ;
Ramon, Herman ;
Druyts, Hans ;
Karlsson, J. Stefan ;
De Moor, Georges ;
Vanderstraeten, Guy .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (05) :798-806
[6]  
Croce R, 2014, MUSCLE NERVE
[7]  
da Silva R A, 2008, Electromyogr Clin Neurophysiol, V48, P147
[8]   REPRODUCIBILITY OF THE MEAN POWER FREQUENCY OF THE SURFACE ELECTROMYOGRAM [J].
DAANEN, HAM ;
MAZURE, M ;
HOLEWIJN, M ;
VANDERVELDE, EA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1990, 61 (3-4) :274-277
[9]   Reliability of EMG measurements for trunk muscles during maximal and sub-maximal voluntary isometric contractions in healthy controls and CLBP patients [J].
Dankaerts, W ;
O'Sullivan, PB ;
Burnett, AF ;
Straker, LM ;
Danneels, LA .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (03) :333-342
[10]   Filtering the surface EMG signal: Movement artifact and baseline noise contamination [J].
De Luca, Carlo J. ;
Gilmore, L. Donald ;
Kuznetsov, Mikhail ;
Roy, Serge H. .
JOURNAL OF BIOMECHANICS, 2010, 43 (08) :1573-1579