Application of mixed-mode ultra high performance liquid chromatography to forensic drug analysis

被引:14
|
作者
Clyde, Cassandra [1 ]
Blake, Samantha [1 ]
Obrien, Stacey [1 ]
Igwilo, Ihuoma [1 ]
Lurie, Ira S. [1 ]
机构
[1] George Washington Univ, Dept Forens Sci, Washington, DC 20007 USA
关键词
HYDROPHILIC INTERACTION CHROMATOGRAPHY; LC-MS/MS ANALYSIS; MASS-SPECTROMETRY; CATHINONE DERIVATIVES; CHIRAL SEPARATION; RECREATIONAL DRUGS; LEGAL HIGHS; URINE; CYCLODEXTRIN; IDENTIFICATION;
D O I
10.1039/c5ay02206a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methodology is presented for the analysis of drugs of forensic interest employing a single column and the same solutions from two solvent reservoirs at different ratios for orthogonal reversed phase chromatographic and hydrophilic interaction liquid chromatographic separations. For the determination of the basic drugs in the SAMHSA-5 panel in urine, a 2.1 x 150 mm x 2.7 mm superficially porous dimethylpentafluorophenylpropyl (PFP) column was employed using two acetonitrile-water-ammonium formate solutions as A and B solvents for a binary pump with time of flight mass spectrometric (TOF-MS) detection. Applicable to the analysis of seized drugs, the same column and detector was used with acetonitrile-water-ammonium acetate solutions as A and B solvents for the separation of 15 controlled "bath salts". For both applications, employing mixed mode chromatography minimized ion suppression and allowed the unique identification of each analyte. Solid phase extraction (SPE) performed on a mixed mode MM1 column successfully recovered the solutes of interest with good recovery and minimum ion suppression or ion enhancement was observed for the ultra high performance liquid chromatography-TOF-MS analysis of the extracts. For the SPE sample preparation no evaporation and reconstitution step was required, with the elution solvent directly compatible with both the HILIC and RPC analysis on the same stationary phase.
引用
收藏
页码:9763 / 9772
页数:10
相关论文
共 50 条
  • [1] Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones
    Carnes, Stephanie
    O'Brien, Stacey
    Szewczak, Angelica
    Tremeau-Cayel, Lauriane
    Rowe, Walter F.
    McCord, Bruce
    Lurie, Ira S.
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (17) : 3545 - 3556
  • [2] Recent advances in materials for stationary phases of mixed-mode high-performance liquid chromatography
    Wang, Lujun
    Wei, Weili
    Xia, Zhining
    Jie, Xu
    Xia, Zeng Zilu
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 80 : 495 - 506
  • [3] Mixed-mode liquid chromatography coupled to tandem mass spectrometry for the analysis of aminoglycosides in meat
    Alechaga, Elida
    Moyano, Encarnacion
    Teresa Galceran, M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (20) : 4941 - 4953
  • [4] Preparation and evaluation a mixed-mode stationary phase with imidazolium and carboxyl group for high performance liquid chromatography
    Xian, Hong
    Peng, Huanjun
    Wang, Xiang
    Long, Dengying
    Ni, Ranxi
    Chen, Jun
    Li, Shiyu
    Zhang, Zhongying
    Peng, Jingdong
    MICROCHEMICAL JOURNAL, 2019, 150
  • [5] Mixed-mode chromatographic stationary phases: Recent advancements and its applications for high-performance liquid chromatography
    Zhang, Lu
    Dai, Qian
    Qiao, Xiaoqiang
    Yu, Chenyang
    Qin, Xinying
    Yan, Hongyuan
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 82 : 143 - 163
  • [6] Impurity profiling of drug candidates: Analytical strategies using reversed-phase and mixed-mode high-performance liquid chromatography methods
    Lemasson, Elise
    Bertin, Sophie
    Hennig, Philippe
    Lesellier, Eric
    West, Caroline
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1535 : 101 - 113
  • [7] Off-line mixed-mode liquid chromatography coupled with reversed phase high performance liquid chromatography-high resolution mass spectrometry to improve coverage in lipidomics analysis
    Narvaez-Rivas, Monica
    Ngoc Vu
    Chen, Guan-Yuan
    Zhang, Qibin
    ANALYTICA CHIMICA ACTA, 2017, 954 : 140 - 150
  • [8] Mixed-mode liquid chromatography coupled to tandem mass spectrometry for the analysis of aminoglycosides in meat
    Élida Alechaga
    Encarnación Moyano
    M. Teresa Galceran
    Analytical and Bioanalytical Chemistry, 2014, 406 : 4941 - 4953
  • [9] Mixed-mode liquid chromatography for the rapid analysis of biocatalytic glucaric acid reaction pathways
    Petroll, Kerstin
    Care, Andrew
    Waterstraat, Martin
    Bergquist, Peter L.
    Sunna, Anwar
    ANALYTICA CHIMICA ACTA, 2019, 1066 : 136 - 145
  • [10] Preparation, characterization and application of a reversed phase liquid chromatography/hydrophilic interaction chromatography mixed-mode C18-DTT stationary phase
    Wang, Qing
    Long, Yao
    Yao, Lin
    Xu, Li
    Shi, Zhi-Guo
    Xu, Lanying
    TALANTA, 2016, 146 : 442 - 451