Biodegradable scleral implant for intravitreal controlled release of ganciclovir

被引:38
|
作者
Yasukawa, T
Kimura, H
Kunou, N
Miyamoto, H
Honda, Y
Ogura, Y [1 ]
Ikada, Y
机构
[1] Nagoya City Univ, Sch Med, Dept Ophthalmol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Kyoto, Japan
[3] Kyoto Univ, Inst Frontier Med Sci, Kyoto, Japan
关键词
D O I
10.1007/s004170050031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The aims of this study were to develop biodegradable scleral implants that could overcome previously reported disadvantages such as an adverse burst in the late phase of release and to investigate the release profile of modified scleral implants in vitro and in vivo. Methods: The modified scleral implants (weight 8.5 mg, length 5 mm) were made of mixtures of poly(DL-lactide) (PLA) with different molecular weights and contained 25 weight % of ganciclovir (GCV). The release of GCV was evaluated in vitro by spectrophotometry. Intravitreal GCV concentrations in vivo were measured by high performance liquid chromatography following plug implantation in pigmented rabbits. The biocompatibility of the device was determined by indirect ophthalmoscopy and light microscopy. Results: The in vitro release studies showed stable, longterm sustained and slow release. The in vivo release studies showed that the implants had long-term release in the diffusional phase of the triphasic release pattern and only a minor adverse burst of GCV in the late phase. No significant retinal toxicity was observed by histologic examination. Conclusion: Our findings showed that this newly modified scleral implant may provide suitable intravitreal drug delivery for treatment of cytomegalovirus retinitis.
引用
收藏
页码:186 / 190
页数:5
相关论文
共 50 条
  • [1] Biodegradable scleral implant for intravitreal controlled release of ganciclovir
    T. Yasukawa
    H. Kimura
    N. Kunou
    H. Miyamoto
    Y. Honda
    Y. Ogura
    Y. Ikada
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 186 - 190
  • [2] Biodegradable scleral implant for intravitreal controlled release of fluconazole
    Miyamoto, H
    Ogura, Y
    Hashizoe, M
    Kunou, N
    Honda, Y
    Ikada, Y
    CURRENT EYE RESEARCH, 1997, 16 (09) : 930 - 935
  • [3] Biodegradable scleral implant for controlled intraocular delivery of ganciclovir
    Kunou, N
    Ogura, Y
    Hashizoe, M
    Honda, Y
    Ikada, Y
    Ota, A
    Hikida, M
    Kawashima, Y
    23RD INTERNATIONAL SYMPOSIUM ON CONTROLLED RELEASE OF BIOACTIVE MATERIALS, 1996 PROCEEDINGS, 1996, : 711 - 712
  • [4] CONTROLLED INTRAOCULAR DELIVERY OF GANCICLOVIR WITH USE OF BIODEGRADABLE SCLERAL IMPLANT IN RABBITS
    KUNOU, N
    OGURA, Y
    HASHIZOE, M
    HONDA, Y
    HYON, SH
    IKADA, Y
    JOURNAL OF CONTROLLED RELEASE, 1995, 37 (1-2) : 143 - 150
  • [5] Long-term sustained release of ganciclovir from biodegradable scleral implant for the treatment of cytomegalovirus retinitis
    Kunou, N
    Ogura, Y
    Yasukawa, T
    Kimura, H
    Miyamoto, H
    Honda, Y
    Ikada, Y
    JOURNAL OF CONTROLLED RELEASE, 2000, 68 (02) : 263 - 271
  • [6] Biodegradable polymeric device for sustained intravitreal release of ganciclovir in rabbits
    Hashizoe, M
    Ogura, Y
    Takanashi, T
    Kunou, N
    Honda, Y
    Ikada, Y
    CURRENT EYE RESEARCH, 1997, 16 (07) : 633 - 639
  • [7] BIODEGRADABLE POLYMERIC DEVICE FOR INTRAVITREAL SUSTAINED-RELEASE OF GANCICLOVIR IN RABBITS
    HASHIZOE, M
    OGURA, Y
    TAKANASHI, T
    KUNOU, N
    HONDA, Y
    IKADA, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S322 - S322
  • [8] Biodegradable scleral implant for intraocular controlled delivery of corticosteroid
    Kunou, N
    Ogura, Y
    Hashizoe, M
    Honda, Y
    Ikada, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 182 - 182
  • [9] NOVEL INJECTABLE BIODEGRADABLE POLYMER FOR CONTROLLED RELEASE OF GANCICLOVIR
    DAVIS, P
    KISS, K
    PAREL, JM
    COUSINS, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 727 - 727
  • [10] Biodegradable scleral implant for controlled intraocular delivery of betamethasone phosphate
    Kunou, N
    Ogura, Y
    Honda, Y
    Hyon, SH
    Ikada, Y
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 51 (04): : 635 - 641