Thermal-physical behavior and energy performance of air-supported membranes for sports halls: A comparison among traditional and advanced building envelopes

被引:29
作者
Suo, Hua [1 ]
Angelotti, Adriana [2 ]
Zanelli, Alessandra [1 ]
机构
[1] Politecn Milan, Architecture Built Environm & Construct Engn Dept, I-20133 Milan, Italy
[2] Politecn Milan, Dept Energy, I-20133 Milan, Italy
关键词
Textile architecture; Fabric; Membrane; Air-supported structure; Pneumatic envelope; Cushion; Dynamic simulation; AFN; Energy performance; Comfort;
D O I
10.1016/j.enbuild.2015.10.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the last decade textile architecture has become increasingly popular: fabrics and foils are more and more used as skins for permanent and enclosed buildings. The thermal-physical behavior of air-supported membrane structures, characterized by low thermal inertia and poor insulation, is definitely different from the traditional architectures, although required comfort levels are often similar. While the thermal behavior of the wider spread ETFE foil cushion system is still investigated, a quantitative assessment of the double-layered fabric skin energy performance is still lacking. This paper studies the latter membrane system, focusing on the evolution of air-supported envelopes for sports halls, from single layer to double layer membranes, either based on pneumatic cushions or on continuous air gaps. By performing measurements on running sports halls and dynamic simulations, the winter energy performance, the comfort conditions and the internal surfaces condensation risk of a typical sport hall in Northern Italy are evaluated. An insight is given into the envelopes dynamic behavior and energy balance. Double layers envelopes allow saving from 11% to 18% of the heating energy compared to single layer. Moreover, further energy saving strategies are proposed and quantified, considering low-emissivity coatings, reduction of the cracks areas, modifying indoor air set points. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 18 条
[1]  
[Anonymous], 2011, 410 CEN
[2]  
[Anonymous], 2005, 7730 CEN ISO
[3]   Multizone airflow Modeling in buildings: History and theory [J].
Axley, James .
HVAC&R RESEARCH, 2007, 13 (06) :907-928
[4]  
Bogner-Balz H., 2007, P INT TENSINET S 200
[5]  
*CEN EN, 2007, 15251 CEN
[6]  
Cockroft J.P., 1979, THESIS
[7]  
Forster Brian., 2004, European Design Guide for Tensile Surface Structures
[8]   Pneumatic skins in architecture. Sustainable trends in low positive pressure inflatable systems [J].
Gomez-Gonzalez, Alberto ;
Neila, Javier ;
Monjo, Juan .
2011 INTERNATIONAL CONFERENCE ON GREEN BUILDINGS AND SUSTAINABLE CITIES, 2011, 21 :125-132
[9]  
Harvie G. N., 1995, THESIS
[10]   Measurement and evaluation of the summer microclimate in the semi-enclosed space under a membrane structure [J].
He, Jiang ;
Hoyano, Akira .
BUILDING AND ENVIRONMENT, 2010, 45 (01) :230-242