Optimal design of high precision XY-scanner with nanometer-level resolution and millimeter-level working range

被引:68
作者
Kang, Dongwoo [2 ]
Kim, Kihyun [2 ]
Kim, Dongmin [2 ]
Shim, Jongyoup [2 ]
Gweon, Dae-Gab [2 ]
Jeong, Jaehwa [1 ]
机构
[1] Korea Univ, Dept Control & Instrumentat Engn, Chungnam 339700, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Mech Engn, Nanooptomechatron Lab, Taejon 305701, South Korea
关键词
Precision scanner; Flexure mechanism; Voice coil motor; Optimal design; STAGE; MICROSCOPY;
D O I
10.1016/j.mechatronics.2009.01.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article presents the design and performance evaluation of a compact high precision XY-scanner providing nanometer-level resolution and a millimeter-level travel range. The proposed XY-scanner is composed of a voice coil motor (VCM) and double compound linear spring flexure guide mechanism. The challenge was to determine design variables properly while simultaneously satisfying the requirements of high resolution. long working range, high response speed, and compact size, because the relationships between the design variables and the system parameters are complex. Therefore, we developed a design that would provide the optimal tradeoff in terms of design variables. The objective was to maximize the first resonant frequencies of the XY-scanner to increase response speed while limiting the size of the scanner to 100 mm x 100 mm x 50 mm. The XY-scanner was fabricated with optimally-designed values, and its performance was evaluated. From the experimental results, the first resonant frequencies of XY-scanner were 26.68 Hz for the X-axis and 22.79 Hz for the Y-axis. The measured results of the 10 nm resolution and 2 mm working range confirmed that the designed scanner could be successfully used in precision fields requiring nanometer-level resolution and millimeter-level travel range. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:562 / 570
页数:9
相关论文
共 21 条
[1]  
Bienias M, 1997, SURF INTERFACE ANAL, V25, P606, DOI 10.1002/(SICI)1096-9918(199706)25:7/8<606::AID-SIA285>3.0.CO
[2]  
2-S
[3]  
Chang SH, 1999, IEEE T ULTRASON FERR, V46, P897, DOI 10.1109/58.775656
[4]   Fine motion control of a moving stage using a piezoactuator associated with a displacement amplifier [J].
Choi, SB ;
Han, SS ;
Lee, YS .
SMART MATERIALS AND STRUCTURES, 2005, 14 (01) :222-230
[5]   Performance evaluation of precision nanopositioning devices caused by uncertainties due to tolerances using function approximation moment method [J].
Huh, JS ;
Kim, KH ;
Kang, DW ;
Gweon, DG ;
Kwak, BM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (01) :1-9
[6]   A review of atomic force microscopy imaging systems: application to molecular metrology and biological sciences [J].
Jalili, N ;
Laxminarayana, K .
MECHATRONICS, 2004, 14 (08) :907-945
[7]   Development of a novel maglev positioner with self-stabilizing property [J].
Jung, KS ;
Baek, YS .
MECHATRONICS, 2002, 12 (05) :771-790
[8]   Development of compact high precision linear piezoelectric stepping positioner with nanometer accuracy and large travel range [J].
Kang, Dongwoo ;
Lee, Moon G. ;
Gweon, Daegab .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (07)
[9]   Optimal design of a flexure hinge-based XYZ atomic force microscopy scanner for minimizing Abbe errors -: art. no. 073706 [J].
Kim, D ;
Kang, D ;
Shim, J ;
Song, I ;
Gweon, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (07)
[10]   Precision nano-alignment system using machine vision with motion controlled by piezoelectric motor [J].
Kuo, W. M. ;
Chuang, S. F. ;
Nian, C. Y. ;
Tarng, Y. S. .
MECHATRONICS, 2008, 18 (01) :21-34