ESI behavior of thiamphenicol and florfenicol in methanol and tetrahydrofuran solutions for LC-MS

被引:6
作者
Sichilougo, Kwenga [1 ]
Kolanyane, Prince [1 ]
Mazimba, Ofentse [1 ]
Masesane, Ishmael B. [1 ]
机构
[1] Univ Botswana, Dept Chem, Gaborone, Botswana
关键词
ESI; Chloramphenicol; Thiamphenicol; Florfenicol; LC-MS; NMR; ELECTROSPRAY-IONIZATION; MASS-SPECTROMETRY; CHLORAMPHENICOL; MUSCLE; IONS; MILK;
D O I
10.1016/j.ijms.2014.04.022
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Chloramphenicol (CAP) has previously been observed to be methylated off-line in solutions of methanol and acetonitrile before infusion in an electrospray ionization (ESI) source. Post-ESI studies revealed that de-solvation/de-clustering efficiency, a function of the tube lens voltage, defines spectral fidelity. We used structurally related compounds thiamphenicol (TPC) and florfenicol (FFC) herein to probe their behavior in the same context. TPC and FFC were dissolved in either deuterated methanol (CH3CD), deuterated-THF (d(8)-THF) or deuterated chloroform (CDCl3) followed by nuclear magnetic resonance (NMR) spectroscopic studies. They were also dissolved in methanol (CH3OH) and tetrahydrofuran (THF) followed by infusion into a quadrupole ion trap mass analyzer via a heated capillary and tube lens for mass spectral characteristics studies. The behavior of the charged droplets of the two analytes in the region of the tube lens was followed. NMR data showed that methylation of TPC and FFC occurred off-line in methanol but not in THF before ESI.. Enhanced mass spectral signals at optimal tube lens voltages (TLVs) were seen in THF compared to methanol. In FFC, the intensity of 356 increased by 74% at optimal TLV. In TPC, the intensity of m/z 354 increased by 54% at optimal TLV. Enhanced chloride adduct ions [M+Cl] (-) signals were favored at optimum TLVs in THF in both instances. THF proved to be a better solvent in contrast to methanol/acetonitrile due to ease of de-solvation and de-clustering. Off-line methylation of the analytes most likely at the amide nitrogen in methanol/acetonitrile is detrimental to ESI. A THF/water solvent system is highly recommended for LC-MS analysis of phenicols. (c) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 17 条
[1]  
Agilent Technologies, 2014, US TETR THF LC MS
[2]   Development of an improved method for trace analysis of chloramphenicol using molecularly imprinted polymers [J].
Boyd, Brian ;
Bjork, Henrik ;
Billing, Johan ;
Shimelis, Olga ;
Axelsson, Sara ;
Leonora, Maria ;
Yilmaz, Ecevit .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) :63-71
[3]  
Chou KY, 2009, J AOAC INT, V92, P1225
[4]   SOLVENT EFFECT ON ANALYTE CHARGE-STATE, SIGNAL INTENSITY, AND STABILITY IN NEGATIVE-ION ELECTROSPRAY MASS-SPECTROMETRY - IMPLICATIONS FOR THE MECHANISM OF NEGATIVE-ION FORMATION [J].
COLE, RB ;
HARRATA, AK .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :546-556
[5]  
Fuchs FD, 2004, FARMACOLOGIA CLIN FU
[6]  
Guy PA, 2004, J CHROMATOGR A, V1054, P365, DOI 10.1016/S0021-9673(04)01290-7
[7]  
Luo L, 2010, J CHROMATOGR B, P207
[8]   Simultaneous determination of chloramphenicol and florfenicol in liquid milk, milk powder and bovine muscle by LC-MS/MS [J].
Rezende, D. R. ;
Fleury Filho, N. ;
Rocha, G. L. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (04) :559-570
[9]   Determination of chloramphenicol, thiamphenicol, florfenicol, and florfenicol amine in poultry and porcine muscle and liver by gas chromatography-negative chemical ionization mass spectrometry [J].
Shen, Jianzhong ;
Xia, Xi ;
Jiang, Haiyang ;
Li, Cun ;
Li, Jiancheng ;
Li, Xiaowei ;
Ding, Shuangyang .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (14-15) :1523-1529
[10]   Pre-electrospray ionisation manifold methylation and post-electrospray ionisation manifold cleavage/ion cluster formation observed during electrospray ionisation of chloramphenicol in solutions of methanol and acetonitrile for liquid chromatography-mass spectrometry employing a commercial quadrupole ion trap mass analyser [J].
Sichilongo, Kwenga F. ;
Famuyiwa, Samson O. ;
Kibechu, Rose .
EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2011, 17 (03) :255-264