High-Voltage Closed-Loop Power Supply for Ozone Generators

被引:1
作者
Marcos Alonso, J. [1 ]
Ordiz, Carlos [1 ]
机构
[1] Univ Oviedo, Dept Elect Engn, Gijon 33204, Spain
关键词
OZONATION; WATER;
D O I
10.1080/09398368.2009.11463716
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper the design, implementation and experimental results of a high-voltage power supply for ozone generation are presented. The power stage arrangement is formed by a buck converter plus a current-fed parallel-resonant push-pull inverter. The back converter is used to both regulate the output power against the line voltage variation, and to control the power delivered to the ozone generator (OG). The push-pull inverter assures safe operation of the OG by working at the parallel resonant frequency given by the high-voltage transformer plus OG characteristic. The closed-loop operation of the proposed converter is analyzed and implemented as a method to compensate variations in the line voltage and in the OG. A low cost commercial UC3872 integrated circuit is used to control both the push-pull inverter and the buck converter providing OG power control and regulation via buck converter duty cycle. Protections against short circuit and no load operation are also implemented. Experimental results for a 100 W prototype are shown and discussed.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 18 条
[1]  
Alonso J. M., 2004, P IEEE APPL POW EL C
[2]   A novel control method for piezoelectric-transformer based power supplies assuring zero-voltage-switching operation [J].
Alonso, J. Marcos ;
Ordiz, Carlos ;
Costa, Marco A. Dalla .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (03) :1085-1089
[3]   Analysis, design, and experimentation of a high-voltage power supply for ozone generation based,on current-fed parallel-resonant push-pull inverter [J].
Alonso, JM ;
García, J ;
Calleja, AJ ;
Ribas, J ;
Cardesín, J .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1364-1372
[4]   High frequency testing and modeling of silent discharge ozone generators [J].
Alonso, JM ;
Valdés, M ;
Calleja, AJ ;
Ribas, J ;
Losada, J .
OZONE-SCIENCE & ENGINEERING, 2003, 25 (05) :363-376
[5]  
ALONSO JM, 2007, P IEEE IND APPL SOC
[6]   Evaluation of ozone pretreatment on flux parameters of reverse osmosis for surface water treatment [J].
Brown, Shalana L. ;
Leonard, Kathleen M. ;
Messimer, Sherri L. .
OZONE-SCIENCE & ENGINEERING, 2008, 30 (02) :152-164
[7]   Experimental results of a cost-effective ozone generator for water treatment in colombia [J].
Echeverry Ibarra, Diego Fernando ;
Cadavid Ramirez, Hector ;
Marcos Alonso, Jose ;
Aponte Mayor, Guillermo ;
Galvis Castano, Alberto .
OZONE-SCIENCE & ENGINEERING, 2008, 30 (03) :202-209
[8]   Ozonation and advanced oxidation treatment of emerging organic pollutants in water and wastewater [J].
Ikehata, Keisuke ;
Gamal El-Din, Mohamed ;
Snyder, Shane A. .
OZONE-SCIENCE & ENGINEERING, 2008, 30 (01) :21-26
[9]  
Kogelschatz U. U., 1995, HDB ELECTROSTATIC PR
[10]   Current-fed parallel-resonant dc-ac inverter for cold-cathode fluorescent lamps with zero-current switching [J].
Liang, Tsorng-Juu ;
Chen, Ren-Yi ;
Chen, Jiann-Fuh .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (04) :2206-2210