Platinum particles-modified electrode for HPLC with pulsed amperometric detection of thiols in rat striatum

被引:24
作者
Cao, XN
Li, JH
Xu, HH
Lin, L
Xian, YZ
Yamamoto, K
Jin, LT [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] BAS Co Ltd, Sumida Ku, Tokyo 131, Japan
关键词
pulsed amperometric detection; Pt particles; L-cysteine; glutathione; penicillamine; striatum;
D O I
10.1002/bmc.357
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new chemically modified electrode based on the immobilization of Pt particles is fabricated and exhibits electrocatalytic oxidation for L-cysteine (L-Cys), glutathione (GSH) and penicillamine (PEN) with relatively high sensitivity. It is also adaptable to HPLC for pulsed amperometric detection (PAD) of these thiols. PAD largely improves the detection sensitivity because the alternated polarizations can effectively clean and reactivate the electrode surface. It is shown that the peak currents Of L-CYS, GSH and PEN are linear to their concentrations, with the calculated detection limit of 1.1x10(-7), 1.8x10(-7) and 3.8x10(-7) mol L-1. respectively (S/N=3). The method has been successfully applied to assess the contents Of L-Cys and GSH in rat striatal microdialysates. The average contents of the two analytes in rat striatum are 2.6x10(-6) and 2.8x10(-6) mol L-1, respectively. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:564 / 569
页数:6
相关论文
共 42 条
  • [1] Pulsed amperometric detection of DNA with an ssDNA/polypyrrole-modified electrode
    Almira Ramanaviciene
    Arunas Ramanavicius
    Analytical and Bioanalytical Chemistry, 2004, 379 : 287 - 293
  • [2] Pulsed amperometric detection of DNA with an ssDNA/polypyrrole-modified electrode
    Ramanaviciene, A
    Ramanavicius, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (02) : 287 - 293
  • [3] Quantification of Alpha Lipoic Acid in Pharmaceutical Products by HPLC with Pulsed Amperometric Detection at a Gold Electrode
    Viana, Carine
    Ribeiro, Sandra M.
    Moreira, Ana P. L.
    Mueller, Larissa S.
    Motta, Monique J.
    Monserrat, Jose M.
    de Carvalho, Leandro M.
    Bohrer, Denise
    CURRENT ANALYTICAL CHEMISTRY, 2019, 15 (06) : 694 - 700
  • [4] DETERMINATION OF CYSTEINE AND REDUCED GLUTATHIONE IN HUMAN PLASMA BY LIQUID-CHROMATOGRAPHY WITH PULSED AMPEROMETRIC ELECTROCHEMICAL DETECTION USING A PLATINUM-PARTICLES MODIFIED GLASSY-CARBON ELECTRODE
    LIU, AH
    LI, T
    WANG, EK
    ANALYTICAL SCIENCES, 1995, 11 (04) : 597 - 603
  • [5] Amperometric detection of organic thiols at a tungsten wire electrode following their separation by liquid chromatography
    Hidayat, A
    Hibbert, DB
    Alexander, PW
    JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01): : 139 - 146
  • [6] Amperometric sensor for thiols based on mechanically immobilised nickel hexacyanoferrate modified electrode
    Shankaran, DR
    Narayanan, SS
    BULLETIN OF ELECTROCHEMISTRY, 2001, 17 (06): : 277 - 280
  • [7] Determination of thiols following their separation by CZE with amperometric detection at a carbon electrode
    Wang, A
    Zhang, L
    Zhang, S
    Fang, Y
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (2-3) : 429 - 436
  • [8] Activated pulsed amperometric detection of cysteine at platinum electrodes in acidic media
    Johll, ME
    Williams, DG
    Johnson, DC
    ELECTROANALYSIS, 1997, 9 (18) : 1397 - 1402
  • [9] HPLC method validation for Digitalis and its analogue by pulsed amperometric detection
    Kwon, Ha-Jeong
    Sim, Hee-Jung
    Lee, Sa-im
    Lee, Yong-Moon
    Park, Yong-Duk
    Hong, Seon-Pyo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 217 - 221
  • [10] Detection of monoamines in rat striatum with microbore HPLC-ECD
    Wang, L
    Han, HW
    Yu, X
    Zhao, R
    Liu, GQ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2002, 23 (06): : 1050 - 1052