Thermal comfort of different displacement ventilation systems in an aircraft passenger cabin

被引:30
作者
Maier, Julia [1 ]
Marggraf-Micheel, Claudia [1 ]
Dehne, Tobias [2 ]
Bosbach, Johannes [2 ]
机构
[1] German Aerosp Ctr, Aviat & Space Psychol, Hamburg, Germany
[2] German Aerosp Ctr, Inst Aerodynam & Flow Technol, Gottingen, Germany
关键词
Displacement ventilation; Mixing ventilation; Aircraft passenger cabin; Thermal comfort; Empirical data;
D O I
10.1016/j.buildenv.2016.11.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Of current interest is the question whether ordinary mixing ventilation (MV) systems in an aircraft can be replaced by or combined with displacement ventilation (DV) systems without risking a decrease in thermal comfort. A reduction of energy consumption is a valuable gain. Three different versions of DV were analysed employing the Do 728 cabin test facility of the German Aerospace Center as cabin environment. Three human subject tests were carried out using 40 participants each: They aimed at analysing the thermal comfort of a) 100% DV, b) a 70:30% hybrid system combining DV and MV and c) a 50:50% hybrid system of DV and MV. Objective and subjective data were gathered to gain a differentiated image of the climate situation. Results were compared with results for MV that were obtained from an earlier study. Measurement data revealed a clear vertical temperature gradient for the DV systems; the relatively smallest temperature difference between feet and head was found for 100% DV and MV. Air velocity was lower in DV and increased with the amount of mixing ventilation that was provided. Regarding subjective sensations, thermal comfort was given in all three DV systems. The overall satisfaction with the climate tended to be highest in the 50:50 hybrid system. In summary, our results demonstrate that displacement ventilation can be used to provide a comfortable climate in an aircraft cabin. Known constraints of DV as e.g. large vertical temperature differences did not have any negative influence on climate comfort ratings of the passengers. (C)2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:256 / 264
页数:9
相关论文
共 20 条
[1]  
[Anonymous], 2005, ERGONOMICS THERMAL E
[2]  
BOSBACH J, 2012, C P 28 INT C AER SCI
[3]  
Bosbach Johannes, 2013, CEAS Aeronaut, V4, P301, DOI DOI 10.1007/s13272-013-0074-z
[4]  
Hair J.F., 2006, A primer on partial least squares structural equation modeling (PLS-SEM), V6th ed.
[5]   Comparison of performances of displacement and mixing ventilations. Part I: thermal comfort [J].
Lin, Z ;
Chow, TT ;
Fong, KF ;
Wang, QW ;
Li, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02) :276-287
[6]  
MAIKWART M, 2010, SYSTEM METHOD AIR CO
[7]   Transmission of infectious diseases during commercial air travel [J].
Mangili, A ;
Gendreau, MA .
LANCET, 2005, 365 (9463) :989-996
[8]   Impact of scaling and body movement on contaminant transport in airliner cabins [J].
Mazumdar, Sagnik ;
Poussou, Stephane B. ;
Lin, Chao-Hsin ;
Isukapalli, Sastry S. ;
Plesniak, Michael W. ;
Chen, Qingyan .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (33) :6019-6028
[9]   Field study on occupant comfort and the office thermal environment in rooms with displacement ventilation [J].
Melikov, A ;
Pitchurov, G ;
Naydenov, K ;
Langkilde, G .
INDOOR AIR, 2005, 15 (03) :205-214
[10]  
MULLER D, 2011, C P WORKSH AV SYST T