Analysis of non-linear ion drift in spectrometers of ion mobility increment with cylindrical drift chamber

被引:4
|
作者
Elistratov, A. A. [1 ]
Shibkov, S. V.
Nikolaev, E. N.
机构
[1] Inst Cryptosyst Commun & Informat, Moscow, Russia
[2] Russian Acad Sci, Inst Chem Phys Energy Problems, Moscow V71, Russia
关键词
ion mobility; theory; FAIMS; differential ion mobility;
D O I
10.1255/ejms.796
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A model for the drift of ions under a non-uniform, high-frequency electric field in the drift chamber of a spectrometer of ion mobility increment is developed. For the general dependence of the ion mobility on the electric field strength and the general time-dependence of the separating voltage, we suggest a procedure for calculating of the ion peak form. The shape of the peak for the ion focusing and defocusing conditions has been obtained.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [1] Space charge effect in spectrometers of ion mobility increment with a cylindrical drift chamber
    Elistratov, A. A.
    Sherbakov, L. A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (04) : 259 - 272
  • [2] Space charge effect in spectrometers of ion mobility increment with planar drift chamber
    Elistratov, A. A.
    Sherbakov, L. A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (02) : 115 - 123
  • [3] Necessary conditions for peak resolution in an ion mobility increment spectrometer with a flat drift chamber
    S. V. Shibkov
    A. A. Elistratov
    L. A. Shcherbakov
    Technical Physics Letters, 2008, 34 : 714 - 717
  • [4] Necessary conditions for peak resolution in an ion mobility increment spectrometer with a flat drift chamber
    Shibkov, S. V.
    Elistratov, A. A.
    Shcherbakov, L. A.
    TECHNICAL PHYSICS LETTERS, 2008, 34 (08) : 714 - 717
  • [5] Conservation of the Charge in Signal from Drift Tube Ion Mobility Spectrometers
    Wolanska, Izabela
    Piwowarski, Krzysztof
    Puton, Jaroslaw
    ANALYTICAL CHEMISTRY, 2024, 96 (43) : 17337 - 17344
  • [6] LOCAL THEORY OF NON-LINEAR ION DYNAMICS IN DRIFT-CYCLOTRON WAVES
    COHEN, BI
    MARON, N
    SMITH, GR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (07): : 794 - 794
  • [7] Novel ion drift tube for high-performance ion mobility spectrometers based on a composite material
    Ahrens, Andre
    Moehle, Janina
    Hitzemann, Moritz
    Zimmermann, Stefan
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2020, 23 (02) : 75 - 81
  • [8] Augmenting Ion Trap Mass Spectrometers Using a Frequency Modulated Drift Tube Ion Mobility Spectrometer
    Morrison, Kelsey A.
    Siems, William F.
    Clowers, Brian H.
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 3121 - 3129
  • [9] An analytical model for the optimum drift voltage of drift tube ion mobility spectrometers with respect to resolving power and detection limits
    Kirk, Ansgar T.
    Zimmermann, Stefan
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2015, 18 (3-4) : 129 - 135
  • [10] NON-LINEAR DRIFT WAVES
    TANIUTI, T
    HASEGAWA, A
    PHYSICA SCRIPTA, 1982, T2 : 529 - 533