Previous studies have showed that radio-frequency plasma deposited tetraglyme coatings greatly reduced fibrinogen adsorption (Gamma(Fg)) from highly diluted plasmas (0.1 and 1%) and subsequent platelet adhesion under static conditions. In this study, the protein resistant properties of tetraglyme were re-examined with high-concentration plasma, and subsequent platelet adhesion was measured under both static and flow conditions. The resistance of tetraglyme to vWf adsorption (Gamma(vWf)) and the role of vWf in platelet adhesion under flow were also investigated. Gamma(Fg) and Gamma(vWf) were measured with I-125 radiolabeled proteins. Flow Studies were done at shear rates of 50 or 500 s(-1) by passing a platelet/red cell suspension through a GlycoTech flow chamber. When adsorbed from a series of increasing plasma concentrations, the adsorption of both proteins to tetraglyme increased steadily, and did not show a peak at intermediate dilutions, i.e., there was no Vroman effect. When plasma concentration was less than 10%, the tetraglyme surface was highly nonfouling, exhibiting ultralow Gamma(Fg) (less than 5 ng/cm(2)) and extremely low platelet adhesion under both static and flow conditions. However, when the adsorption was done from 100% plasma, Gamma(Fg) was much higher (similar to 85 ng/cm(2)), indicating that tetraglyme surface may not be sufficiently protein-resistant in the physiological environment. To correlate platelet adhesion under flow with Gamma(Fg) and Gamma(vWf), a series of tetraglyme surfaces varying in ether content and protein adsorption was created by varying deposition power. On these surfaces, platelet adhesion at low shear rate depended only on the amount of Gamma(Fg), but under high shear, both Gamma(Fg) and Gamma(vWf) affected platelet adhesion. In particular, it was found that Gamma(vWf) Must be reduced to less than 0.4 ng/cm(2) to achieve ultra low platelet adhesion under high shear. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res 89A: 791-803, 2009
引用
收藏
页码:791 / 803
页数:13
相关论文
共 21 条
  • [1] Fibrinogen and von Willebrand factor mediated platelet adhesion to polystyrene under flow conditions
    Zhang, Min
    Wu, Yuguang
    Hauch, Kip
    Horbett, Thomas A.
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2008, 19 (10) : 1383 - 1410
  • [2] Platelet adhesion to von Willebrand Factor under fluctuating flow conditions
    Zhao, Xiao-Min
    Wu, Ya-Ping
    Han, Ji-Ju
    Jiao, Peng
    Chen, Bin
    Wang, Xin-Nong
    Xia, Zuo-Li
    ACTA PHARMACOLOGICA SINICA, 2006, 27 : 176 - 176
  • [3] Fibrinogen and von Willebrand's factor adsorption are both required for platelet adhesion from sheared suspensions to polyethylene preadsorbed with blood plasma
    Kwak, D
    Wu, YG
    Horbett, TA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 74A (01) : 69 - 83
  • [4] Effect of adsorbed von Willebrand factor and fibrinogen on platelet interactions with synthetic materials under flow conditions
    Wu, Yuguang
    Zhang, Min
    Hauch, Kip D.
    Horbett, Thomas A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 85A (03) : 829 - 839
  • [5] Evaluation of the Effect of 6 von Willebrand Factor Concentrates on Platelet Adhesion to Human Vein Segments under Flow Conditions
    Wolfgang Mouton
    Jerzy Madon
    Joerg Fehr
    Thomas Bombeli
    International Journal of Hematology, 2004, 80 : 383 - 385
  • [6] Testing of platelet deposition on polystyrene surface under flow conditions by the cone and plate(let) analyzer: Role of platelet activation, fibrinogen and von Willebrand factor
    Shenkman, B
    Savion, N
    Dardik, R
    Tamarin, I
    Varon, D
    THROMBOSIS RESEARCH, 2000, 99 (04) : 353 - 361
  • [7] Distinct Role of von Willebrand Factor Triplet Bands in Glycoprotein Ib-Dependent Platelet Adhesion and Thrombus Formation under Flow
    Fuchs, Birte
    de Witt, Susanne
    Solecka, Barbara A.
    Kroening, Mario
    Obser, Tobias
    Cosemans, Judith M. E. M.
    Schneppenheim, Reinhard
    Heemskerk, Johan W. M.
    Kannicht, Christoph
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2013, 39 (03) : 306 - 314
  • [8] Evaluation of von Willebrand factor concentrates by platelet adhesion to collagen using an in vitro flow assay
    Riddell, Anne
    Vinayagam, Saravanan
    Gomez, Keith
    Laffan, Mike
    McKinnon, Tom
    RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2019, 3 (01) : 126 - 135
  • [9] Platelet adhesion to polystyrene-based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand's factor
    Tsai, WB
    Grunkemeier, JM
    McFarland, CD
    Horbett, TA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 60 (03): : 348 - 359
  • [10] Modification of human platelet adhesion on biomaterial surfaces by protein preadsorption under static and flow conditions
    Mike Otto
    Arno Franzen
    Torsten Hansen
    Charles James Kirkpatrick
    Journal of Materials Science: Materials in Medicine, 2004, 15 : 35 - 42