Non-invasive high frequency oscillatory ventilation inhibiting respiratory motion in healthy volunteers

被引:0
|
作者
Zhang, Yanshan [1 ]
Li, Xiaojun [1 ]
Zhang, Yihe [1 ]
Ye, Yancheng [1 ]
Jen, Yee-Min [1 ,2 ]
Pan, Xin [1 ]
Li, Xiaowei [1 ]
Qin, Tianyan [1 ]
Li, Pengqing [1 ]
Lv, Caixia [1 ]
Qi, Ying [1 ]
Wang, Xin [1 ]
Yang, Yuling [1 ]
Ma, Tong [1 ]
机构
[1] Wuwei Canc Hosp, Heavy Ion Ctr, 31 Sanit Lane,Haizang Rd, Wuwei 733000, Gansu, Peoples R China
[2] Yee Zen Gen Hosp, Dept Radiat Oncol, 30 Yangxing North Rd, Taoyuan, Taiwan
关键词
JET VENTILATION; RADIATION-THERAPY; MANAGEMENT; RADIOTHERAPY; LUNG; REDUCTION;
D O I
10.1038/s41598-022-27288-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Precision radiotherapy needs to manage organ movements to prevent critical organ injury. The purpose of this study is to examine the feasibility of motion control of the lung by suppressing respiratory motion. The non-invasive high frequency oscillatory ventilation (NIHFOV) is a technique commonly used in the protection of lung for patients with acute lung disease. By using a very high respiratory frequency and a low tidal volume, NIHFOV allows gas exchange, maintains a constant mean airway pressure and minimizes the respiratory movements. We tested healthy volunteers NIHFOV to explore the optimal operational parameter setting and the best possible motion suppression achievable. This study was conducted with the approval of Institutional Review Boards of the Wuwei Cancer hospital (approval number: 2021-39) and carried out in accordance with Declaration of Helsinki. The study comprises two parts. Twenty three healthy volunteers participated in the first part of the study. They had 7 sessions of training with the NIHFOV. The duration of uninterrupted, continuous breathing under the NIHFOV and the optimal operational machine settings were defined. Eight healthy volunteers took part in the second part of the study and underwent 4-dimensional CT (4DCT) scanning with and without NIHFOV. Their respiratory waveform under free breathing (FB) and NIHFOV were recorded. The maximum range of motion of the diaphragm from the two scannings was compared, and the variation of bilateral lung volume was obtained to evaluate the impact of NIHFOV technique on lung volume. The following data were collected: comfort score, transcutaneous partial pressure of oxygen (PtcO(2)), transcutaneous partial pressure of carbon dioxide (PtcCO(2)), and pulse rate. Data with and without NIHFOV were compared to evaluate its safety, physiological impacts and effect of lung movement suppression. All the volunteers completed the training sessions eventlessly, demonstrating a good tolerability of the procedure. The median NIHFOV-on time was 32 min (22-45 min), and the maximum range of motion in the cephalic-caudal direction was significantly reduced on NIHFOV compared with FB (1.8 +/- 0.8 cm vs 0.3 +/- 0.1 cm, t=-3.650, P=0.003); the median range of motion was only 0.3 +/- 0.1 cm on NIHFOV with a good reproducibility. The variation coefficient under NIHFOV of the right lung volume was 2.4% and the left lung volume was 9.2%. The PtcO(2) and PtcCO(2) were constantly monitored during NIHFOV. The medium PtcCO(2) under NIHFOV increased lightly by 4.1 mmHg (interquartile range [IQR], 4-6 mmHg) compared with FB (t=17.676, P<0.001). No hypercapnia was found, PtcO(2) increased significantly in all volunteers during NIHFOV (t=25.453, P<0.001). There was no significant difference in pulse rate between the two data sets (t=1.257, P=0.233). NIHFOV is easy to master in healthy volunteers to minimize respiratory movement with good tolerability and reproducibility. It is a feasible approach for lung motion control and could potentially be applied in accurate radiotherapy including carbon-ion radiotherapy through suppression of respiratory movement.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] High-Frequency Oscillatory Ventilation: The Devil May Be in the Details
    Willson, Douglas F.
    RESPIRATORY CARE, 2014, 59 (02) : 297 - 298
  • [32] Identification of optimal lung volume during high-frequency oscillatory ventilation using respiratory inductive plethysmography
    Brazelton, TB
    Watson, KF
    Murphy, M
    Al-Khadra, E
    Thompson, JE
    Arnold, JH
    CRITICAL CARE MEDICINE, 2001, 29 (12) : 2349 - 2359
  • [33] Advances in Non-invasive Respiratory Support in the ICU.
    Pons Odena, Marti
    PEDIATRIC PULMONOLOGY, 2018, 53 : S34 - S35
  • [34] Non-invasive respiratory support in elderly hospitalized patients
    Coppola, Silvia
    Radovanovic, Dejan
    Pozzi, Tommaso
    Danzo, Fiammetta
    Rocco, Cosmo
    Lazzaroni, Giada
    Santus, Pierachille
    Chiumello, Davide
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2024, 18 (10) : 789 - 804
  • [35] Early non-invasive ventilation treatment for severe influenza pneumonia
    Masclans, J. R.
    Perez, M.
    Almirall, J.
    Lorente, L.
    Marques, A.
    Socias, L.
    Vidaur, L.
    Rello, J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2013, 19 (03) : 249 - 256
  • [36] The changing landscape of non-invasive ventilation in amyotrophic lateral sclerosis
    Bourke, Stephen C.
    O'Neill, Catherine L.
    Williams, Tim L.
    Peel, Edwin T.
    Gibson, G. John
    Mc Dermott, Christopher J.
    Shaw, Pamela J.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2012, 83 (04): : 368 - 369
  • [37] Predictors of non-invasive ventilation tolerance in amyotrophic lateral sclerosis
    Volanti, Paolo
    Cibella, Fabio
    Sarva, Maria
    De Cicco, Domenico
    Spanevello, Antonio
    Mora, Gabriele
    La Bella, Vincenzo
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2011, 303 (1-2) : 114 - 118
  • [38] Use of non-invasive ventilation in children with congenital tracheal stenosis
    Pellen, G.
    Pandit, C.
    Castro, C.
    Robinson, P.
    Seton, C.
    Fitzgerald, D. A.
    Waters, K.
    Cheng, A. T.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 127
  • [39] Acidosis, non-invasive ventilation and mortality in hospitalised COPD exacerbations
    Roberts, C. M.
    Stone, R. A.
    Buckingham, R. J.
    Pursey, N. A.
    Lowe, D.
    THORAX, 2011, 66 (01) : 43 - 48
  • [40] Non-invasive mechanical ventilation with spinal anesthesia for cesarean delivery
    Erdogan, G.
    Okyay, D. Z.
    Yurtlu, S.
    Hanci, V.
    Ayoglu, H.
    Koksal, B.
    Turan, I. O.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2010, 19 (04) : 438 - 440