Reconstruction of time-varying 3-D left-ventricular shape from multiview X-ray cineangiocardiograms

被引:19
作者
Moriyama, M
Sato, Y
Naito, H
Hanayama, M
Ueguchi, T
Harada, T
Yoshimoto, F
Tamura, S
机构
[1] Osaka Univ, Div Interdisciplinary Image Anal, Dept Med Robot & Image Sci, Grad Sch Med, Suita, Osaka 5650871, Japan
[2] Osaka Int Univ, Fac Management & Informat Sci, Hirakata, Osaka, Japan
[3] Natl Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5650871, Japan
[4] Osaka Univ Hosp, Dept Radiol, Suita, Osaka 5650871, Japan
[5] Wakayama Univ, Dept Comp & Commun Sci, Wakayama 6408510, Japan
[6] Osaka Univ, Div Interdisciplinary Image Anal, Dept Med Robot & Image Sci, Grad Sch Med, Suita, Osaka 5650871, Japan
关键词
arterial septal defect (ASD); B-spline; left ventricle; multiview; time-varying closed surface; X-ray cineangiocardiogram;
D O I
10.1109/TMI.2002.801161
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper reports on the clinical application of a system for recovering the time-varying three-dimensional (3-D) left-ventricular (LV) shape from multiview X-ray cineangiocardiograms. Considering that X-ray cineangiocardiography is still commonly employed in clinical cardiology and computational costs for 3-D recovery and visualization are rapidly decreasing, it is meaningful to develop a clinically applicable system for 3-D LV shape recovery from X-ray cineangiocardiograms. The system is based on a previously reported closed-surface method of shape recovery from two-dimensional occluding contours with multiple views. To apply the method to "real" LV cineangiocardiograms, user-interactive systems were implemented for preprocessing, including detection of LV contours, calibration of the imaging geometry, and setting of the LV model coordinate system. The results for three real LV angiographic image sequences are presented, two with fixed multiple views (using supplementary angiography) and one with rotating views. 3-D reconstructions utilizing different numbers of views were compared and evaluated in terms of contours manually traced by an experienced radiologist. The performance of the preprocesses was also evaluated, and the effects of variations in user-specified parameters on the final 3-D reconstruction results were shown to be sufficiently small. These experimental results demonstrate the potential usefulness of combining multiple views for 3-D recovery from "real" LV cineangiocardiograms.
引用
收藏
页码:773 / 785
页数:13
相关论文
共 19 条
[1]   Accuracy and precision of angiographic volumetry methods for left and right ventricle [J].
Beier, J ;
Wellnhofer, E ;
Oswald, H ;
Fleck, E .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 53 (02) :179-188
[2]  
BESL EJ, P ICCV 88 TAMP FL, P591
[3]   Estimation and detection of myocardial tags in MR image without user-defined myocardial contours [J].
Denney, TS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (04) :330-344
[4]   Optimal polyline tracking for artery motion compensation in coronary angiography [J].
Dubuisson-Jolly, MP ;
Liang, CC ;
Gupta, A .
SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, :414-419
[5]  
EIHO S, P MED 1980 TOK JAP, P1093
[6]  
EIHO S, 1984, P COMP CARD, P63
[7]  
Forsey D, 1998, GRAPHICS INTERFACE '98 - PROCEEDINGS, P57
[8]   Three-dimensional modeling for functional analysis of cardiac images: A review [J].
Frangi, AF ;
Niessen, WJ ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :2-25
[9]   LEFT VENTRICULAR VOLUMES BY ANGIOCARDIOGRAPHY - COMPARISON OF METHODS AND SIMPLIFICATION OF TECHNIQUES [J].
HERMANN, HJ ;
BARTLE, SH .
CARDIOVASCULAR RESEARCH, 1968, 2 (04) :404-&
[10]  
Kachelriess M, 2000, IEEE T MED IMAGING, V19, P888, DOI 10.1109/42.887837