Exploiting dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) for sequential determination of trace elements in blood using a dilute-and-shoot procedure

被引:111
作者
Batista, Bruno Lemos [1 ]
Rodrigues, Jairo Lisboa [1 ]
Nunes, Juliana Andrade [1 ]
de Oliveira Souza, Vanessa Cristina [1 ]
Barbosa, Fernando, Jr. [1 ]
机构
[1] Univ Sao Paulo, FCFRP, Dept Anal Clin Toxicol & Bromatol, BR-14040903 Ribeirao Preto, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Trace elements; Interferences; Inductively coupled plasma mass spectrometry; Direct analysis; Clinical specimens; Dynamic reaction cell; ATOMIC-ABSORPTION-SPECTROMETRY; WHOLE-BLOOD; MULTIELEMENT ANALYSIS; TOTAL MERCURY; URINE; SERUM; CADMIUM; LEAD; RH; COINJECTION;
D O I
10.1016/j.aca.2009.03.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma mass spectrometry with quadrupole (q-ICP-MS) and dynamic reaction cell (DRC-ICP-MS) were evaluated for sequential determination of As, Cd, Co, Cr, Cu, Mn, Pb, Se, Tl, V and Zn in blood. The method requires as little as 100 mu L of blood. Prior to analysis, samples (100 mu L) were diluted 1:50 in a solution containing 0.01% (v/v) Triton (R) X-100 and 0.5% (v/v) nitric acid. The use of the DRC was only mandatory for Cr, Cu, V and Zn. For the other elements the equipment may be operated in a standard mode (q-ICP-MS). Ammonia was used as reaction gas. Selection of best flow rate of ammonium gas and optimization of the quadrupole dynamic band-pass tuning parameter (RPq) were carried out, using a ovine base blood for Cr and V and a synthetic matrix solution (SMS) for Zn and Cu diluted 1:50 and spiked to contain 1 mu g L-1 of each element. Method detection limits (3 s) for As-75, Cd-114, Co-59, Cr-51, Cu-63 Mn-55, Pb-208, Se-82, Tl-205, V-51, and Zn-64 were 14.0, 3.0, 11.0, 7.0, 280, 9.0, 3.0, 264, 0.7, 6.0 and 800 ng L-1, respectively. Method validation was accomplished by the analysis of blood Reference Materials produced by the National cle Sant Publique du Quebec (Canada). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 26 条
  • [1] Mathematical model of chloride concentration in human blood
    Amer, M.M.B.
    [J]. Journal of Medical Engineering and Technology, 2006, 30 (01) : 25 - 30
  • [2] Trace element levels in whole blood and serum from Swedish adolescents
    Bárány, E
    Bergdahl, IA
    Bratteby, LE
    Lundh, T
    Samuelson, G
    Schütz, A
    Skerfving, S
    Oskarsson, A
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2002, 286 (1-3) : 129 - 141
  • [3] Trace elements in blood and serum of Swedish adolescents:: Relation to gender, age, residential area, and socioeconomic status
    Bárány, E
    Bergdahl, IA
    Bratteby, LE
    Lundh, T
    Samuelson, G
    Schütz, A
    Skerfving, S
    Oskarsson, A
    [J]. ENVIRONMENTAL RESEARCH, 2002, 89 (01) : 72 - 84
  • [4] Inductively coupled plasma mass spectrometry for direct multi-element analysis of diluted human blood and serum
    Barany, E
    Bergdahl, IA
    Schutz, A
    Skerfving, S
    Oskarsson, A
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) : 1005 - 1009
  • [5] Determination of total mercury in whole blood by flow injection cold vapor atomic absorption spectrometry with room temperature digestion using tetramethylammonium hydroxide
    Barbosa, F
    Palmer, CD
    Krug, FJ
    Parsons, PJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) : 1000 - 1005
  • [6] Evaluation of the use of salivary lead levels as a surrogate of blood lead or plasma lead levels in lead exposed subjects
    Barbosa, Fernando, Jr.
    Heloisa, Maria
    Rodrigues, Correa
    Buzalaf, Maria R.
    Krug, Francisco J.
    Gerlach, Raquel F.
    Tanus-Santos, Jose Eduardo
    [J]. ARCHIVES OF TOXICOLOGY, 2006, 80 (10) : 633 - 637
  • [7] Determination of trace elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry - Developing of a method with a desolvating system nebulizer
    D'Ilio, S.
    Violante, N.
    Caimi, S.
    Di Gregorio, M.
    Petrucci, F.
    Senofonte, O.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 573 : 432 - 438
  • [8] Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with a high-efficiency sample introduction system
    D'Ilio, S.
    Violante, N.
    Di Gregorio, M.
    Senofonte, O.
    Petrucci, F.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 579 (02) : 202 - 208
  • [9] Practical and quality-control aspects of multi-element analysis with quadrupole ICP-MS with special attention to urine and whole blood
    de Boer, JLM
    Ritsema, R
    Piso, S
    van Staden, H
    van den Beld, W
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (5-6) : 872 - 880
  • [10] Precise and accurate determination of calcium isotope ratios in urine using HR-ICP-SFMS
    Field, MP
    Shapses, S
    Cifuentes, M
    Sherrell, RM
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (07) : 727 - 733