Compliance calibration for fatigue crack propagation testing of ultra high molecular weight polyethylene

被引:18
作者
Varadarajan, Ravikumar [1 ]
Rimnac, Clare M. [1 ]
机构
[1] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Musculoskeletal Mech & Mat Labs, Cleveland, OH 44106 USA
关键词
UHMWPE; fatigue crack propagation; polyethylene; mechanical properties; compliance calibration;
D O I
10.1016/j.biomaterials.2006.05.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultra High Molecular Weight Polyethylene (UHMWPE) total joint replacement components under certain conditions are at risk of fatigue fracture. Thus, the fatigue crack inception/propagation resistance of UHMWPE is of interest. During fatigue crack propagation tests of UHMWPE, crack growth is often followed visually; however, this approach can be time consuming and requires that the specimen be accessible during testing. The objective of this study was to demonstrate the applicability of the compliance method for fatigue crack propagation tests of UHMWPE. We hypothesized that the standard calibration coefficients developed for metals may not be appropriate for UHMWPE and that different UHMWPE materials would require different compliance calibration coefficients. Three UHMWPE materials: sterilized (30 kGy); highly crosslinked and annealed (100 kGy, 130 degrees C); and highly crosslinked and remelted (100 kGy, 150 degrees C) were examined under ambient conditions. The results support the applicability of the compliance method for determination of crack length during fatigue crack propagation testing of UHMWPE. As hypothesized, the standard calibration coefficients were found to be inaccurate for UHMWPE. New UHMWPE-specific calibration coefficients were determined which predicted the crack growth behavior accurately. Also, as hypothesized, the compliance calibration coefficients for the three materials were significantly different. This is the first reported study to demonstrate the applicability of a compliance method to measure crack length in UHMWPE. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4693 / 4697
页数:5
相关论文
共 19 条
[1]  
ASTM, 2000, ASTM E647-00
[2]  
*ASTM, 2001, 182001 ASTM E
[3]   Compression and tension fatigue resistance of medical grade ultra high molecular weight polyethylene: the effect of morphology, sterilization, aging and temperature [J].
Baker, DA ;
Hastings, RS ;
Pruitt, L .
POLYMER, 2000, 41 (02) :795-808
[4]   The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene [J].
Baker, DA ;
Bellare, A ;
Pruitt, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :146-154
[5]  
Callaghan JJ, 2002, ORTHOPEDICS, V25, P977
[6]  
DAPP EX, 1999, THESIS CASE W RESERV
[7]   Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene [J].
Gencur, SJ ;
Rimnac, CM ;
Kurtz, SM .
BIOMATERIALS, 2006, 27 (08) :1550-1557
[8]  
KAPP JA, 1991, J TEST EVAL, V19, P45, DOI 10.1520/JTE12529J
[9]  
Kleinbaum DG., 1988, APPL REGRESSION ANAL, P369
[10]  
Kurtz S.M., 2004, The UHMWPE handbook