Contact Lens Lipid Spoliation of Hydrogel and Silicone Hydrogel Lenses

被引:14
作者
Maissa, Cecile [1 ,2 ]
Guillon, Michel [1 ]
Cockshott, Nik [1 ]
Garofalo, Renee J. [2 ]
Lemp, Jessie M. [2 ]
Boclair, Joseph W. [2 ]
机构
[1] OTG Res & Consultancy, London, England
[2] Alcon Labs Inc, Ft Worth, TX 76134 USA
关键词
lipid uptake; daily wear; extended wear; etafilcon A; balafilcon A; TEAR FILM LIPIDS; IN-VITRO; GROUP-II; DEPOSITION; QUANTIFICATION; PROTEIN; CHOLESTEROL;
D O I
10.1097/OPX.0000000000000341
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of the study was to measure contact lens lipid spoliation of silicone hydrogel PureVision (balafilcon A) and hydrogel Acuvue 2 (etafilcon A) contact lenses worn for 10 hours single use (DD) and 7 days of extended wear (EW). Methods. Two similar study populations (DD, n = 55; EW, n = 53), were enrolled at four study sites. In each population, a bilateral, randomized, crossover (lens material), subject-masked experimental design was followed. Worn contact lenses were analyzed for lipid uptake using high-performance liquid chromatography by two laboratories: Alcon Laboratories (right lens total uptake) and OTG Research & Consultancy (left lens total uptake and individual lipid classes). Results. Lipid uptake was different for the two materials: total lipid (p < 0.007), cholesterol esters (p < 0.001), cholesterol (p<0.001 EW only), and triglycerides/phospholipids (p < 0.001) were higher for balafilcon A, whereas fatty acid (p<0.0025 EW only) was higher for etafilcon A. The ratio of the extracted lipids was also different: higher percentages of triglycerides/phospholipids (p < 0.001) and cholesterol (p < 0.001 EW only) for balafilcon A and higher percentages of fatty acids/di- and monoglycerides (p < 0.014) for etafilcon A. Conclusions. Total lipid uptake was highly material dependent. Both laboratories measured a greater uptake of lipids by the silicone hydrogel than the hydrogel material, a difference that was evident after only 10 hours of DD. Total lipid uptake was greater after 7 days of EW compared with 10 hours of DD. Of interest for contact lens spoliation and its avoidance was the differential lipid uptake profile, indicating material selectivity. Whereas greater differentiation between materials was possible after 7 days of EW for each material, the lipid uptake profile was similar for DD and EW, indicating a greater material effect than a wear modality effect.
引用
收藏
页码:1071 / 1083
页数:13
相关论文
共 50 条
  • [31] All soft contact lenses should be silicone hydrogel daily disposables
    Efron, Nathan
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2025, 108 (02) : 107 - 109
  • [32] Pseudomonas keratitis associated with daily wear of silicone hydrogel contact lenses
    Schornack, Muriel M.
    Faia, Lisa J.
    Griepentrog, Gregory J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (02): : 124 - 128
  • [33] Protein Deposition on a Lathe-Cut Silicone Hydrogel Contact Lens Material
    Subbaraman, Lakshman N.
    Woods, Jill
    Teichroeb, Jonathan H.
    Jones, Lyndon
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (03) : 244 - 250
  • [34] Clinical performance of different care systems with silicone hydrogel contact lenses
    Keir, Nancy
    Woods, Craig A.
    Dumbleton, Kathryn
    Jones, Lyndon
    CONTACT LENS & ANTERIOR EYE, 2010, 33 (04) : 189 - 195
  • [35] Solutions for Care of Silicone Hydrogel Lenses
    Willcox, Mark D. P.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 24 - 28
  • [36] Wettability and Silicone Hydrogel Lenses: A Review
    Keir, Nancy
    Jones, Lyndon
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 100 - 108
  • [37] Comfort and Vision with Silicone Hydrogel Lenses: Effect of Compliance
    Dumbleton, Kathryn
    Woods, Craig
    Jones, Lyndon
    Richter, Doris
    Fonn, Desmond
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (06) : 421 - 425
  • [38] Uptake and Release of Dexamethasone Phosphate From Silicone Hydrogel and Group I, II, and IV Hydrogel Contact Lenses
    Boone, Adrienne
    Hui, Alex
    Jones, Lyndon
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (05): : 260 - 267
  • [39] Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety
    Haworth, Kristina
    Travis, Darian
    Leslie, Louis
    Fuller, Daniel
    Pucker, Andrew D.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2023, (09):
  • [40] Novel silicone hydrogel based on PDMS and PEGMA for contact lens application
    Lin, Chien-Hong
    Yeh, Yi-Hsing
    Lin, Wen-Ching
    Yang, Ming-Chien
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 123 : 986 - 994