Contact Lens Lipid Spoliation of Hydrogel and Silicone Hydrogel Lenses

被引:15
作者
Maissa, Cecile [1 ,2 ]
Guillon, Michel [1 ]
Cockshott, Nik [1 ]
Garofalo, Renee J. [2 ]
Lemp, Jessie M. [2 ]
Boclair, Joseph W. [2 ]
机构
[1] OTG Res & Consultancy, London, England
[2] Alcon Labs Inc, Ft Worth, TX 76134 USA
关键词
lipid uptake; daily wear; extended wear; etafilcon A; balafilcon A; TEAR FILM LIPIDS; IN-VITRO; GROUP-II; DEPOSITION; QUANTIFICATION; PROTEIN; CHOLESTEROL;
D O I
10.1097/OPX.0000000000000341
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of the study was to measure contact lens lipid spoliation of silicone hydrogel PureVision (balafilcon A) and hydrogel Acuvue 2 (etafilcon A) contact lenses worn for 10 hours single use (DD) and 7 days of extended wear (EW). Methods. Two similar study populations (DD, n = 55; EW, n = 53), were enrolled at four study sites. In each population, a bilateral, randomized, crossover (lens material), subject-masked experimental design was followed. Worn contact lenses were analyzed for lipid uptake using high-performance liquid chromatography by two laboratories: Alcon Laboratories (right lens total uptake) and OTG Research & Consultancy (left lens total uptake and individual lipid classes). Results. Lipid uptake was different for the two materials: total lipid (p < 0.007), cholesterol esters (p < 0.001), cholesterol (p<0.001 EW only), and triglycerides/phospholipids (p < 0.001) were higher for balafilcon A, whereas fatty acid (p<0.0025 EW only) was higher for etafilcon A. The ratio of the extracted lipids was also different: higher percentages of triglycerides/phospholipids (p < 0.001) and cholesterol (p < 0.001 EW only) for balafilcon A and higher percentages of fatty acids/di- and monoglycerides (p < 0.014) for etafilcon A. Conclusions. Total lipid uptake was highly material dependent. Both laboratories measured a greater uptake of lipids by the silicone hydrogel than the hydrogel material, a difference that was evident after only 10 hours of DD. Total lipid uptake was greater after 7 days of EW compared with 10 hours of DD. Of interest for contact lens spoliation and its avoidance was the differential lipid uptake profile, indicating material selectivity. Whereas greater differentiation between materials was possible after 7 days of EW for each material, the lipid uptake profile was similar for DD and EW, indicating a greater material effect than a wear modality effect.
引用
收藏
页码:1071 / 1083
页数:13
相关论文
共 50 条
  • [21] Continuous wear silicone hydrogel contact lenses and microbial keratitis
    Whiting, MAN
    Raynor, MK
    Morgan, PB
    Galloway, P
    Tole, DM
    Tullo, A
    EYE, 2004, 18 (09) : 935 - 937
  • [22] Continuous wear silicone hydrogel contact lenses and microbial keratitis
    M A N Whiting
    M K Raynor
    P B Morgan
    P Galloway
    D M Tole
    A Tullo
    Eye, 2004, 18 : 935 - 937
  • [23] Novel in vitro method to determine pre-lens tear break-up time of hydrogel and silicone hydrogel contact lenses
    Walther, Hendrik
    Subbaraman, Lakshman N.
    Jones, Lyndon
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (02) : 178 - 184
  • [24] Impact of a Rinse Step on Protein Removal From Silicone Hydrogel Contact Lenses
    Pucker, Andrew D.
    Nichols, Jason J.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (08) : 943 - 947
  • [25] Biocompatibility in the Development of Silicone-Hydrogel Lenses
    Jacob, Jean T.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 13 - 19
  • [26] Microbial Adhesion to Silicone Hydrogel Lenses: A Review
    Willcox, Mark D. P.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 61 - 66
  • [27] Ex Vivo Analysis of Cholesterol Deposition for Commercially Available Silicone Hydrogel Contact Lenses Using a Fluorometric Enzymatic Assay
    Nash, Walter L.
    Gabriel, Manal M.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (05): : 277 - 282
  • [28] Quantification of individual proteins in silicone hydrogel contact lens deposits
    Omali, Negar Babaei
    Zhao, Zhenjun
    Zhu, Hua
    Tilia, Daniel
    Willcox, Mark D. P.
    MOLECULAR VISION, 2013, 19 : 390 - 399
  • [29] Pseudomonas keratitis associated with daily wear of silicone hydrogel contact lenses
    Schornack, Muriel M.
    Faia, Lisa J.
    Griepentrog, Gregory J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (02): : 124 - 128
  • [30] Lipid deposition on contact lenses in symptomatic and asymptomatic contact lens wearers
    Omali, Negar Babaei
    Subbaraman, Lakshman. N.
    Heynen, Miriam
    Lada, Mark
    Canavan, Kristy
    Fadli, Zohra
    Ngo, William
    Jones, Lyndon
    CONTACT LENS & ANTERIOR EYE, 2021, 44 (01) : 56 - 61