Decentration and tilt: Silicone multifocal versus acrylic soft intraocular lenses

被引:40
作者
Jung, CK [1 ]
Chung, SK [1 ]
Baek, NH [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Ophthalmol, Seoul, South Korea
关键词
D O I
10.1016/S0886-3350(99)00401-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare differences in decentration and tilt between a silicone multifocal and an acrylic intraocular lens (IOL) by evaluating postoperative changes. Setting: Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea. Methods: Forty eyes of 20 patients with IOL implantation were randomized into 2 groups according to IOL type: 3-piece silicone multifocal IOL or 3-piece acrylic IOL. All lenses were implanted in the capsular bag through a clear corneal incision after continuous curvilinear capsulorhexis and phacoemulsification. The amount of the decentration and the degree of the tilt of each IOL were measured using the EAS-1000 anterior eye segment analysis system 1 day and 1 and 2 months after surgery. Results: No significant difference in decentration and tilt was found among the 3 followups or between lens types. Conclusion: Neither IOL decentration nor tilt showed significant progression up to 2 months in eyes with a silicone multifocal or acrylic IOL when the IOLs were placed properly in the capsular bag. The amount of decentration and tilt was similar between lens types. J Cataract Refract Surg 2000; 26:582-585 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:582 / 585
页数:4
相关论文
共 14 条
[1]   AN EXPERIMENTAL-STUDY COMPARING VARIOUS ANTERIOR CAPSULECTOMY TECHNIQUES [J].
ASSIA, EI ;
APPLE, DJ ;
BARDEN, A ;
TSAI, JC ;
CASTANEDA, VE ;
HOGGATT, JS .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (05) :642-647
[2]   LONG-TERM DECENTRATION OF INTRAOCULAR LENSES IMPLANTED WITH ENVELOPE CAPSULOTOMY AND CONTINUOUS CURVILINEAR CAPSULOTOMY - A COMPARATIVE-STUDY [J].
CABALLERO, A ;
LOPEZ, MC ;
LOSADA, M ;
FLORES, DP ;
SALINAS, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (03) :287-292
[3]  
GUYTON DL, 1990, OPHTHALMOLOGY, V97, P1259
[4]   Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses [J].
Hayashi, K ;
Hayashi, H ;
Nakao, F ;
Hayashi, F .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (04) :419-422
[5]  
Hirokane Kenji, 1996, Nippon Ganka Gakkai Zasshi, V100, P240
[6]   PROSPECTIVE EXPERIMENTAL-STUDY OF FACTORS RELATED TO POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION [J].
LEGLER, UFC ;
ASSIA, EI ;
CASTANEDA, VE ;
HOGGATT, JP ;
APPLE, DJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05) :449-455
[7]   The role of capsulotomy and intraocular lens type on tilt and decentration of polymethylmethacrylate and foldable acrylic lenses [J].
Mutlu, FM ;
Bilge, AH ;
Altinsoy, HI ;
Yumusak, E .
OPHTHALMOLOGICA, 1998, 212 (06) :359-363
[8]   DECENTRATION ASSOCIATED WITH ASYMMETRIC CAPSULAR SHRINKAGE AND INTRAOCULAR-LENS SIZE [J].
OHMI, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (05) :640-643
[9]   MEASUREMENT OF INTRAOCULAR-LENS DECENTRATION AND TILT INVIVO [J].
PHILLIPS, P ;
PEREZEMMANUELLI, J ;
ROSSKOTHEN, HD ;
KOESTER, CJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (02) :129-135
[10]   MEASUREMENT OF POSTOPERATIVE INTRAOCULAR-LENS TILTING AND DECENTRATION USING SCHEIMPFLUG IMAGES [J].
SASAKI, K ;
SAKAMOTO, Y ;
SHIBATA, T ;
NAKAIZUMI, H ;
EMORI, Y .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (04) :454-457