MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T

被引:5
|
作者
Bian, Wei [1 ]
Kerr, Adam B. [2 ]
Tranvinh, Eric [3 ]
Parivash, Sherveen [3 ]
Zahneisen, Benjamin [3 ]
Han, May H. [4 ]
Lock, Christopher B. [4 ]
Goubran, Maged [3 ]
Zhu, Kongrong [2 ]
Rutt, Brian K. [3 ]
Zeineh, Michael M. [3 ]
机构
[1] Univ Elect Sci & Technol China, Sch Life Sci & Technol, Dept Biomed Engn, Chengdu, Sichuan, Peoples R China
[2] Stanford Univ, Dept Elect Engn, Palo Alto, CA 94304 USA
[3] Stanford Univ, Dept Radiol, Palo Alto, CA 94304 USA
[4] Stanford Univ, Sch Med, Dept Neurol & Neurol Sci, Palo Alto, CA 94304 USA
来源
PLOS ONE | 2019年 / 14卷 / 07期
基金
美国国家卫生研究院;
关键词
MULTIPLE-SCLEROSIS; HUMAN BRAIN; CORTICAL-LESIONS; TISSUE; T-1; CAIPIRINHA;
D O I
10.1371/journal.pone.0219705
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To develop a 7T simultaneous multi-slice (SMS) 2D gradient-echo sequence for susceptibility contrast imaging, and to compare its quality to 3D imaging. Methods A frequency modulated and phase cycled RF pulse was designed to simultaneously excite multiple slices in multi-echo 2D gradient-echo imaging. The imaging parameters were chosen to generate images with susceptibility contrast, including T-2*-weighted magnitude/phase images, susceptibility-weighted images and quantitative susceptibility/R-2* maps. To compare their image quality with 3D gradient-echo imaging, both 2D and 3D imaging were performed on 11 healthy volunteers and 4 patients with multiple sclerosis (MS). The signal to noise ratio (SNR) in gray and white matter and their contrast to noise ratio (CNR) was simulated for the 2D and 3D magnitude images using parameters from the imaging. The experimental SNRs and CNRs were measured in gray/white matter and deep gray matter structures on magnitude, phase, R-2* and QSM images from volunteers and the visibility of MS lesions on these images from patients was visually rated. All SNRs and CNRs were compared between the 2D and 3D imaging using a paired t-test. Results Although the 3D magnitude images still had significantly higher SNRs (by 13.0 similar to 17.6%), the 2D magnitude and QSM images generated significantly higher gray/white matter or globus pallidus/putamen contrast (by 13.3 similar to 87.5%) and significantly higher MS lesion contrast (by 5.9 similar to 17.3%). Conclusion 2D SMS gradient-echo imaging can serve as an alternative to often used 3D imaging to obtain susceptibility-contrast-weighted images, with an advantage of providing better image contrast and MS lesion sensitivity.
引用
收藏
页数:15
相关论文
共 27 条
  • [21] High-resolution gradient-recalled echo imaging at 9.4T using 16-channel parallel transmit simultaneous multislice spokes excitations with slice-by-slice flip angle homogenization
    Tse, Desmond H. Y.
    Wiggins, Christopher J.
    Poser, Benedikt A.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1050 - 1058
  • [22] Measurement of parenchymal extravascular R2* and tissue oxygen extraction fraction using multi-echo vascular space occupancy MRI at 7T
    Cheng, Ying
    van Zijl, Peter C. M.
    Hua, Jun
    NMR IN BIOMEDICINE, 2015, 28 (02) : 264 - 271
  • [23] Single-Shot T1 Mapping Using Simultaneous Acquisitions of Spin- and Stimulated-Echo-Planar Imaging (2D ss-SESTEPI)
    Shi, Xianfeng
    Kim, Seong-Eun
    Jeong, Eun-Kee
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 734 - 742
  • [24] Simultaneous multi-parametric mapping of total sodium concentration, T1, T2 and ADC at 7 T using a multi-contrast unbalanced SSFP
    Leroi, Lisa
    Coste, Arthur
    de Rochefort, Ludovic
    Santin, Mathieu D.
    Valabregue, Romain
    Mauconduit, Franck
    Giacomini, Eric
    Luong, Michel
    Chazel, Edouard
    Valette, Julien
    Le Bihan, Denis
    Poupon, Cyril
    Boumezbeur, Fawzi
    Rabrait-Lerman, Cecile
    Vignaud, Alexandre
    MAGNETIC RESONANCE IMAGING, 2018, 53 : 156 - 163
  • [25] Simultaneous multi-region detection of GABA plus and Glx using 3D spatially resolved SLOW-editing and EPSI-readout at 7T
    Weng, Guodong
    Slotboom, Johannes
    Schucht, Philippe
    Ermis, Ekin
    Wiest, Roland
    Kloppel, Stefan
    Peter, Jessica
    Zubak, Irena
    Radojewski, Piotr
    NEUROIMAGE, 2024, 286
  • [26] Multi-echo single-shot spectroscopy combined with simultaneous 2D model fitting for fast and accurate measurement of metabolite-specific concentrations and T2 relaxation times
    Rizzo, Rudy
    Kreis, Roland
    NMR IN BIOMEDICINE, 2023, 36 (12)
  • [27] Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI)
    Harris, Robert J.
    Yao, Jingwen
    Chakhoyan, Ararat
    Raymond, Catalina
    Leu, Kevin
    Liau, Linda M.
    Nghiemphu, Phioanh L.
    Lai, Albert
    Salamon, Noriko
    Pope, Whitney B.
    Cloughesy, Timothy F.
    Ellingson, Benjamin M.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1962 - 1978