MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T

被引:5
|
作者
Bian, Wei [1 ]
Kerr, Adam B. [2 ]
Tranvinh, Eric [3 ]
Parivash, Sherveen [3 ]
Zahneisen, Benjamin [3 ]
Han, May H. [4 ]
Lock, Christopher B. [4 ]
Goubran, Maged [3 ]
Zhu, Kongrong [2 ]
Rutt, Brian K. [3 ]
Zeineh, Michael M. [3 ]
机构
[1] Univ Elect Sci & Technol China, Sch Life Sci & Technol, Dept Biomed Engn, Chengdu, Sichuan, Peoples R China
[2] Stanford Univ, Dept Elect Engn, Palo Alto, CA 94304 USA
[3] Stanford Univ, Dept Radiol, Palo Alto, CA 94304 USA
[4] Stanford Univ, Sch Med, Dept Neurol & Neurol Sci, Palo Alto, CA 94304 USA
来源
PLOS ONE | 2019年 / 14卷 / 07期
基金
美国国家卫生研究院;
关键词
MULTIPLE-SCLEROSIS; HUMAN BRAIN; CORTICAL-LESIONS; TISSUE; T-1; CAIPIRINHA;
D O I
10.1371/journal.pone.0219705
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To develop a 7T simultaneous multi-slice (SMS) 2D gradient-echo sequence for susceptibility contrast imaging, and to compare its quality to 3D imaging. Methods A frequency modulated and phase cycled RF pulse was designed to simultaneously excite multiple slices in multi-echo 2D gradient-echo imaging. The imaging parameters were chosen to generate images with susceptibility contrast, including T-2*-weighted magnitude/phase images, susceptibility-weighted images and quantitative susceptibility/R-2* maps. To compare their image quality with 3D gradient-echo imaging, both 2D and 3D imaging were performed on 11 healthy volunteers and 4 patients with multiple sclerosis (MS). The signal to noise ratio (SNR) in gray and white matter and their contrast to noise ratio (CNR) was simulated for the 2D and 3D magnitude images using parameters from the imaging. The experimental SNRs and CNRs were measured in gray/white matter and deep gray matter structures on magnitude, phase, R-2* and QSM images from volunteers and the visibility of MS lesions on these images from patients was visually rated. All SNRs and CNRs were compared between the 2D and 3D imaging using a paired t-test. Results Although the 3D magnitude images still had significantly higher SNRs (by 13.0 similar to 17.6%), the 2D magnitude and QSM images generated significantly higher gray/white matter or globus pallidus/putamen contrast (by 13.3 similar to 87.5%) and significantly higher MS lesion contrast (by 5.9 similar to 17.3%). Conclusion 2D SMS gradient-echo imaging can serve as an alternative to often used 3D imaging to obtain susceptibility-contrast-weighted images, with an advantage of providing better image contrast and MS lesion sensitivity.
引用
收藏
页数:15
相关论文
共 27 条
  • [1] Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging
    Peng, Yuhong
    Zou, Chao
    Qiao, Yangzi
    Tie, Changjun
    Wan, Qian
    Jiang, Rui
    Cheng, Chuanli
    Liang, Dong
    Zheng, Hairong
    Li, Faqi
    Liu, Xin
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (06) : 771 - 779
  • [2] Concurrent CBF and BOLD FMRI with dual-echo spiral simultaneous multi-slice acquisitions at 7T
    Kurban, Denizhan
    Ivanov, Dimo
    Kashyap, Sriranga
    Huber, Laurentius
    Liberman, Gilad
    Poser, Benedikt A.
    NEUROIMAGE, 2022, 247
  • [3] Slice Accelerated Gradient-Echo Spin-Echo Dynamic Susceptibility Contrast Imaging with Blipped CAIPI for Increased Slice Coverage
    Eichner, Cornelius
    Jafari-Khouzani, Kourosh
    Cauley, Stephen
    Bhat, Himanshu
    Polaskova, Pavlina
    Andronesi, Ovidiu C.
    Rapalino, Otto
    Turner, Robert
    Wald, Lawrence L.
    Stufflebeam, Steven
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 770 - 778
  • [4] Improving diffusion MRI using simultaneous multi-slice echo planar imaging
    Setsompop, K.
    Cohen-Adad, J.
    Gagoski, B. A.
    Raij, T.
    Yendiki, A.
    Keil, B.
    Wedeen, V. J.
    Wald, L. L.
    NEUROIMAGE, 2012, 63 (01) : 569 - 580
  • [5] Using multi-echo simultaneous multi-slice (SMS) EPI to improve functional MRI of the subcortical nuclei of the basal ganglia at ultra-high field (7T)
    Puckett, Alexander M.
    Bollmann, Saskia
    Poser, Benedikt A.
    Palmer, Jake
    Barth, Markus
    Cunnington, Ross
    NEUROIMAGE, 2018, 172 : 886 - 895
  • [6] Imaging arterial and venous vessels using Iron Dextran enhanced multi-echo 3D gradient echo MRI at 7T
    Li, Yinghao
    Li, Wei
    Paez, Adrian
    Cao, Di
    Sun, Yuanqi
    Gu, Chunming
    Zhang, Kaihua
    Miao, Xinyuan
    Liu, Peiying
    Li, Wenbo
    Pillai, Jay
    Lu, Hanzhang
    van Zijl, Peter C. M.
    Earley, Christopher
    Li, Xu
    Hua, Jun
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [7] Adaptive slice-specific z-shimming for 2D spoiled gradient-echo sequences
    Soellradl, Martin
    Strasser, Johannes
    Lesch, Andreas
    Stollberger, Rudolf
    Ropele, Stefan
    Langkammer, Christian
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (02) : 818 - 830
  • [8] Gradient-Echo EPI Using a High-Degree Shim Insert Coil at 7T: Implications for BOLD fMRI
    Kim, Tae
    Lee, Yoojin
    Zhao, Tiejun
    Hetherington, Hoby P.
    Pan, Jullie W.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1734 - 1745
  • [9] Cervical spinal cord multiple sclerosis: evaluation with 2D multi-echo recombined gradient echo MR imaging
    White, Matthew L.
    Zhang, Yan
    Healey, Kathleen
    JOURNAL OF SPINAL CORD MEDICINE, 2011, 34 (01) : 93 - 98
  • [10] Blipped multi gradient-echo slice excitation profile imaging (bmGESEPI) for fast T*2 measurements with macroscopic B0 inhomogeneity compensation
    Truong, Trong-Kha
    Chakeres, Donald W.
    Scharre, Douglas W.
    Beversdorf, David Q.
    Schmalbrock, Petra
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1390 - 1395