VOLUMETRIC INTENSITY-MODULATED ARC THERAPY VS. CONVENTIONAL IMRT IN HEAD-AND-NECK CANCER: A COMPARATIVE PLANNING AND DOSIMETRIC STUDY

被引:362
作者
Verbakel, Wilko F. A. R. [1 ]
Cuijpers, Johan P. [1 ]
Hoffmans, Daan [1 ]
Bieker, Michael [1 ]
Slotman, Ben J. [1 ]
Senan, Suresh [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Radiat Oncol, NL-1081 HV Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 74卷 / 01期
关键词
Arc therapy; RapidArc; Film dosimetry; Planning study; Head-and-neck cancer; PHOTON DOSE CALCULATION; RADIATION-THERAPY; RADIOTHERAPY; DELIVERY; BEAM; IMPLEMENTATION; DELINEATION; XEROSTOMIA; ALGORITHM; WATER;
D O I
10.1016/j.ijrobp.2008.12.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Volumetric intensity-modulated arc therapy (RA) allows for rapid delivery of highly conformal dose distributions. In this study, planning and dosimetry of RA were compared with conventional intensity-modulated radiation therapy (IMRT) plans of head-and-neck cancer patients. Materials and Methods: Computed tomography scans of 12 patients who had completed IMRT for advanced tumors of the naso-, oro-and hypopharynx were replanned using RA using either one or two arcs. Calculated doses to planning target volume (PTV) and organs at risk (OAR) were compared between IMRT and RA plans. Dose distributions for single are (n = 8) and double arc (n = 4) plans were verified using film dosimetry in three to five coronal planes using a quality assurance phantom. Results: RA plans allowed for a mean reduction in number of monitor units (MU) by nearly 60%, relative to seven field sliding window IMRT plans. RA plans achieved similar sparing of all OAR as IMRT. Double arc RA provided the best dose homogeneity to PTV with a lower standard deviation of PTV dose (1.4 Gy), vs. single arc plans (2.0 Gy) and IMRT (1.7 Gy). Film measurements showed good correspondence with calculated doses; the mean gamma value was 0.30 (double arc) and area of the film with a gamma exceeding 1 was 0.82%. Conclusions: RA is a fast, safe, and accurate technique that uses lower MUs than conventional IMRT. Double arc plans provided at least similar sparing of OAR and better PTV dose homogeneity than single are or IMRT. (C) 2009 Elsevier Inc.
引用
收藏
页码:252 / 259
页数:8
相关论文
共 24 条
[1]   Intensity-modulated radiotherapy significantly reduces xerostomia compared with conventional radiotherapy [J].
Braam, Petra M. ;
Terhaard, Chris H. J. ;
Roesink, Judith M. ;
Raaijmakers, Cornelis P. J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04) :975-980
[2]   Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation [J].
Cameron, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (18) :4317-4336
[3]   Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods [J].
Chui, CS ;
Chan, MF ;
Yorke, E ;
Spirou, S ;
Ling, CC .
MEDICAL PHYSICS, 2001, 28 (12) :2441-2449
[4]   Intensity-modulated radiation therapy dose prescription, recording, and delivery: Patterns of variability among institutions and treatment planning systems [J].
Das, Indra J. ;
Cheng, Chee-Wai ;
Chopra, Kashmiri L. ;
Mitra, Raj K. ;
Srivastava, Shiv P. ;
Glatstein, Eli .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2008, 100 (05) :300-307
[5]  
DIJKEMA T, INT J RAD O IN PRESS
[6]   Inverse planning for intensity-modulated arc therapy using direct aperture optimization [J].
Earl, MA ;
Shepard, DM ;
Naqvi, S ;
Li, XA ;
Yu, CX .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) :1075-1089
[7]   Salivary gland sparing and improved target irradiation by conformal and intensity modulated irradiation of head and neck cancer [J].
Eisbruch, A ;
Ship, JA ;
Dawson, LA ;
Kim, HM ;
Bradford, CR ;
Terrell, JE ;
Chepeha, DB ;
Teknos, TN ;
Hogikyan, ND ;
Anzai, Y ;
Marsh, LH ;
Ten Haken, RK ;
Wolf, GT .
WORLD JOURNAL OF SURGERY, 2003, 27 (07) :832-837
[8]   Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation [J].
Essers, M ;
de Langen, M ;
Dirkx, MLP ;
Heijmen, BJM .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) :215-224
[9]   Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water [J].
Fogliata, A ;
Nicolini, G ;
Vanetti, E ;
Clivio, A ;
Cozzi, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) :1421-1438
[10]   Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine [J].
Galvin, JM ;
Ezzell, G ;
Eisbrauch, A ;
Yu, C ;
Butler, B ;
Xiao, Y ;
Rosen, I ;
Rosenman, J ;
Sharpe, M ;
Xing, L ;
Xia, P ;
Lomax, T ;
Low, DA ;
Palta, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05) :1616-1634