Understanding the impact of pelvic organ motion on dose delivered to target volumes during IMRT for cervical cancer

被引:25
作者
Eminowicz, Gemma [1 ]
Rompokos, Vasilis [1 ]
Stacey, Christopher [1 ]
Hall, Lisa [1 ]
McCormack, Mary [1 ]
机构
[1] Univ Coll London Hosp, Dept Radiotherapy, 250 Euston Rd, London NW1 2PG, England
关键词
Cervical cancer radiotherapy; Organ motion; Dosimetry; DEFORMABLE IMAGE REGISTRATION; MODULATED RADIATION-THERAPY; RADIOTHERAPY; MALIGNANCIES; UTERINE; CT;
D O I
10.1016/j.radonc.2016.10.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Advanced radiotherapy techniques reduce normal tissue dose by conforming closely to target volumes. In cervical cancer radiotherapy, organ filling affects clinical target volume (CTV; cervix, uterus) position. This study estimates the dosimetric effect of this primary CTV position variation during chemoradiation. Methods/materials: Twice weekly cone-beam computed tomography (CBCT) images of ten patients undergoing cervical chemoradiation were retrospectively analysed. Primary CTV, bladder and rectum were delineated. RapidArc plans were created using 10-15 mm CTV-PTV margins and dose delivered to CTV based on each CBCT position was calculated using a novel vector approach. Dose delivered along the central uterine, mid-uterus and cervix vectors were analysed as well as dose delivered to points at uterine tip, anterior mid-uterus and anterior cervix. Additional RapidArc plans were created for large planning bladder volume cases using the CTV acquired with bladder volume at 150-300 cc. Results: 105 scans for 10 patients were analysed. Vector analysis revealed CTV underdosing in certain cases. Below 95% average vector coverage was found for all three vectors in 2 cases and one vector in 1 case. Volumetric analysis revealed D99 < 95% in 48% of fractions. Patients with large planning bladder volumes (>300 cc) demonstrated the largest variation. Replanning improved this coverage. The anterior mid-uterus point was least well-covered; median 98.7% dose, reducing to 91.4% in cases with large planning bladder volumes. Again, replanning significantly improved this. D99 > 95% was maintained in 93% of fractions when bladder volume was 50 cc below to 150 cc above planning volume compared to 24% of fractions if bladder volume was outside this range. Similarly, D95 > 95% was 100% versus 84%. Conclusion: Organ position variation detrimentally affected dose delivered to CTV including cervix. Large planning bladder volumes (>300 cc) led to more variation. We recommend bladder volumes of 150-300 cc at planning and a range of 50 cc below to 150 cc above planning for treatment. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 19 条
[1]   Increasing treatment accuracy for cervical cancer patients using correlations between bladder-filling change and cervix-uterus displacements: Proof of principle [J].
Ahmad, Rozilawati ;
Hoogeman, Mischa S. ;
Bondar, Maria ;
Dhawtal, V. ;
Quint, Sandra ;
De Pree, Ilse ;
Mens, Jan Willem ;
Heijmen, Ben J. M. .
RADIOTHERAPY AND ONCOLOGY, 2011, 98 (03) :340-346
[2]   Inter-fraction bladder filling variations and time trends for cervical cancer patients assessed with a portable 3-dimensional ultrasound bladder scanner [J].
Ahmad, Rozilawati ;
Hoogeman, Mischa S. ;
Quint, Sandra ;
Mens, Jan Willem ;
de Pree, Ilse ;
Heijmen, Ben J. M. .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :172-179
[3]   CERVIX REGRESSION AND MOTION DURING THE COURSE OF EXTERNAL BEAM CHEMORADIATION FOR CERVICAL CANCER [J].
Beadle, Beth M. ;
Jhingran, Anuja ;
Salehpour, Mohammad ;
Sam, Marianne ;
Iyer, Revathy B. ;
Eifel, Patricia I. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01) :235-241
[4]   Inter- and intrafractional tumor and organ movement in patients with cervical cancer undergoing radiotherapy: A cinematic-MRI point-of-interest study [J].
Chan, Philip ;
Dinniwell, Robert ;
Haider, Masoom A. ;
Cho, Young-Bin ;
Jaffray, David ;
Lockwood, Gina ;
Levin, Wilfred ;
Manchul, Lee ;
Fyles, Anthony ;
Milosevic, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (05) :1507-1515
[5]  
Eminowicz G, 2016, CLIN ONCOL
[6]   Factors influencing bowel sparing in intensity modulated whole pelvic radiotherapy for gynaecological malignancies [J].
Georg, Petra ;
Georg, Dietmar ;
Hillbrand, Martin ;
Kirisits, Christian ;
Poetter, Richard .
RADIOTHERAPY AND ONCOLOGY, 2006, 80 (01) :19-26
[7]   The effect of uterine motion and uterine margins on target and normal tissue doses in intensity modulated radiation therapy of cervical cancer [J].
Gordon, J. J. ;
Weiss, E. ;
Abayomi, O. K. ;
Siebers, J. V. ;
Dogan, N. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (10) :2887-2901
[8]   Interfractional dose variation during intensity-modulated radiation therapy for cervical cancer assessed by weekly CT evaluation [J].
Han, Youngyih ;
Shin, Eun Hyuk ;
Huh, Seung Jae ;
Lee, Jung Eun ;
Park, Won .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :617-623
[9]   Clinical Implementation of an Online Adaptive Plan-of-the-Day Protocol for Nonrigid Motion Management in Locally Advanced Cervical Cancer IMRT [J].
Heijkoop, Sabrina T. ;
Langerak, Thomas R. ;
Quint, Sandra ;
Bondar, Luiza ;
Mens, Jan Willem M. ;
Heijmen, Ben J. M. ;
Hoogeman, Mischa S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (03) :673-679
[10]   A Systematic Review of Organ Motion and Image-guided Strategies in External Beam Radiotherapy for Cervical Cancer [J].
Jadon, R. ;
Pembroke, C. A. ;
Hanna, C. L. ;
Palaniappan, N. ;
Evans, M. ;
Cleves, A. E. ;
Staffurth, J. .
CLINICAL ONCOLOGY, 2014, 26 (04) :185-196