In-vitro experimental analysis and numerical study of temperature in bone drilling

被引:12
作者
Alam, Khurshid [1 ]
Khan, Mushtaq [2 ]
Muhammad, Riaz [3 ]
Qamar, Sayyad Zahid [1 ]
Silberschmidt, Vadim V. [4 ]
机构
[1] Sultan Qaboos Univ, Coll Engn, Dept Mech & Ind Engn, Muscat, Oman
[2] Natl Univ Sci & Technol, Sch Mech & Mfg Engn, Islamabad, Pakistan
[3] CECOS Univ IT & Emerging Sci, Dept Mech Engn, Hayat Abad, Pakistan
[4] Univ Loughborough, Wolfson Sch Mech & Mfg Engn, Loughborough, Leics, England
关键词
Orthopaedic; bone drilling; experimental analysis; FE modelling; thermal necrosis; CORTICAL BONE; CRACKING; FORCE; RISE;
D O I
10.3233/THC-151035
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Bone drilling is a common practice of surgical treatments in orthopaedics and traumatology. Penetration of a high-speed drill into bone tissue is accompanied by generation of a significant amount of heat. Cooling of the drilling region is necessary to avoid potential risk of thermal damage to bone. OBJECTIVE: The purpose of this study was to measure and predict bone temperature by conducting experiments and numerical simulations using cooling by means of irrigation at two different temperatures. METHODS: A series of experiments and numerical studies were performed to investigate the effect of cooling conditions on the rise in bone temperature in drilling. The temperature increase in bone was assessed for different drilling speeds and feed rates in the presence irrigation at 5 degrees C and 25 degrees C. RESULTS: Bone temperature was found to be strongly affected by the drilling parameters and cooling conditions. Irrigation with water at 5 degrees C kept bone temperature well below the thermal threshold level. CONCLUSION: This study strongly recommends the use of irrigation at lower temperature for safe surgical incision.
引用
收藏
页码:775 / 783
页数:9
相关论文
共 28 条
[1]  
Abouzgia MB, 1997, INT J ORAL MAX IMPL, V12, P342
[2]  
Alam K, 2015, SCI IRAN, V22, P487
[3]   Experimental and numerical investigation of cracking behavior of cortical bone in cutting [J].
Alam, K. .
TECHNOLOGY AND HEALTH CARE, 2014, 22 (05) :741-750
[4]   Analysis of temperature in conventional and ultrasonically-assisted drilling of cortical bone with infrared thermography [J].
Alam, K. ;
Silberschmidt, Vadim V. .
TECHNOLOGY AND HEALTH CARE, 2014, 22 (02) :243-252
[5]   Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone [J].
Alam, K. ;
Mitrofanov, A. V. ;
Silberschmidt, V. V. .
MEDICAL ENGINEERING & PHYSICS, 2011, 33 (02) :234-239
[6]   Stresses in ultrasonically assisted bone cutting [J].
Alam, K. ;
Mitrofanov, A. V. ;
Baeker, M. ;
Silberschmidt, V. V. .
7TH INTERNATIONAL CONFERENCE ON MODERN PRACTICE IN STRESS AND VIBRATION ANALYSIS, 2009, 181
[7]   3D Finite-Element Modelling of Drilling Cortical Bone: Temperature Analysis [J].
Alam, Khurshid ;
Khan, Mushtaq ;
Silberschmidt, Vadim V. .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (06) :618-623
[8]   Analysis of forces in conventional and ultrasonically assisted plane cutting of cortical bone [J].
Alam, Khurshid ;
Khan, Mushtaq ;
Silberschmidt, Vadim V. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H6) :636-642
[9]   On-line analysis of cracking in cortical bone under wedge penetration [J].
Alam, Khurshid ;
Kerckhofs, Greet ;
Mitrofanov, Alexander V. ;
Lomov, Stepan ;
Wevers, Martin ;
Silberschmidt, Vadim V. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H9) :709-717
[10]  
[Anonymous], 2009, THESIS LOUGHBOROUGH