Validity of using tri-axial accelerometers to measure human movement - Part II: Step counts at a wide range of gait velocities

被引:103
作者
Fortune, Emma [1 ]
Lugade, Vipul [1 ]
Morrow, Melissa [1 ]
Kaufman, Kenton [1 ]
机构
[1] Mayo Clin, Mot Anal Lab, Div Orthoped Res, Rochester, MN 55905 USA
关键词
Accelerometer; Step detection; Body-worn sensors; Gait velocity; PHYSICAL-ACTIVITIES; PARKINSONS-DISEASE; ACTIVITY MONITOR; ACCURACY; PEDOMETER; SPEED; COMMUNITY; WALKING; CLASSIFICATION; RELIABILITY;
D O I
10.1016/j.medengphy.2014.02.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A subject-specific step counting method with a high accuracy level at all walking speeds is needed to assess the functional level of impaired patients. The study aim was to validate step counts and cadence calculations from acceleration data by comparison to video data during dynamic activity. Custom-built activity monitors, each containing one tri-axial accelerometer, were placed on the ankles, thigh, and waist of 11 healthy adults. ICC values were greater than 0.98 for video inter-rater reliability of all step counts. The activity monitoring system (AMS) algorithm demonstrated a median (interquartile range; IQR) agreement of 92% (8%) with visual observations during walking/jogging trials at gait velocities ranging from 0.1 to 4.8 m/s, while FitBits (ankle and waist), and a Nike Fuelband (wrist) demonstrated agreements of 92% (36%), 93% (22%), and 33% (35%), respectively. The algorithm results demonstrated high median (IQR) step detection sensitivity (95% (2%)), positive predictive value (PPV) (99% (1%)), and agreement (97% (3%)) during a laboratory-based simulated free-living protocol. The algorithm also showed high median (IQR) sensitivity, PPV, and agreement identifying walking steps (91% (5%), 98% (4%), and 96% (5%)), jogging steps (97% (6%), 100% (1%), and 95% (6%)), and less than 3% mean error in cadence calculations. (C) 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:659 / 669
页数:11
相关论文
共 45 条
  • [1] Five-year change in physical activity is associated with changes in cardiovascular disease risk factors The Inter99 study
    Aadahl, M.
    Smith, L. von Huth
    Pisinger, C.
    Toft, U. N.
    Glumer, C.
    Borch-Johnsen, K.
    Jorgensen, T.
    [J]. PREVENTIVE MEDICINE, 2009, 48 (04) : 326 - 331
  • [2] Compendium of Physical Activities: an update of activity codes and MET intensities
    Ainsworth, BE
    Haskell, WL
    Whitt, MC
    Irwin, ML
    Swartz, AM
    Strath, SJ
    O'Brien, WL
    Bassett, DR
    Schmitz, KH
    Emplaincourt, PO
    Jacobs, DR
    Leon, AS
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S498 - S516
  • [3] Classification of a known sequence of motions and postures from accelerometry data using adapted Gaussian mixture models
    Allen, Felicity R.
    Ambikairajah, Eliathamby
    Lovell, Nigel H.
    Celler, Branko G.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2006, 27 (10) : 935 - 951
  • [4] Alwan A, 2011, GLOBAL STATUS REPORT ON NONCOMMUNICABLE DISEASES 2010, pVII
  • [5] Sensor Positioning for Activity Recognition Using Wearable Accelerometers
    Atallah, Louis
    Lo, Benny
    King, Rachel
    Yang, Guang-Zhong
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2011, 5 (04) : 320 - 329
  • [6] Energy cost of stair climbing and descending on the college alumnus questionnaire
    Bassett, DR
    Vachon, JA
    Kirkland, AO
    Howley, ET
    Duncan, GE
    Johnson, KR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (09) : 1250 - 1254
  • [7] Temporal parameters and patterns of the foot roll over during walking: normative data for healthy adults
    Blanc, Y
    Balmer, C
    Landis, T
    Vingerhoets, F
    [J]. GAIT & POSTURE, 1999, 10 (02) : 97 - 108
  • [8] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [9] Quantification of physical activities by means of ambulatory accelerometry: A validation study
    Bussmann, JBJ
    Tulen, JHM
    van Herel, ECG
    Stam, HJ
    [J]. PSYCHOPHYSIOLOGY, 1998, 35 (05) : 488 - 496
  • [10] Validity of 10 electronic pedometers for measuring steps, distance, and energy cost
    Crouter, SE
    Schneider, PL
    Karabulut, M
    Bassett, DR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) : 1455 - 1460