Clinical and angiographic results after mechanical connection for distal anastomosis in coronary surgery

被引:18
作者
Carrel, T [1 ]
Englberger, L
Keller, D
Windecker, S
Meier, B
Eckstein, F
机构
[1] Univ Hosp Bern, Cardiovasc Surg Clin, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Div Cardiol, CH-3010 Bern, Switzerland
关键词
D O I
10.1016/j.jtcvs.2003.11.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sutureless anastomotic devices are of increasing interest in cardiovascular surgery. We investigated the stainless steel clip system of St Jude Medical/Anastomotic Technology Group (Maple Grove, Minn) to connect saphenous vein grafts with coronary arteries. Methods: Forty-five patients were enrolled in this feasibility study performed on patients who had on-pump coronary artery bypass grafting, but 32 patients only received I distal anastomosis with this investigational device (2.5 mm [n = 14] and 2.0 mm [n = 18]). Thirteen were excluded because target vessels were too small, calcified, or tortuous. The system consists of an expandable clip mounted on a balloon catheter; delivery is obtained during balloon inflation. The main differences between the 2.5-mm and 2.0-mm devices are different loading and deployment in smaller coronary arteries for the 2.0-mm device. Results: A connecting device was deployed on the right coronary artery in 14 patients, the posterior descending branch in 12 patients, the obtuse marginal in 5 patients, and the posterolateral branch in I patient. Perfect hemostasis of the sutureless connector anastomosis was obtained in 28 patients. Three connectors were removed because of minor leakage at the connection site, and I connector was removed because of mismanipulation after successful deployment. Hand-sewn anastomosis was performed at the same arteriotomy site. Intraoperative flow was assessed by the transit time method and averaged 71 +/- 24 mL/min. One patient died of neurologic injury; the connector was patent at autopsy. One patient had a perioperative myocardial infarction. There was no adverse cardiac event in the remaining patients. All patients underwent clinical follow-up after 6 and 12 months and 35 angiograms were available in 21 patients: after 3 and 6 months, 17 anastomoses were patent and the saphenous vein graft was occluded in 4 patients. Conclusions: The coronary connector system from St Jude Medical/Anastomotic Technology Group allows consistently uniform sutureless connection between the saphenous vein graft and coronary artery. Loading and deployment require careful training. This technology is under constant development and may give a significant boost to less invasive coronary revascularization techniques.
引用
收藏
页码:1632 / 1640
页数:9
相关论文
共 27 条
[1]   Safety and efficacy of off-pump coronary artery bypass grafting [J].
Arom, KV ;
Flavin, TF ;
Emery, RW ;
Kshettry, VR ;
Janey, PA ;
Petersen, RJ .
ANNALS OF THORACIC SURGERY, 2000, 69 (03) :704-710
[2]   Influence of suture technique and suture material selection on the mechanics of end-to-end and end-to-side anastomoses [J].
Baumgartner, N ;
Dobrin, PB ;
Morasch, M ;
Dong, QS ;
Mrkvicka, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05) :1063-1072
[3]   Facilitated vascular interrupted anastomosis in cardiovascular surgery with a new clip device [J].
Berdat, PA ;
Kipfer, B ;
Immer, FF ;
Pfammatter, JP ;
Carrel, T .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (06) :1256-1258
[4]  
BORST C, 2002, SYMMETRY M 2002 EVOL
[5]   Closed-chest coronary artery bypass grafting on the beating heart with the use of a computer-enhanced surgical robotic system [J].
Boyd, WD ;
Rayman, R ;
Desai, ND ;
Menkis, AH ;
Dobkowski, W ;
Ganapathy, S ;
Kiaii, B ;
Jablonsky, G ;
McKenzie, FN ;
Novick, RJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (04) :807-809
[6]   Sutureless coronary anastomosis with an anastomotic device and tissue adhesive in off-pump porcine coronary bypass grafting [J].
Buijsrogge, MP ;
Scheltes, JS ;
Heikens, M ;
Gründeman, PF ;
Pistecky, PV ;
Borst, C .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :788-794
[7]   Clinical experience with devices for facilitated anastomoses in coronary artery bypass surgery [J].
Carrel, TP ;
Eckstein, FS ;
Englberger, L ;
Berdat, PA ;
Schmidli, J .
ANNALS OF THORACIC SURGERY, 2004, 77 (03) :1110-1120
[8]   The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting [J].
Eckstein, FS ;
Bonilla, LF ;
Englberger, L ;
Immer, FF ;
Berg, TA ;
Schmidli, J ;
Carrel, TP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :777-782
[9]   First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG [J].
Eckstein, FS ;
Bonilla, LF ;
Englberger, L ;
Eberli, F ;
Windecker, S ;
Berg, TA ;
Romanens, M ;
Immer, FF ;
Carrel, TP .
CIRCULATION, 2002, 106 (13) :I1-I4
[10]   Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses [J].
Eckstein, FS ;
Bonilla, LF ;
Englberger, L ;
Stauffer, E ;
Berg, TA ;
Schmidli, J ;
Carrel, TP .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :S995-S998