Comparative investigation of two rotary nickel-titanium instruments:: ProTaper versus RaCe.: Part 1.: Shaping ability in simulated curved canals

被引:86
作者
Schäfer, E [1 ]
Vlassis, M [1 ]
机构
[1] Univ Munster, Dept Operat Dent, D-48149 Munster, Germany
关键词
canal transportation; curved root canals; nickel-titanium; resin blocks; root canal preparation; rotary instruments;
D O I
10.1111/j.0143-2885.2004.00786.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the shaping ability of ProTaper with Reamer with Alternating Cutting Edges (RaCe) instruments. Part 1 of this two-part report describes the efficacy of these two nickel-titanium instruments in simulated curved root canals. Methodology Simulated canals with 28degrees and 35degrees curves in resin blocks were prepared with ProTaper and RaCe instruments using a crown-down preparation technique (n = 24 canals in each case). Pre- and postinstrumentation images were recorded, and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 20 measuring points, beginning 1 mm from the apex. Incidence of canal aberrations, preparation time, changes of working length and instrument failures were also recorded. The data were analysed statistically using the Mann-Whitney U-test or the chi-square test. Results: On average, canals prepared with RaCe instruments remained better centred compared with those enlarged with ProTaper files. Three RaCe instruments and two ProTaper files fractured during preparation (P > 0.05). Between both the canal types, RaCe was significantly faster (P < 0.001) than ProTaper and maintained working length significantly better (P < 0.05). Conclusion Both instruments prepared curved canals rapidly and were relatively safe. RaCe respected original canal curvature better than ProTaper, which tended to transport towards the outer aspect of the curve.
引用
收藏
页码:229 / 238
页数:10
相关论文
共 26 条
  • [1] COMPARISON OF 6 FILES TO PREPARE SIMULATED ROOT CANALS .2.
    ALOMARI, MAO
    DUMMER, PMH
    NEWCOMBE, RG
    DOLLER, R
    HARTLES, F
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1992, 25 (02) : 67 - 81
  • [2] [Anonymous], 1994, Int Endod J, V27, P115
  • [3] Effect of experience on quality of canal preparation with rotary nickel-titanium files
    Baumann, MA
    Roth, A
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (06): : 714 - 718
  • [4] Baumann MA, 2003, J ENDODONT, V29, P286
  • [5] Progressive versus constant tapered shaft design using NiTi rotary instruments
    Bergmans, L
    Van Cleynenbreugel, J
    Beullens, M
    Wevers, M
    Van Meerbeek, B
    Lambrechts, P
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (04) : 288 - 295
  • [6] Bergmans L, 2001, AM J DENT, V14, P324
  • [7] THE INFLUENCE OF DIFFERENT ROOT-CANAL INSTRUMENTS ON ROOT-CANAL PREPARATION - AN INVITRO STUDY
    BRISENO, BM
    SONNABEND, E
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1991, 24 (01) : 15 - 23
  • [8] COSBY VD, 2003, J ENDODONT, V29, P288
  • [9] ELASAAD MG, 2002, J ENDODONT, V28, P247
  • [10] A comparative study of root canal preparation using FlexMaster and HERO 642 rotary Ni-Ti instruments
    Hülsmann, M
    Gressmann, G
    Schäfers, F
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (05) : 358 - 366