Prostate cancer: contouring target and organs at risk by kilovoltage and megavoltage CT and MRI in patients with and without hip prostheses

被引:4
|
作者
Falcinelli, Lorenzo [1 ]
Palumbo, Isabella [2 ,3 ]
Radicchia, Valentina [2 ,3 ]
Arcidiacono, Fabio [2 ,3 ]
Lancellotta, Valentina [2 ,3 ]
Montesi, Giampaolo [2 ,3 ]
Matrone, Fabio [2 ,3 ]
Zucchetti, Claudio [4 ]
Marcantonini, Marta [4 ]
Bini, Vittorio [5 ]
Aristei, Cynthia [2 ,3 ]
机构
[1] Perugia Gen Hosp, Div Radiat Oncol, Dept Oncohaematol & Gastroenterol Sci, Perugia, Italy
[2] Univ Perugia, Dept Surg & Biomed Sci, Radiat Oncol Sect, I-06100 Perugia, Italy
[3] Perugia Gen Hosp, Perugia, Italy
[4] Perugia Gen Hosp, Med Phys Unit, Dept Imaging & Lab Diag, Perugia, Italy
[5] Perugia Gen Hosp, Internal Med Endocrine & Metab Sci Sect, Perugia, Italy
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1056期
关键词
RADIOTHERAPY; REDUCTION;
D O I
10.1259/bjr.20150509
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: In radiotherapy treatment, planning target volume and organs at risk are contoured on kilovoltage CT (kVCT) images. Unlike MR images, kVCT does not provide precise information on target volume extension. Since neither kVCT nor MRI may be suitable for contouring in patients with ferrous hip prostheses, this study evaluated whether megavoltage CT (MVCT) reduced interobserver variability. Methods: Two patients without hip prostheses and one patient (Patient 3) with hip prostheses were enrolled. Six radiation oncologists contoured prostate, rectum and bladder on kVCT (Patients 1 and 3), MRI (Patient 2) and MVCT images (Patient 3). MVCT was acquired with fine, normal and coarse modalities. Interobserver variability for each organ was analysed using conformity index (CI) and coefficient of variation (CV). Results: In patients without hip prostheses, CIs were higher in prostate contouring with MRI than with kVCT, indicating lower interobserver variability with MRI. Very slight variations were seen in rectum and bladder contouring. In the patient with hip prostheses (Patient 3), contouring on kVCT lowered CI and increased CV in the prostate, bladder and rectum. The differences were more marked in the prostate. Only fine modality MVCT reduced interobserver variability and only for the prostate. Conclusion: Even though greater noise and less soft-tissue contrast increase contouring variability with MVCT than with kVCT, lack of artefacts on MVCT could provide better image definition by this modality in hip prosthesis patients in whom MRI is precluded. Advances in knowledge: We recommend the fine modality MVCT for contouring hip prostheses patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Prostate Contouring in Patients with Bilateral Hip Prostheses: Impact of Using Artifact-Reduced CT Images and MRI
    Elzibak, A.
    Loblaw, A.
    Morton, G.
    Vesprini, D.
    Liu, S.
    Chung, H.
    Davidson, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3444 - 3445
  • [2] Prostate delineation using CT and MRI for radiotherapy patients with bilateral hip prostheses
    Rosewall, Tara
    Kong, Vickie
    Vesprini, Danny
    Catton, Charles
    Chung, Peter
    Menard, Cynthia
    Bayley, Andrew
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) : 325 - 330
  • [3] Contouring variability with CT and MRI of prostate cancer for radiation planning
    Otero-Romero, A.
    Perez-Rozos, A.
    Correa-Generoso, R.
    Jerez-Sainz, I.
    Garcia-Anaya, M. J.
    Zapata-Martinez, I.
    Roman-Jobacho, A.
    Toledo-Serrano, M. D.
    Ordonez-Marmolejo, R.
    Garcia-Rios, I.
    Gomez-Millan, J.
    Villalobos-Martin, J. A.
    Diaz-Antonio, T.
    Medina-Carmona, J. A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S714 - S714
  • [4] INTEROBSERVER VARIATION IN MRI AND CT BASED CONTOURING FOR PROSTATE CANCER
    Segedin, B.
    Hadzic, J. But
    Rogelj, P.
    Sesek, M.
    Logar, H. B. Zobec
    Kragelj, B.
    Petric, P.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S285 - S285
  • [5] Target volume coverage and dose to organs at risk in prostate cancer patients
    Huettenrauch, P.
    Witt, M.
    Wolff, D.
    Bosold, S.
    Engenhart-Cabillic, R.
    Sparenberg, J.
    Vorwerk, H.
    Zink, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (03) : 310 - 316
  • [6] Investigation of the dosimetric accuracy of the isocenter shifting method in prostate cancer patients with and without hip prostheses
    Hwang, Andrew B.
    Kinsey, Erica
    Xia, Ping
    MEDICAL PHYSICS, 2009, 36 (11) : 5221 - 5227
  • [7] Interindividual Differences in the Contouring of Target Volume and Risk Structures in Prostate Cancer
    Baier, Fabian
    Koelbl, Oliver
    Steger, Felix
    Hautmann, Matthias
    Allgaeuer, Michael
    Hipp, Matthias
    Eberl, Tanja
    Tobermann, Anja
    Knott, Bernadette
    Schneider, Polin
    Juniku, Nderim
    Wypior, Hans-Joachim
    Suess, Christoph
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 : S14 - S14
  • [8] Radiotherapy toxicity in prostate cancer patients with bilateral hip prostheses
    Fischer, A.
    Hoskin, P.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1090 - S1091
  • [9] CT/MRI IMAGE REGISTRATION IN PROSTATE RADIOTHERAPY PLANNING OF PATIENTS WITH UNI- AND BI-LATERAL HIP PROSTHESES
    Brunt, J.
    Haridass, A.
    Malik, Z.
    Vee, C. Eswar
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S184 - S184
  • [10] HDR brachytherapy of prostate patient in the presence of bi-lateral hip prostheses using megavoltage cone-beam CT
    Pouliot, J.
    Descovich, M.
    Aubin, M.
    Brady, M.
    Chan, A.
    Lometti, M.
    Morin, O.
    Speight, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2653 - 2653