Case of Legionnaires' disease in a neonate following a home birth in a heated birthing pool, England, June 2014

被引:7
作者
Phin, N. [1 ]
Cresswell, T. [1 ]
Parry-Ford, F. [1 ]
机构
[1] Publ Hlth England, London, England
关键词
LEGIONELLA-PNEUMONIA; WATER BIRTH; INFECTION;
D O I
10.2807/1560-7917.ES2014.19.29.20857
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Public Health England was notified of Legionnaires' disease in a neonate following a home birth in a heated birthing pool filled from the domestic hot water supply two weeks earlier. We describe the incident, sampling results, and public health actions. It is recommended that heated birthing pools should not be used for home births. Neonates developing pneumonia within 14 days of labour or birth in any birthing pool should be tested for Legionnaires' disease.
引用
收藏
页码:2 / 4
页数:3
相关论文
共 9 条
[1]   NOSOCOMIAL INFECTION WITH LEGIONELLA PNEUMOPHILA SEROGROUP-1 AND SEROGROUP-8 IN A NEONATE [J].
AUBERT, G ;
BORNSTEIN, N ;
RAYET, I ;
POZZETTO, B ;
LENORMAND, PH .
SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 1990, 22 (03) :367-370
[2]  
ECDC, 2014, LEG DIS EUR 2012
[3]   Legionella pneumophila pneumonia in a newborn after water birth:: A new mode of transmission [J].
Franzin, L ;
Scolfaro, C ;
Cabodi, D ;
Valera, M ;
Tovo, PA .
CLINICAL INFECTIOUS DISEASES, 2001, 33 (09) :E103-E104
[4]   Problem pathogens: paediatric legionellosis - implications for improved diagnosis [J].
Greenberg, David ;
Chiou, Christine C. ;
Famigilleti, Ronald ;
Lee, Tzieian C. ;
Yu, Victor L. .
LANCET INFECTIOUS DISEASES, 2006, 6 (08) :529-535
[5]  
Health Protection Agency (HPA), 2006, HSE DOC MAN SPA POOL
[6]   Neonatal sudden death due to Legionella pneumonia associated with water birth in a domestic spa bath [J].
Nagai, T ;
Sobajima, H ;
Iwasa, M ;
Tsuzuki, T ;
Kura, F ;
Amemura-Maekawa, J ;
Watanabe, H .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) :2227-2229
[7]  
Schrijver DK, 2002, VLAAMS INFECTIEZIEKT, P8
[8]   FATAL HOSPITAL-ACQUIRED LEGIONELLA PNEUMONIA IN A NEONATE [J].
Shachor-Meyouhas, Yael ;
Kassis, Imad ;
Bamberger, Ellen ;
Nativ, Tova ;
Sprecher, Hannah ;
Levy, Itzhak ;
Srugo, Isaac .
PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2010, 29 (03) :280-281
[9]   First Outbreak of Nosocomial Legionella Infection in Term Neonates Caused by a Cold Mist Ultrasonic Humidifier [J].
Yiallouros, Panayiotis K. ;
Papadouri, Thalia ;
Karaoli, Christina ;
Papamichael, Elena ;
Zeniou, Maria ;
Pieridou-Bagatzouni, Despo ;
Papageorgiou, Georgios T. ;
Pissarides, Nicolas ;
Harrison, Timothy G. ;
Hadjidemetriou, Andreas .
CLINICAL INFECTIOUS DISEASES, 2013, 57 (01) :48-56