Correction of 3D rigid body motion in fMRI time series by independent estimation of rotational and translational effects in k-space

被引:6
作者
Costagli, Mauro [1 ,2 ]
Waggoner, R. Allen [1 ]
Ueno, Kenichi [3 ]
Tanaka, Keiji [1 ]
Cheng, Kang [1 ,3 ]
机构
[1] RIKEN, Brain Sci Inst, Lab Cognit Brain Mapping, Wako, Saitama 3510198, Japan
[2] Univ Pisa, Lab Clin Biochem & Mol Biol, I-56100 Pisa, Italy
[3] RIKEN, Brain Sci Inst, Support Unit Funct Magnet Resonance Imaging, Wako, Saitama 3510198, Japan
关键词
fMRI; head motion; 3D registration; rotation correction; translational shift; Fourier transform; k-space; IERATIK; FUNCTIONAL MRI; IMAGE REGISTRATION; NAVIGATOR ECHOES; ALGORITHM; SOFTWARE;
D O I
10.1016/j.neuroimage.2008.12.067
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In functional magnetic resonance imaging (fMRI), even subvoxel motion dramatically corrupts the blood oxygenation level-dependent (BOLD) signal, invalidating the assumption that intensity variation in time is primarily due to neuronal activity. Thus, correction of the subject's head movements is a fundamental step to be performed prior to data analysis. Most motion correction techniques register a series of volumes assuming that rigid body motion, characterized by rotational and translational parameters, occurs. Unlike the most widely used applications for fMRI data processing, which correct motion in the image domain by numerically estimating rotational and translational components simultaneously, the algorithm presented here operates in a three-dimensional k-space, to decouple and correct rotations and translations independently, offering new ways and more flexible procedures to estimate the parameters of interest. We developed an implementation of this method in MATLAB, and tested it on both simulated and experimental data. Its performance was quantified in terms of square differences and center of mass stability across time. Our data show that the algorithm proposed here successfully corrects for rigid-body motion, and its employment in future fMRI studies is feasible and promising. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:749 / 757
页数:9
相关论文
共 21 条
[1]  
[Anonymous], 1975, PROC INT C CYBERN SO
[2]  
Bracewell R.N., 2000, FOURIER TRANSFORMATI, V3rd
[3]  
Calhoun V., 2000, Proceedings, ISMRM, 9th Annual Meeting, Denver, P810
[4]   AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages [J].
Cox, RW .
COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (03) :162-173
[5]   Improved image registration by using Fourier interpolation [J].
Eddy, WF ;
Fitzgerald, M ;
Noll, DC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :923-931
[6]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[7]  
Friston K., 1995, HUMAN BRAIN MAPPING, V2, P189, DOI DOI 10.1002/HBM.460020402
[8]   ORBITAL NAVIGATOR ECHOES FOR MOTION MEASUREMENTS IN MAGNETIC-RESONANCE-IMAGING [J].
FU, ZW ;
WANG, Y ;
GRIMM, RC ;
ROSSMAN, PJ ;
FELMLEE, JP ;
RIEDERER, SJ ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (05) :746-753
[9]   RETROSPECTIVE ESTIMATION AND CORRECTION OF PHYSIOLOGICAL FLUCTUATION IN FUNCTIONAL MRI [J].
HU, XP ;
LE, TH ;
PARRISH, T ;
ERHARD, P .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :201-212
[10]   Neuroimaging at 1.5 T and 3.0 T:: Comparison of oxygenation-sensitive magnetic resonance imaging [J].
Krüger, G ;
Kastrup, A ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :595-604