Improved Quality and Diagnostic Confidence Achieved by Use of Dose-Reduced Gadolinium Blood-Pool Agents for Time-Resolved Intracranial MR Angiography

被引:6
作者
Dehkharghani, S. [1 ]
Kang, J. [2 ]
Saindane, A. M. [1 ]
机构
[1] Emory Univ Hosp, Dept Radiol & Imaging Sci, Neuroradiol Div, Atlanta, GA 30322 USA
[2] Emory Univ, Rollins Sch Publ Hlth, Dept Biostat & Bioinformat, Atlanta, GA 30322 USA
关键词
MAGNETIC-RESONANCE ANGIOGRAPHY; GADOFOSVESET TRISODIUM; GADOPENTETATE DIMEGLUMINE; CONTRAST AGENT; GADOBENATE DIMEGLUMINE; TESLA; 1ST-PASS; MS-325; RELAXIVITY; EFFICACY;
D O I
10.3174/ajnr.A3693
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Time-resolved MRA with the use of bolus injection of paramagnetic agents has proved valuable in neurovascular imaging. Standard contrast agents have limited blood-pool residence times, motivating the development of highly protein-bound blood-pool agents with greater relaxivity and longer intravascular residence, affording improved image quality at lesser doses. This study represents the first comparison of blood-pool agents to standard agents in time-resolved cerebral MRA. MATERIALS AND METHODS: One hundred datasets were acquired at 1.5T by use of a standardized, time-resolved MRA protocol. Patients received either unit dosing of a standard extracellular agent at 0.1 mmol/kg or a blood-pool agent at 0.03 mmol/kg. Peak arterial and venous enhancement phases were identified and subsequently scored qualitatively by use of a 4-point Likert scale, with attention to 6 vascular segments: 1) intracranial ICA; 2) MCA M1; 3) MCA M2; 4) MCA M3; 5) deep cerebral veins; and 6) dural venous sinuses. RESULTS: Fifty MR angiographies were acquired with each agent. No significant differences were found between agents in generation of uncontaminated arteriograms. Blood-pool agents, at 67% dose reduction, were of significantly greater quality across most vascular segments, including ICA (P = .019), M2 (P = .003), and M3 (P < .01). Superiority in the M1 segment approached significance (P = .059). Significantly better venographic quality was noted for deep venous structures (P = .016) with the use of blood-pool agents. CONCLUSIONS: Blood-pool agents provide superior demonstration of most intracranial vessels in time-resolved MRA compared with standard agents, at reduced doses. The greater relaxation enhancement and more favorable dosing profile make blood-pool agents superior to standard agents for use in cerebral time-resolved MRA.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 26 条
[1]   A serial dilution study of gadolinium-based MR imaging contrast agents [J].
Bleicher, A. G. ;
Kanal, E. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) :668-673
[2]   Carotid MR angiography: Phase II study of safety and efficacy for MS-325 [J].
Bluemke, DA ;
Stillman, AE ;
Bis, KG ;
Grist, TM ;
Baum, RA ;
D'Agostino, R ;
Malden, ES ;
Pierro, JA ;
Yucel, EK .
RADIOLOGY, 2001, 219 (01) :114-122
[3]   The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates [J].
Caravan, P ;
Cloutier, NJ ;
Greenfield, MT ;
McDermid, SA ;
Dunham, SU ;
Bulte, JWM ;
Amedio, JC ;
Looby, RJ ;
Supkowski, RM ;
Horrocks, WD ;
McMurry, TJ ;
Lauffer, RB .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (12) :3152-3162
[4]   Gadolinium-enhanced MR imaging and nephrogenic systemic fibrosis: Retrospective study of a renal replacement therapy cohort [J].
Collidge, Tara Anne ;
Thomson, Peter Campbell ;
Mark, Patrick Barry ;
Traynor, James Phillip ;
Jardine, Alan George ;
Morris, Scott Thomas William ;
Simpson, Keith ;
Roditi, Giles Hannibal .
RADIOLOGY, 2007, 245 (01) :168-175
[5]   Comparison of Gadofosveset Trisodium and Gadobenate Dimeglumine During Time-Resolved Thoracic MR Angiography at 3T [J].
Frydrychowicz, Alex ;
Russe, Maximilian F. ;
Bock, Jelena ;
Stalder, Aurelien F. ;
Bley, Thorsten A. ;
Harloff, Andreas ;
Markl, Michael .
ACADEMIC RADIOLOGY, 2010, 17 (11) :1394-1400
[6]   Peripheral MR Angiography with Blood Pool Contrast Agent: Prospective Intraindividual Comparative Study of High-Spatial-Resolution Steady-State MR Angiography versus Standard-Resolution First-Pass MR Angiography and DSA [J].
Hadizadeh, Dariusch R. ;
Gieseke, Juergen ;
Lohmaier, Stefan H. ;
Wilhelm, Kai ;
Boschewitz, Jack ;
Verrel, Frauke ;
Schild, Hans H. ;
Willinek, Winfried A. .
RADIOLOGY, 2008, 249 (02) :701-711
[7]   Initial imaging recommendations for Wasovist angiography [J].
Hartmann, M ;
Wiethoff, AJ ;
Hentrich, HR ;
Rohrer, M .
EUROPEAN RADIOLOGY, 2006, 16 :B15-B23
[8]  
Kiefer C, 2009, IFMBE PROC, V25, P466, DOI 10.1007/978-3-642-03879-2_131
[9]   First-pass whole-body magnetic resonance angiography (MRA) using the blood-pool contrast medium gadofosveset trisodium - Comparison to gadopentetate dimeglumine [J].
Klessen, Christian ;
Hein, Patrick A. ;
Huppertz, Alexander ;
Voth, Matthias ;
Wagner, Moritz ;
Elgeti, Thomas ;
Kroll, Hannes ;
Hamm, Bernd ;
Taupitz, Matthias ;
Asbach, Patrick .
INVESTIGATIVE RADIOLOGY, 2007, 42 (09) :659-664
[10]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351