Examining National Outcomes after Thyroidectomy with Nerve Monitoring

被引:28
|
作者
Chung, Thomas K. [1 ]
Rosenthal, Eben L. [1 ]
Porterfield, John R. [2 ]
Carroll, William R. [1 ]
Richman, Joshua [2 ]
Hawn, Mary T. [2 ]
机构
[1] Univ Alabama Birmingham, Dept Surg, Div Otolaryngol Head & Neck Surg, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Surg, Birmingham, AL 35294 USA
关键词
RECURRENT LARYNGEAL NERVE; PARATHYROID SURGERY; PARALYSIS; PATTERNS; TRENDS; RISK;
D O I
10.1016/j.jamcollsurg.2014.04.013
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: Previous intraoperative nerve monitoring (IONM) studies have demonstrated modest-to-no benefit and did not include a nationwide sample of hospitals representative of broad thyroidectomy practices. This national study was designed to compare vocal cord paralysis (VCP) rates between thyroidectomy with IONM and without monitoring (conventional). STUDY DESIGN: We performed a retrospective analysis of 243,527 thyroidectomies during 2008 to 2011 using the Nationwide Inpatient Sample. RESULTS: Use of IONM increased yearly throughout the study period (2.6% [2008], 5.6% [2009], 6.1% [2010], 6.9% [2011]) and during this time, VCP rates in the IONM group initially increased year-over-year (0.9% [2008], 2.4% [2009], 2.5% [2010], 1.4% [2011]). In un-adjusted analyses, IONM was associated with significantly higher VCP rates (conventional 1.4% vs IONM 1.9%, p < 0.001). After propensity score matching, IONM remained associated with higher VCP rates in partial thyroidectomy and lower VCP rates for total thyroidectomy with neck dissection. Hospital-level analysis revealed that VCP rates were not explained by differential laryngoscopy rates, decreasing the likelihood of ascertainment bias. Additionally, for hospitals in which IONM was applied to more than 50% of thyroidectomies, lower VCP rates were observed (1.1%) compared with hospitals that applied IONM to less than 50% (1.6%, p = 0.016). Higher hospital volume correlated with lower VCP rates in both groups (< 75, 75 to 299, >300 thyroidectomies/year: IONM, 2.1%, 1.7%, 1.7%; conventional, 1.5%, 1.3%, 1.0%, respectively). CONCLUSIONS: According to this study, IONM has not been broadly adopted into practice. Overall, IONM was associated with a higher rate of VCP even after correction for numerous confounders. In particular, low institutional use of IONM and use in partial thyroidectomies are associated with higher rates of VCP. Further studies are warranted to support the broader application of IONM in patients where benefit can be reliably achieved. (C) 2014 by the American College of Surgeons
引用
收藏
页码:765 / 770
页数:6
相关论文
共 50 条
  • [41] Voice Changes after Late Recurrent Laryngeal Nerve Identification Thyroidectomy
    Elsheikh, Ezzeddin
    Quriba, Amal Saeed
    El-Anwar, Mohammad Waheed
    JOURNAL OF VOICE, 2016, 30 (06) : 762.e1 - 762.e9
  • [42] Increased prevalence of neural monitoring during thyroidectomy: Global surgical survey
    Feng, Allen L.
    Puram, Sidharth, V
    Singer, Michael C.
    Modi, Rahul
    Kamani, Dipti
    Randolph, Gregory W.
    LARYNGOSCOPE, 2020, 130 (04) : 1097 - 1104
  • [43] Voice Changes Without Laryngeal Nerve Alterations After Thyroidectomy: The Need For Prospective Trials - A Review Study
    Beka, Ervin
    Gimm, Oliver
    JOURNAL OF VOICE, 2024, 38 (01) : 231 - 238
  • [44] Laryngeal Nerve Monitoring: Current Utilization among Head and Neck Surgeons
    Singer, Michael C.
    Rosenfeld, Richard M.
    Sundaram, Krishnamurthi
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2012, 146 (06) : 895 - 899
  • [45] Stimulation Threshold Greatly Affects the Predictive Value of Intraoperative Nerve Monitoring
    Faden, Daniel L.
    Orloff, Lisa A.
    Ayeni, Tokunbo
    Fink, Daniel S.
    Yung, Katherine
    LARYNGOSCOPE, 2015, 125 (05) : 1265 - 1270
  • [46] Intraoperative nerve monitoring in thyroid and parathyroid surgery: a decade of Italian practice
    Melcarne, R.
    Docimo, G.
    Aiello, P. S. L.
    Andreani, S.
    Avenia, N.
    Basili, G.
    Bellotti, C.
    Bettini, D.
    Biffoni, M.
    Bononi, M.
    Bove, A.
    Calo, P. G.
    Casaril, A.
    Cavallaro, G.
    Chiofalo, M. G.
    Consorti, F.
    De Crea, C.
    De Pasquale, L.
    Del Rio, P.
    Dobrinja, C.
    Giacomelli, L.
    Graceffa, G.
    Gurrado, A.
    Iacobone, M.
    Innaro, N.
    Leopaldi, E.
    Lupone, G.
    Materazzi, G.
    Minuto, M.
    Mullineris, B.
    Palestini, N.
    Panconesi, R.
    Pauna, I.
    Pezzolla, A.
    Pisano, I. P.
    Princi, P.
    Quaglino, F.
    Raffaelli, M.
    Rosato, L.
    Sartori, P. V.
    Scerrino, G.
    Scolari, F.
    Testini, M.
    Traini, E.
    Boniardi, M.
    UPDATES IN SURGERY, 2025,
  • [47] Importance of latency and amplitude values of recurrent laryngeal nerve during thyroidectomy in diabetic patients
    Ozemir, Ibrahim Ali
    Ozyalvac, Ferman
    Yildiz, Gorkem
    Eren, Tunc
    Aydin-Ozemir, Zeynep
    Alimoglu, Orhan
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 35 : 172 - 178
  • [48] Long-Term Voice Outcomes After Robotic Thyroidectomy
    Chang Myeon Song
    Bo Ram Yun
    Yong Bae Ji
    Eui Suk Sung
    Kyung Rae Kim
    Kyung Tae
    World Journal of Surgery, 2016, 40 : 110 - 116
  • [49] Visual identification or the recurrent laryngeal nerve during thyroidectomy
    Procacciante, Fabio
    Diamantini, Giulia
    Caciolo, Fabiana
    Abilaliaj, Valmira
    ANNALI ITALIANI DI CHIRURGIA, 2011, 82 (04) : 261 - 265
  • [50] Association of Surgeon Volume With Outcomes and Cost Savings Following Thyroidectomy A National Forecast
    Al-Qurayshi, Zaid
    Robins, Russell
    Hauch, Adam
    Randolph, Gregory W.
    Kandil, Emad
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2016, 142 (01) : 32 - 39