Dosimetric errors during treatment of centrally located lung tumors with stereotactic body radiation therapy: Monte Carlo evaluation of tissue inhomogeneity corrections

被引:10
作者
Altunbas, Cem [1 ]
Kavanagh, Brian [1 ]
Dzingle, Wayne [1 ]
Stuhr, Kelly [1 ]
Gaspar, Laurie [1 ]
Miften, Moyed [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiat Oncol, Aurora, CO 80045 USA
关键词
Inhomogeneity corrections; Monte Carlo; Pencil beam; Lung SBRT; DOSE CALCULATION; RADIOTHERAPY; ALGORITHM; CANCER; DISTRIBUTIONS; MODEL; SBRT; VMC;
D O I
10.1016/j.meddos.2013.06.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Early experience with stereotactic body radiation therapy (SBRT) of centrally located lung tumors indicated increased rate of high-grade toxicity in the lungs. These clinical results were based on treatment plans that were computed using pencil beam-like algorithms and without tissue inhomogeneity corrections. In this study, we evaluated the dosimetric errors in plans with and without inhomogeneity corrections and with planning target volumes (PTVs) that were within the zone of the proximal bronchial tree (BT). For 10 patients, the PTV, lungs, and sections of the BT either inside or within 2 cm of the PTV were delineated. Two treatment plans were generated for each patient using the following dose-calculation methods: (1) pencil beam (PB) algorithm without inhomogeneity correction (IC) (PB - IC) and (2) PB with inhomogeneity correction (PB + IC). Both plans had identical beam geometry but different beam segment shapes and monitor units (MU) to achieve similar conformal dose coverage of PTV. To obtain the baseline dose distributions, each plan was recalculated using a Monte Carlo (MC) algorithm by keeping MUs the same in the respective plans. The median maximum dose to the proximal BT and PTV dose coverage in the PB + IC plans were overestimated by 8% and 11%, respectively. However, the median maximum dose to the proximal BT and PTV dose coverage in PB - IC plans were underestimated by 15% and 9%. Similar trends were observed in low-dose regions of the lung within the irradiated volume. Our study indicates that dosimetric bias introduced by unit tissue density plans cannot be characterized as underestimation or overestimation of dose without taking the tumor location into account. This issue should be considered when analyzing clinical toxicity data from early lung SBRT trials that utilized unit tissue density for dose calculations. (C) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:436 / 441
页数:6
相关论文
共 23 条
[1]   Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy [J].
Ding, George X. ;
Duggan, Dennis M. ;
Lu, Bo ;
Hallahan, Dennis E. ;
Cmelak, Anthony ;
Malcolm, Arnold ;
Newton, Jared ;
Deeley, Matthew ;
Coffey, Charles W. .
MEDICAL PHYSICS, 2007, 34 (07) :2985-2994
[2]   Investigation of a new Monte Carlo and a pencil beam algorithm in a heterogeneous thorax phantom [J].
Ding, M. ;
Newman, F. ;
Stuhr, K. ;
Rice, H. ;
Hu, A. ;
Kavanagh, B. D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01) :S636-S636
[3]   Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm [J].
Fippel, M .
MEDICAL PHYSICS, 1999, 26 (08) :1466-1475
[4]   On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities:: comparison with Monte Carlo calculations [J].
Fogliata, Antonella ;
Vanetti, Eugenio ;
Albers, Dirk ;
Brink, Carsten ;
Clivio, Alessandro ;
Knoos, Tommy ;
Nicolini, Giorgia ;
Cozzi, Luca .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05) :1363-1385
[5]   Dose-response relationship for radiation-induced pneumonitis after pulmonary stereotactic body radiotherapy [J].
Guckenberger, Matthias ;
Baier, Kurt ;
Polat, Buelent ;
Richter, Anne ;
Krieger, Thomas ;
Wilbert, Juergen ;
Mueller, Gerd ;
Flentje, Michael .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (01) :65-70
[6]   Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targets [J].
Haedinger, U ;
Krieger, T ;
Flentje, M ;
Wulf, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01) :239-249
[7]   The effect of dose calculation accuracy on inverse treatment planning [J].
Jeraj, R ;
Keall, PJ ;
Siebers, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (03) :391-407
[8]   The dosimetric effect of inhomogeneity correction in dynamic conformal arc stereotactic body radiation therapy for lung tumors [J].
Kavanagh, Brian ;
Ding, Meisong ;
Schefter, Tracey ;
Stuhr, Kelly ;
Newman, Francis .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (02) :58-63
[9]   3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) [J].
Kawrakow, I ;
Fippel, M ;
Friedrich, K .
MEDICAL PHYSICS, 1996, 23 (04) :445-457
[10]   LIMITATIONS OF A PENCIL BEAM APPROACH TO PHOTON DOSE CALCULATIONS IN LUNG-TISSUE [J].
KNOOS, T ;
AHNESJO, A ;
NILSSON, P ;
WEBER, L .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (09) :1411-1420