A Real-TimeWireless Sweat Rate Measurement System for Physical Activity Monitoring

被引:43
作者
Brueck, Andrew [1 ]
Iftekhar, Tashfin [1 ]
Stannard, Alicja B. [2 ]
Yelamarthi, Kumar [1 ]
Kaya, Tolga [3 ]
机构
[1] Cent Michigan Univ, Sch Engn & Technol, Mt Pleasant, MI 48859 USA
[2] Sacred Heart Univ, Dept Phys Therapy & Human Movement Sci, Fairfield, CT 06825 USA
[3] Sacred Heart Univ, Sch Comp, Fairfield, CT 06825 USA
基金
美国国家科学基金会;
关键词
sweat sensor; sweat rate; dehydration; IoT; PDMS; EXERCISE; PERFORMANCE; SENSORS; PATCH; COLLECTION; HUMANS; SODIUM;
D O I
10.3390/s18020533
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There has been significant research on the physiology of sweat in the past decade, with one of the main interests being the development of a real-time hydration monitor that utilizes sweat. The contents of sweat have been known for decades; sweat provides significant information on the physiological condition of the human body. However, it is important to know the sweat rate as well, as sweat rate alters the concentration of the sweat constituents, and ultimately affects the accuracy of hydration detection. Towards this goal, a calorimetric based flow-rate detection system was built and tested to determine sweat rate in real time. The proposed sweat rate monitoring system has been validated through both controlled lab experiments (syringe pump) and human trials. An Internet of Things (IoT) platform was embedded, with the sensor using a Simblee board and Raspberry Pi. The overall prototype is capable of sending sweat rate information in real time to either a smartphone or directly to the cloud. Based on a proven theoretical concept, our overall system implementation features a pioneer device that can truly measure the rate of sweat in real time, which was tested and validated on human subjects. Our realization of the real-time sweat rate watch is capable of detecting sweat rates as low as 0.15 mu L/min/cm(2), with an average error in accuracy of 18% compared to manual sweat rate readings.
引用
收藏
页数:12
相关论文
共 38 条
[1]  
Abdelgawad A., 2016, P 2 EAI INT C SMART
[2]   Heart rate monitoring - Applications and limitations [J].
Achten, J ;
Jeukendrup, AE .
SPORTS MEDICINE, 2003, 33 (07) :517-538
[3]   A portable optical human sweat sensor [J].
Al-omari, Mahmoud ;
Liu, Gengchen ;
Mueller, Anja ;
Mock, Adam ;
Ghosh, Ruby N. ;
Smith, Kyle ;
Kaya, Tolga .
JOURNAL OF APPLIED PHYSICS, 2014, 116 (18)
[4]   Detection of relative [Na+] and [K+] levels in sweat with optical measurements [J].
Al-Omari, Mahmoud ;
Sel, Kivanc ;
Mueller, Anja ;
Edwards, Jeffery ;
Kaya, Tolga .
JOURNAL OF APPLIED PHYSICS, 2014, 115 (20)
[5]  
[Anonymous], LILYPAD SIMBL BLE BO
[6]   Describing individual variation in local sweating during exercise in a temperate environment [J].
Bain, Anthony R. ;
Deren, Tomasz M. ;
Jay, Ollie .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (08) :1599-1607
[7]   Comparison of regional patch collection vs. whole body washdown for measuring sweat sodium and potassium loss during exercise [J].
Baker, Lindsay B. ;
Stofan, John R. ;
Hamilton, Adam A. ;
Horswill, Craig A. .
JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (03) :887-895
[8]   Non-invasive wearable electrochemical sensors: a review [J].
Bandodkar, Amay J. ;
Wang, Joseph .
TRENDS IN BIOTECHNOLOGY, 2014, 32 (07) :363-371
[9]   Sodium ion concentration vs. sweat rate relationship in humans [J].
Buono, Michael J. ;
Ball, Kimberly D. ;
Kolkhorst, Fred W. .
JOURNAL OF APPLIED PHYSIOLOGY, 2007, 103 (03) :990-994
[10]  
Casa DJ, 2000, J ATHL TRAINING, V35, P212