Viscoelastic memory and self-expansion of self-reinforced bioabsorbable stents

被引:25
作者
Välimaa, T
Laaksovirta, S
Tammela, TLJ
Laippala, P
Talja, M
Isotalo, T
Pétas, A
Tarri, K
Törmälä, P
机构
[1] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
[2] Tampere Univ Hosp, Div Urol, FIN-33521 Tampere, Finland
[3] Univ Tampere, Sch Publ Hlth, FIN-33101 Tampere, Finland
[4] Tampere Univ Hosp, Res Unit, FIN-33101 Tampere, Finland
[5] Paijat Hame Cent Hosp, Dept Surg, FIN-15850 Lahti, Finland
[6] Univ Helsinki Hosp, Dept Urol, FIN-00290 Helsinki, Finland
关键词
bioabsorbable; polymer; stents; viscoelastic memory; self-expansion;
D O I
10.1016/S0142-9612(02)00076-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The possibility to decide the speed and rate of expansion of stents is of great clinical importance by reason of the varying requirements for different indications to use stents. Self-reinforced bioabsorbable stents can be made self-expanding owing to the viscoelastic memory of the material. Sterns are stable at room temperature and expansion occurs at body temperature. The level at which the expansion stops depends on the material, crystallinity, initial diameter of spiral and annealing temperature. The expansion rate can be estimated by logarithmic equation, if material, draw ratio and diameter of stent wire are constant. This is, however, possible only if processing parameters are constant. Based on the present results annealing temperature and expansion time were seen to be directly proportional to the expansion rate of the stent. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3575 / 3582
页数:8
相关论文
共 19 条
[1]   LONG-TERM CONSEQUENCES OF URETHRAL STENTS [J].
BAERT, L ;
VERHAMME, L ;
VANPOPPEL, H ;
VANDEURSEN, H ;
BAERT, J .
JOURNAL OF UROLOGY, 1993, 150 (03) :853-855
[2]  
COLT H, 1995, INTERVENT PULMONOL, V3, P465
[3]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+
[4]  
FABIAN KM, 1980, UROLOGE A, V19, P236
[5]  
FISHER EW, 1973, KOLLOID Z Z POLYM, V251, P980
[6]   INVITRO CHEMICAL DEGRADATION OF POLY(GLYCOLIC ACID) PELLETS AND FIBERS [J].
GINDE, RM ;
GUPTA, RK .
JOURNAL OF APPLIED POLYMER SCIENCE, 1987, 33 (07) :2411-2429
[7]   A bioabsorbable self-expandable, self-reinforced poly-L-lactic acid urethral stent for recurrent urethral strictures:: A preliminary report [J].
Isotalo, T ;
Tammela, TLJ ;
Talja, M ;
Välimaa, T ;
Törmälä, P .
JOURNAL OF UROLOGY, 1998, 160 (06) :2033-2036
[8]   A STUDY OF THE GEOMETRICAL AND MECHANICAL-PROPERTIES OF A SELF-EXPANDING METALLIC STENT THEORY AND EXPERIMENT [J].
JEDWAB, MR ;
CLERC, CO .
JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (01) :77-85
[9]   Common bile duct obstruction due to malignancy: Treatment with plastic versus metal stents [J].
Lammer, J ;
Hausegger, KA ;
Fluckiger, F ;
Winkelbauer, FW ;
Wilding, R ;
Klein, GE ;
Thurnher, SA ;
Havelec, L .
RADIOLOGY, 1996, 201 (01) :167-172
[10]   Self-expanding metallic coil stents for palliation of esophageal carcinoma: Two cases of decisive stent dysfunction [J].
Loser, C ;
Folsch, UR .
ENDOSCOPY, 1996, 28 (06) :514-517