The combined effects of undersized drilling and implant macrogeometry on bone healing around dental implants: an experimental study

被引:68
作者
Jimbo, R. [1 ]
Tovar, N. [2 ]
Anchieta, R. B. [2 ]
Machado, L. S. [2 ]
Marin, C. [3 ]
Teixeira, H. S. [2 ]
Coelho, P. G. [2 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, S-20506 Malmo, Sweden
[2] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY USA
[3] UNIGRANRIO, Dept Dent, Duque De Caxias, RJ, Brazil
关键词
undersized preparation; conical implants; cylindrical implants; PRIMARY STABILITY; INSERTION TORQUE; TITANIUM IMPLANTS; SECONDARY STABILITY; SURGICAL TECHNIQUES; PLACED IMPLANTS; DENSITY; DOGS; QUALITY; DESIGNS;
D O I
10.1016/j.ijom.2014.03.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study investigated the effect of undersized preparations with two different implant macrogeometries. There were four experimental groups: group 1, conical implant with an undersized osteotomy of 3.2 mm; group 2, conical implant with an undersized osteotomy of 3.5 mm; group 3, cylindrical implant with an undersized osteotomy of 3.2 mm; group 4, cylindrical implant with an undersized osteotomy of 3.5 mm. Implants were placed in one side of the sheep mandible (n = 6). After 3 weeks, the same procedure was conducted on the other side; 3 weeks later, euthanasia was performed. All implants were 4 mm x 10 mm Insertion torque was recorded for all implants during implantation. Retrieved samples were subjected to histological sectioning and histomorphometry. Implants of groups 1 and 2 presented significantly higher insertion torque than those of groups 3 and 4 (P < 0.001). No differences in bone-to-implant contact or bone area fraction occupied were observed between the groups at 3 weeks (P > 0.24, and P > respectively), whereas significant differences were observed at 6 weeks between groups 1 and 2, and between groups 3 and 4 (P < 0.01). Undersized drilling affected the biological establishment of bone formation around both dental implant macrogeometries.
引用
收藏
页码:1269 / 1275
页数:7
相关论文
共 27 条
[1]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[2]   Effect of Drilling Dimension on Implant Placement Torque and Early Osseointegration Stages: An Experimental Study in Dogs [J].
Campos, Felipe E. ;
Gomes, Julio B. ;
Marin, Charles ;
Teixeira, Hellen S. ;
Suzuki, Marcelo ;
Witek, Lukasz ;
Zanetta-Barbosa, Darceny ;
Coelho, Paulo G. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (01) :E43-E50
[3]   Biomechanical evaluation of macro and micro designed screw-type implants: an insertion torque and removal torque study in rabbits [J].
Chowdhary, Ramesh ;
Jimbo, Ryo ;
Thomsen, Christian ;
Carlsson, Lennart ;
Wennerberg, Ann .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (03) :342-346
[4]   Evaluation of Stress Pattern Generated Through Various Thread Designs of Dental Implants Loaded in a Condition of Immediately After Placement and on Osseointegration-An FEA Study [J].
Chowdhary, Ramesh ;
Halldin, Anders ;
Jimbo, Ryo ;
Wennerberg, Ann .
IMPLANT DENTISTRY, 2013, 22 (01) :91-96
[5]   The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: An experimental study in dogs [J].
Coelho, Paulo G. ;
Granato, Rodrigo ;
Marin, Charles ;
Teixeira, Hellen S. ;
Suzuki, Marcelo ;
Valverde, Guilherme B. ;
Janal, Malvin N. ;
Lilin, Tomas ;
Bonfante, Estevam A. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (08) :1974-1981
[6]   Early Bone Healing around Different Implant Bulk Designs and Surgical Techniques: A Study in Dogs [J].
Coelho, Paulo G. ;
Suzuki, Marcelo ;
Guimaraes, Marcia V. M. ;
Marin, Charles ;
Granato, Rodrigo ;
Gil, Jose N. ;
Miller, Robert J. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (03) :202-208
[7]   A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE [J].
DONATH, K ;
BREUNER, G .
JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) :318-326
[8]   The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants [J].
dos Santos, Mychelle Vianna ;
Elias, Carlos Nelson ;
Cavalcanti Lima, Jose Henrique .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (03) :215-223
[9]   Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants [J].
Elias, Carlos Nelson ;
Rocha, Felipe Assis ;
Nascimento, Ana Lucia ;
Coelho, Paulo Guilherme .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 16 :169-180
[10]   IDENTIFICATION OF BONE QUALITY IN CONJUNCTION WITH INSERTION OF TITANIUM IMPLANTS - A PILOT-STUDY IN JAW AUTOPSY SPECIMENS [J].
FRIBERG, B ;
SENNERBY, L ;
ROOS, J ;
LEKHOLM, U .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (04) :213-219