A cementless hip system with a new surface for osseous integration

被引:11
作者
Lass, Richard [1 ]
Kolb, Alexander [1 ]
Skrbensky, Gobert [1 ]
Reinisch, Georg [2 ]
Kubista, Bernd [1 ]
Giurea, Alexander [1 ]
Windhager, Reinhard [1 ]
Kotz, Rainer [1 ]
机构
[1] Med Univ Vienna, Dept Orthopaed & Orthopaed Surg, A-1090 Vienna, Austria
[2] Vienna Univ Technol, Dept Microtech & Precis Engn, A-1040 Vienna, Austria
关键词
Total hip arthroplasty; Cementless stem; Contamination-free surface; Radiographic analysis; Clinical outcome; CONCISE FOLLOW-UP; TITANIUM ZWEYMULLER STEM; FEMORAL COMPONENTS; ARTHROPLASTY; IMPLANTS; PARTICLES; REPLACEMENT; MINIMUM; ALLOY; ARTHRITIS;
D O I
10.1007/s00264-013-2135-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The failure of total hip systems caused by wear-particle-induced loosening has focused interest on factors potentially affecting wear rate. Remnants of the blasting material were reported on grit-blasted surfaces for cementless fixation. These particles are believed to cause third-body wear and implant loosening. The purpose of this study was to evaluate the early clinical and radiological outcomes of a cementless hip system with a new, contamination-free, roughened surface with regard to prosthesis-related failures. Between May 2004 and March 2009, 202 consecutive primary total hip arthroplasties (THAs) (192 patients with a mean age of 62.6 years) were performed using a cementless stem (HipstarA (R)) and a hemispherical acetabular cup (TridentA (R)). At a minimum follow-up of two years, five revisions (2.5 %) due to aseptic loosening of the stem and three (1.5 %) of the cup were necessary. The cumulative rate of prostheses survival, counting revision of both components and with aseptic failure as end point, was 92.9 % at 8.8 years. Radiolucent lines up to three millimetres were evaluated in the proximal part of the femur in 61 % of cases. Although the incidence of radiolucent lines was decreased, the revision rate was considerably increased compared to other uncemented hip implants with grit-blasted surfaces in the short- to mid-term follow-up of our study. Subsequent studies are needed to confirm whether these changes in implant material and surface affect the radiological and clinical outcome in the long term.
引用
收藏
页码:703 / 709
页数:7
相关论文
共 29 条
[1]  
BAUER TW, 1994, CLIN ORTHOP RELAT R, P11
[2]   Cementless total hip replacement: a prospective clinical study of the early functional and radiological outcomes of three different hip stems [J].
Bergschmidt, Philipp ;
Bader, Rainer ;
Finze, Susanne ;
Gankovych, Alexander ;
Kundt, Guenther ;
Mittelmeier, Wolfram .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (01) :125-133
[3]   Adverse tissue reactions to wear particles form Co-alloy articulations, increased by alumina-blasting particle contamination from cementless Ti-based total hip implants -: A report of seven revisions with early failure [J].
Böhler, M ;
Kanz, F ;
Schwarz, B ;
Steffan, I ;
Walter, A ;
Plenk, H ;
Knahr, K .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :128-136
[4]   Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement [J].
Bugbee, WD ;
Culpepper, WJ ;
Engh, CA ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1007-1012
[5]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]   Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports [J].
Della Valle, Craig J. ;
Mesko, Nathan W. ;
Quigley, Laura ;
Rosenberg, Aaron G. ;
Jacobs, Joshua J. ;
Galante, Jorge O. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (05) :1130-1135
[7]   Hydroxyapatite Coated Femoral Stems in Primary Total Hip Arthroplasty A Meta-Analysis [J].
Gandhi, Rajiv ;
Davey, J. Roderick ;
Mahomed, Nizar N. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (01) :38-42
[8]   Characterization, quantification, and isolation of aluminum oxide particles on grit blasted titanium aluminum alloy hip implants [J].
Gruebl, Alexander ;
Kolb, Alexander ;
Reinisch, Georg ;
Fafilek, Guenter ;
Skrbensk, Gobert ;
Kotz, Rainer .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 83B (01) :127-131
[9]   Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem -: A concise follow-up, at a minimum of fifteen years, of a previous report [J].
Gruebl, Alexander ;
Chiari, Catharina ;
Giurea, Alexander ;
Gruber, Martin ;
Kaider, Alexandra ;
Marker, Martina ;
Zehetgruber, Harald ;
Gottsauner-Wolf, Florian .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2210-2215
[10]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17