Multipurpose Navigation System-Based Concept for Surgical Template Production

被引:7
作者
Widmann, Gerlig [1 ]
Widmann, Roland [2 ]
Stoffner, Rudolf
Widmann, Ekkehard
Rieger, Thomas
Remensberger, Sabine
Grubwieser, Gert
Puelacher, Wolfgang [3 ]
Bale, Reto [1 ]
机构
[1] Innsbruck Med Univ, Dept Microinvas Therapy, Dept Radiol, A-6020 Innsbruck, Austria
[2] Roland Widmann Dent ROWIDENT Dent Lab, Oberndorf In Tirol, Austria
[3] Innsbruck Med Univ, Dept Craniomaxillofacial Surg, A-6020 Innsbruck, Austria
关键词
ENDOSSEOUS ORAL IMPLANTS; COMPUTER-AIDED NAVIGATION; DENTAL IMPLANTS; IN-VITRO; PROSTHESIS CONSTRUCTION; CLINICAL-EXPERIENCE; PLANNING SYSTEM; PLACEMENT; ACCURACY; SURGERY;
D O I
10.1016/j.joms.2008.12.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: We present a concept that uses the multipurpose navigation equipment of a university hospital for computed tomography (CT)-guided surgical template production, to improve the preclinical accuracy of the templates. Materials and Methods: Oral implants are planned on CT images with respect to the prosthodontic goal and anatomical considerations. Registration is performed via a modified Vogele-Bale-Hohner (VBH) mouthpiece (Medical Intelligence GmbH, Schwabmuenchen, Germany) and an external registration frame. In the laboratory, an optical navigation system is used to transfer the plan to the patient's registered dental stone cast for Surgical template production. During preclinical evaluation, duplicated stone casts were drilled via the obtained surgical templates. Accuracy was evaluated by matching the preoperative CT to the CT of the drilled stone casts. Results: Compared with present registration mouthpieces, the VBH mouthpiece requires only the dental impression of the patient's stone cast. In contrast to surgical navigation, an aiming device is used for navigated trajectory-alignment at the best technical level. There is no need for a positioning device, and the template can be immediately fabricated in a standard laboratory. The accuracy of 5 surgical templates showed a maximum normal deviation of 1.4 mm, and maximum angular deviations of 2.8 degrees. Conclusion: The presented concept allows for successful production of CT-guided surgical templates, and may show sufficient accuracy for clinical use. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:1113-1120, 2009
引用
收藏
页码:1113 / 1120
页数:8
相关论文
共 56 条
[1]   Navigated CT-guided interventions [J].
Bale, Reto ;
Widmann, Gerlig .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2007, 16 (04) :196-204
[2]  
Balshi Stephen F, 2006, J Esthet Restor Dent, V18, P312, DOI 10.1111/j.1708-8240.2006.00029.x
[3]  
Balshi SF, 2006, INT J PERIODONT REST, V26, P239
[4]   Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography [J].
Besimo, CE ;
Lambrecht, JT ;
Guindy, JS .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) :46-51
[5]   Computer-enhanced stereoscopic vision in a head-mounted operating binocular [J].
Birkfellner, W ;
Figl, M ;
Matula, C ;
Hummuel, J ;
Hanel, R ;
Imhof, H ;
Wanschitz, F ;
Wagner, A ;
Watzinger, F ;
Bergmann, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (03) :N49-N57
[6]   A head-mounted operating binocular for augmented reality visualization in medicine - Design and initial evaluation [J].
Birkfellner, W ;
Figl, M ;
Huber, K ;
Watzinger, F ;
Wanschitz, F ;
Hummel, J ;
Hanel, R ;
Greimel, W ;
Homolka, P ;
Ewers, R ;
Bergmann, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :991-997
[7]  
BouSerhal Charbel, 2002, Clin Implant Dent Relat Res, V4, P156, DOI 10.1111/j.1708-8208.2002.tb00167.x
[8]  
Di Giacomo GAP, 2005, J PERIODONTOL, V76, P503
[9]  
Dula K, 2001, INT J ORAL MAX IMPL, V16, P80
[10]   Basic research and 12 years of clinical experience in computer-assisted navigation technology: a review [J].
Ewers, R ;
Schicho, K ;
Undt, G ;
Wanschitz, F ;
Truppe, M ;
Seemann, R ;
Wagner, A .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (01) :1-8