Desiccant-based AHU interacting with a CPVT collector: Simulation of energy and environmental performance

被引:44
作者
Calise, F. [1 ]
d'Accadia, M. Dentice [1 ]
Roselli, C. [2 ]
Sasso, M. [2 ]
Tariello, F. [2 ]
机构
[1] Univ Naples Federico II, DII, I-80125 Naples, Italy
[2] Univ Sannio, DING, I-82100 Benevento, Italy
关键词
Desiccant-based AHU; CPVT collector; Simulation; Solar cooling; Energy and environmental analysis; COOLING SYSTEM; SOLAR; DRIVEN; DEHUMIDIFICATION; DESIGN; CYCLE;
D O I
10.1016/j.solener.2013.11.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Desiccant-based Air Handling Units (AHU) provide significant technical and energy/environmental advantages with respect to conventional systems, especially when the regeneration of the desiccant material is obtained by means of a renewable energy source, such as solar energy. Such thermal energy may be provided by CPVT (Concentrating Photovoltaic/Thermal) collectors, simultaneously producing also electricity, which are considered one of the most promising solar technologies. In fact, CPVT thermal energy can drive (integrated by a natural-gas fired boiler) a desiccant-based AHU, since the silica-gel wheel, used for the dehumidification and included in that system, must be continuously regenerated. Here, the regeneration temperature of the wheel (40-70 degrees C, depending on the dehumidification required) is compatible with the CPVT outlet temperature (80-100 degrees C). Simultaneously, the electricity produced by CPVT collectors can feed the auxiliary devices of the plant. Furthermore, the heat supplied from the solar collector can be used for the pre and post heating of the process air during winter operation. A test facility in which a silica-gel desiccant wheel is included in a hybrid AHU has been located in Benevento (Southern Italy). In this paper, a desiccant-based AHU has been coupled with a novel CPVT, consisting of a parabolic trough concentrator and a linear triangular receiver. In order to analyze the system, a TRNSYS project based on models available in literature (some of them were calibrated and validated with experimental tests) has also been developed. Electricity produced by the CPVT collector is used to power the auxiliaries of the AHU, the chiller and also to balance the electric load of users, while thermal energy is used to heat the regeneration air flow during the summer period and the process air in the winter. Electricity in excess is sold to the grid, whereas the thermal energy in excess is used for production of domestic hot water (DHW). Eventual integrations of electricity and thermal energy are provided by the electric grid and by a gas-fired bolier, respectively. Energy and environmental performance of the overall system in terms of Primary Energy Saving and emission reduction with respect to a reference case are evaluated. The heat provided by the CPVT covers about 60% of thermal energy required by regeneration air and 30% of process air in winter operating mode. On an annual basis, the analyzed system obtains a Primary Energy Saving between 81% and 89%, depending on the DHW required. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:574 / 594
页数:21
相关论文
共 74 条
  • [51] Case study of a two-stage rotary desiccant cooling/heating system driven by evacuated glass tube solar air collectors
    Li, H.
    Dai, Y. J.
    Li, Y.
    La, D.
    Wang, R. Z.
    [J]. ENERGY AND BUILDINGS, 2012, 47 : 107 - 112
  • [52] Performance investigation and optimization of the Trough Concentrating Photovoltaic/Thermal system
    Li, M.
    Ji, X.
    Li, G. L.
    Yang, Z. M.
    Wei, S. X.
    Wang, L. L.
    [J]. SOLAR ENERGY, 2011, 85 (05) : 1028 - 1034
  • [53] The performance analysis of the Trough Concentrating Solar Photovoltaic/Thermal system
    Li, M.
    Li, G. L.
    Ji, X.
    Yin, F.
    Xu, L.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (06) : 2378 - 2383
  • [54] Performance study of solar cell arrays based on a Trough Concentrating Photovoltaic/Thermal system
    Li, Ming
    Ji, Xu
    Li, Guoliang
    Wei, Shengxian
    Li, YingFeng
    Shi, Feng
    [J]. APPLIED ENERGY, 2011, 88 (09) : 3218 - 3227
  • [55] COUPLED HEAT AND MASS-TRANSFER IN REGENERATORS - PREDICTION USING AN ANALOGY WITH HEAT-TRANSFER
    MACLAINECROSS, IL
    BANKS, PJ
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1972, 15 (06) : 1225 - +
  • [56] Cooling potential of ventilated PV facade and solar air heaters combined with a desiccant cooling machine
    Mei, L
    Infield, D
    Eicker, U
    Loveday, D
    Fux, V
    [J]. RENEWABLE ENERGY, 2006, 31 (08) : 1265 - 1278
  • [57] Solar cooling with concentrating photovoltaic/thermal (CPVT) systems
    Mittelman, Gur
    Kribus, Abraham
    Dayan, Abraham
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (09) : 2481 - 2490
  • [58] The experimental investigation on the performance of a low temperature waste heat-driven multi-bed desiccant dehumidifier (MBDD) and minimization of entropy generation
    Myat, Aung
    Thu, Kyaw
    Choon, Ng Kim
    [J]. APPLIED THERMAL ENGINEERING, 2012, 39 : 70 - 77
  • [59] Annual output estimation of concentrator photovoltaic systems using high-efficiency InGaP/InGaAs/Ge triple-junction solar cells based on experimental solar cell's characteristics and field-test meteorological data
    Nishioka, K
    Takamoto, T
    Agui, T
    Kaneiwa, M
    Uraoka, Y
    Fuyuki, T
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2006, 90 (01) : 57 - 67
  • [60] Solar cooling and heating plants: An energy and economic analysis of liquid sensible vs phase change material (PCM) heat storage
    Noro, M.
    Lazzarin, R. M.
    Busato, F.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 39 : 104 - 116