Assessment of compliance of phasor measurement units (PMUs) for smart grid applications

被引:4
|
作者
Kaliappan, P. [1 ]
Meera, K. S. [1 ]
Selvan, M. P. [2 ]
机构
[1] Cent Power Res Inst, Bangalore 560080, Karnataka, India
[2] Natl Inst Technol Tiruchirappalli, Trichy 620015, India
关键词
frames per second (FPS); frequency error (FE); global positioning system (GPS); phasor measurement unit (PMU); rate of change of frequency error (RFE); synchrophasor; total vector error (TVE);
D O I
10.1002/2050-7038.12835
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a method for evaluating phasor measurement units (PMUs) using the Fluke PMU Calibration system (6135A/PMUCAL), in both steady state and transient conditions, considering its applications in a smart power transmission system. Two numerical distance protection intelligent electronic devices (IEDs) enabled with PMU functionalities and one standalone PMU, are evaluated at different reporting rates (10, 25 and 50FPS) for both M and P class, at nominal frequency of 50 Hz. The PMUs are tested for critical parameters such as total vector error (TVE), response time, frequency error (FE), delay time, and rate of change of frequency error (RFE). The entire testing process is fully automated and controlled remotely. A detailed review of the PMU tests data output is conducted and a comprehensive analysis of the results are presented. The PMU performance is evaluated for compliance with IEEE C37.118-1:2011 and IEEE C37.118-1a:2014 product and standards certification. This automated testing methodology makes the entire testing process simple, accurate, and very efficient.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Optimal Placement of Phasor Measurement Units for Smart Grid Applications
    Vijayalakshmi, S.
    Kavitha, D.
    2018 NATIONAL POWER ENGINEERING CONFERENCE (NPEC), 2018,
  • [2] A Brief Review of Phasor Measurement Units as Sensors for Smart Grid
    Mohanta, Dusmanta Kumar
    Murthy, Cherukuri
    Roy, Diptendu Sinha
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (04) : 411 - 425
  • [3] Communication Feasibility Analysis for Smart Grid With Phasor Measurement Units
    Ghosh, Debomita
    Ghose, T.
    Mohanta, D. K.
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2013, 9 (03) : 1486 - 1496
  • [4] Optimal Placement of Phasor Measurement Units for State Estimation in Smart Grid
    Var, Hakan
    Turkay, Belgin Emre
    2016 NATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND BIOMEDICAL ENGINEERING (ELECO), 2016, : 6 - 10
  • [5] Robust and Economical Placement of Phasor Measurement Units in Indian Smart Grid
    Rihan, Mohd
    Ahmad, Mukhtar
    Beg, M. Salim
    Anees, M. Anas
    2013 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2013,
  • [6] Noncircular Attacks on Phasor Measurement Units for State Estimation in Smart Grid
    Mohammadi, Arash
    Plataniotis, Konstantinos N.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2018, 12 (04) : 777 - 789
  • [7] A Fast Harmonic Phasor Measurement Method for Smart Grid Applications
    Jain, Sachin K.
    Jain, Preeti
    Singh, Niwas
    IEEE TRANSACTIONS ON SMART GRID, 2017, 8 (01) : 493 - 502
  • [8] Virtualization of Synchronized Phasor Measurement Units Within Real-Time Simulators for Smart Grid Applications
    Al-Hammouri, A. T.
    Nordstrom, L.
    Chenine, M.
    Vanfretti, L.
    Honeth, N.
    Leelaruji, R.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [9] Application of phasor measurement units (PMUs) in the model of 22 kV network
    Hropko, Daniel
    Ivanecky, Jan
    Altus, Juraj
    PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 64 - 67
  • [10] Optimal Meter Placement by Reconciliation Conventional Measurements and Phasor Measurement Units (PMUs)
    Kaihani, Reza
    Seifi, Ali Reza