Axial Micromotion Locking Plate Construct Can Promote Faster and Stronger Bone Healing in an Ovine Osteotomy Model

被引:16
作者
Han, Zhihua [1 ,2 ]
Wu, Jianhong [1 ]
Deng, Guoying [1 ]
Bi, Chun [1 ]
Wang, Jiandong [1 ]
Wang, Qiugen [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Orthopaed & Traumatol, Ctr Trauma, Shanghai, Peoples R China
[2] Sino Euro Orthopaed Network, Homburg, Germany
关键词
bone healing; animal model; bone implant; locking plate fixation; interfragmentary motion; FAR CORTICAL LOCKING; IN-VITRO; FIXATION; DYNAMIZATION; STABILIZATION; STIFFNESS; FEMUR;
D O I
10.3389/fbioe.2020.593448
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Fixing bone fractures with controlled axial interfragmentary micromotion improves bone healing; however, the optimal type of implant construct for this purpose is still lacking. The present study describes a novel axial micromotion locking plate (AMLP) construct that allows axial interfragmentary micromotion of 0.3 or 0.6 mm. We investigated whether the AMLP constructs enhance bone healing compared to an ordinary locking plate (LP) using an ovine osteotomy model. The stiffness of the constructs was tested under axial loading. We created a 3-mm osteotomy in the left hind leg tibia of sheep that was then stabilized with a 0.3- or 0.6-mm AMLP or LP construct (n = 6/group). Bone healing was monitored weekly by X-ray radiography starting from week 3 after surgery. At week 9, the specimens were collected and evaluated by computed tomography and torsional testing. We found that the AMLPs had a lower stiffness than the LP; in particular, the stiffness of the 0.6-mm AMLP construct was 86 and 41% lower than that of the LP construct for axial loads 200 N, respectively. In the in vivo experiments, tibial osteotomies treated with the 0.6-mm AMLP construct showed the earliest maximum callus formation (week 5) and the highest volume of bone callus (9.395 +/- 1.561 cm(3) at week 9). Specimens from this group also withstood a 27% greater torque until failure than those from the LP group (P = 0.0386), with 53% more energy required to induce failure (P = 0.0474). These results demonstrate that AMLP constructs promote faster and stronger bone healing than an overly rigid LP construct. Moreover, better bone healing was achieved with an axial micromotion of 0.6 mm as compared to 0.3 mm.
引用
收藏
页数:9
相关论文
共 24 条
[1]   Biomechanical Considerations for Surgical Stabilization of Osteoporotic Fractures [J].
Bogunovic, Ljiljana ;
Cherney, Steven M. ;
Rothermich, Marcus A. ;
Gardner, Michael J. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2013, 44 (02) :183-+
[2]   Dynamic Stabilization with Active Locking Plates Delivers Faster, Stronger, and More Symmetric Fracture-Healing [J].
Bottlang, Michael ;
Tsai, Stanley ;
Bliven, Emily K. ;
von Rechenberg, Brigitte ;
Klein, Karina ;
Augat, Peter ;
Henschel, Julia ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (06) :466-474
[3]   Far Cortical Locking Can Improve Healing of Fractures Stabilized with Locking Plates [J].
Bottlang, Michael ;
Lesser, Maren ;
Koerber, Julia ;
Doornink, Josef ;
von Rechenberg, Brigitte ;
Augat, Peter ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. ;
Marsh, J. Lawrence .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07) :1652-1660
[4]  
Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
[5]   Far Cortical Locking Enables Flexible Fixation With Periarticular Locking Plates [J].
Doornink, Josef ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. ;
Bottlang, Michael .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 :S29-S34
[6]   Motion Predicts Clinical Callus Formation Construct-Specific Finite Element Analysis of Supracondylar Femoral Fractures [J].
Elkins, Jacob ;
Marsh, J. Lawrence ;
Lujan, Trevor ;
Peindl, Richard ;
Kellam, James ;
Anderson, Donald D. ;
Lack, William .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (04) :276-284
[7]   Screw position affects dynamic compression plate strain in an in vitro fracture model [J].
Ellis, T ;
Bourgeault, CA ;
Kyle, RF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (05) :333-337
[8]   Influence of the number of cortices on the stiffness of plate fixation of diaphyseal fractures [J].
ElMaraghy, AW ;
ElMaraghy, MW ;
Nousiainen, M ;
Richards, RR ;
Schemitsch, EH .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) :186-191
[9]  
Foux A, 1997, CLIN ORTHOP RELAT R, P232
[10]   Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots [J].
Gardner, Michael J. ;
Nork, Sean E. ;
Huber, Phillipe ;
Krieg, James C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (06) :652-656