Observer Variation in the Echocardiographic Measurement of Maximum Atrial Septal Excursion: A Comparison of M-Mode with Two-Dimensional or Transesophageal Echocardiography

被引:4
|
作者
Garg, Rajeev
Khaja, Azam
Madsen, Richard [2 ]
Alpert, Martin A.
Tejwani, Lokesh
Aggarwal, Kul [1 ,3 ]
机构
[1] Univ Missouri, Hlth Sci Ctr, Div Cardiol, Sch Med, Columbia, MO 65211 USA
[2] Univ Missouri, Sch Med, Off Med Res, Columbia, MO USA
[3] Harry S Truman Mem Vet Hosp, Cardiol Sect, Columbia, MO USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2009年 / 26卷 / 10期
关键词
maximum atrial septal excursion; M-mode echocardiography; two-dimensional echocardiography; transesophageal echocardiography; observer variation; atrial septal aneurysm; PATENT FORAMEN OVALE; CRYPTOGENIC STROKE; RISK-FACTORS; ANEURYSM; CLASSIFICATION; EVENTS; ADULTS;
D O I
10.1111/j.1540-8175.2009.00964.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrial septal aneurysm is typically diagnosed by transthoracic two-dimensional or transesophageal echocardiography (2DE or TEE). Such techniques are highly dependent on visual inspection which predisposes to observer variation. This study compares inter-and intraobserver variations in the measurement of maximum atrial septal excursion (MASE) obtained using transthoracic M-mode echocardiography (MME) with that obtained using 2DE or TEE. Methods: Consecutive patients with highly mobile atrial septal motion by visual inspection during 2DE or TEE were studied. MASE was estimated visually on 2DE or TEE. MME tracings were obtained with the cursor bisecting the parabola formed by the atrial septum at its maximum deviation from the midline. Electronic calipers were used to measure MASE for all echocardiographic techniques. Two observers provided two measurements each. Observer variation was determined by assessing standard deviation and confidence intervals of inter-and intraobserver differences. Results: Interobserver analysis showed standard deviations of 0.077 cm (95% CI 0.065-0.094) for MME and 0.280 cm (95% CI 0.242-0.334) for 2DE or TEE. Intraobserver analysis showed standard deviations of 0.08 cm (95% CI 0.068-0.101) for MME and 0.318 cm (95% CI 0.274-0.381) for 2DE or TEE. The mean magnitude of measured MASE was 0.44 cm higher with MME than with 2DE or TEE (95% CI 0.068-0.101). Conclusions: MME assessment of MASE is associated with substantially lower inter-and intraobserver variation than 2DE or TEE assessment. The magnitude of MASE is substantially higher with MME than with 2DE or TEE. (ECHOCARDIOGRAPHY, Volume 26, November 2009)
引用
收藏
页码:1122 / 1126
页数:5
相关论文
共 33 条
  • [21] Usefulness of the Right Parasternal Approach to Evaluate the Morphology of Atrial Septal Defect for Transcatheter Closure Using Two-Dimensional and Three-Dimensional Transthoracic Echocardiography
    Watanabe, Nobuhisa
    Taniguchi, Manabu
    Akagi, Teiji
    Tanabe, Yasuharu
    Toh, Norihisa
    Kusano, Kengo
    Ito, Hiroshi
    Koide, Norio
    Sano, Shunji
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (04) : 376 - 382
  • [22] Comparison of the effective orifice area of prosthetic mitral valves using two-dimensional versus three-dimensional transesophageal echocardiography
    Zhou, Lei
    Wei, Hai-yan
    Ge, Ya-li
    Ding, Zheng-nian
    Shi, Hong-wei
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (03)
  • [23] Impact of atrial septal defect device size on biventricular global and regional function: a two-dimensional strain echocardiographic study
    Alkhateeb, Areej
    Roushdy, Alaa
    Hasan-Ali, Hosam
    Kishk, Yehia T.
    El Sayegh, Aya
    Hassan, Ayman K. M.
    CARDIOLOGY IN THE YOUNG, 2022, 32 (05) : 746 - 754
  • [24] Is It Time to Move on from Two-Dimensional Transesophageal to Three-Dimensional Transthoracic Echocardiography for Assessment of Left Atrial Appendage? Review of Existing Literature
    Kumar, Vineet
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (01): : 112 - 116
  • [25] Comparison of Two-Dimensional Versus Real-Time Three-Dimensional Transesophageal Echocardiography for Evaluation of Patent Foramen Ovale Morphology
    Tanaka, Jun
    Izumo, Masaki
    Fukuoka, Yoko
    Saitoh, Takeji
    Harada, Kenji
    Harada, Kazumasa
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (07) : 1052 - 1056
  • [26] A new method for measurement of left atrial volumes using 64-slice spiral computed tomography: Comparison with two-dimensional echocardiographic techniques
    Christiaens, Luc
    Lequeux, Benoit
    Ardilouze, Paul
    Ragot, Stephanie
    Mergy, Jean
    Herpin, Daniel
    Bonnet, Benjamin
    Allal, Joseph
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 131 (02) : 217 - 224
  • [27] Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale
    Monte, Ines
    Grasso, Stefania
    Licciardi, Salvatore
    Badano, Luigi P.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (03): : 245 - 249
  • [28] Measuring Linear Left Ventricular Mass-Do M-Mode and Two-Dimensional Linear Measurements Produce the Same Results in Healthy Volunteers?
    Whalley, Gillian A.
    Gamble, Greg D.
    Harrington, Allanah
    Dugo, Clementina
    Morgan, Angela
    Ikenasio, Bettina
    Deo, Arun
    Crengle, Sue
    Christiansen, Jonathan
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2024, 37 (08) : 806 - 807
  • [29] Quantification of Right Atrial-Indexed End-Systolic Volumes and Emptying Fraction in Children Undergoing Cardiac Surgery With Two-Dimensional Transesophageal Echocardiography: A Prospective Observational Study
    Kiran, Molli
    Misra, Satyajeet
    Pr, Suneel
    Babu, Saravana
    Anand, Asha
    Koshy, Thomas
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (01) : 202 - 207
  • [30] Left ventricular longitudinal strain is a major determinant of CT-derived three-dimensional maximum principal strain: comparison with two-dimensional speckle tracking echocardiography
    Kinoshita, Masaki
    Tanabe, Yuki
    Yoshida, Kazuki
    Kurata, Akira
    Kobayashi, Yusuke
    Uetani, Teruyoshi
    Inoue, Katsuji
    Nishimura, Kazuhisa
    Ikeda, Shuntaro
    Mochizuki, Teruhito
    Kido, Teruhito
    Yamaguchi, Osamu
    HEART AND VESSELS, 2022, 37 (01) : 31 - 39