High placement of noncemented acetabular components in revision total hip arthroplasty - A concise follow-up, at a minimum of fifteen years, of a previous report

被引:44
作者
Hendricks, Kelly J.
Harris, William H.
机构
[1] Massachusetts Gen Hosp, Harris Orthopaed Biomech & Biomat Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Orthopaed Surg, Boston, MA 02114 USA
[3] Harvard Med Sch, Boston, MA USA
关键词
D O I
10.2106/JBJS.E.00247
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We previously reported the average ten-year results associated with the use of porous-coated noncemented acetabular shells that were placed at a high hip center at the time of revision total hip arthroplasty in thirty-four patients (thirty-six hips) with severe acetabular bone loss. We now report the average 16.8-year results for twenty-one patients (twenty-three hips). Of the original cohort of forty-four patients (forty-six hips), thirty-nine patients (forty-one hips; 89%) retained the shell. Two shells (4.3%) were revised because of aseptic loosening, and three (6.5%) were revised because of infection. Six femoral components were revised because of femoral osteolysis, and seven were revised because of aseptic loosening without osteolysis. On the basis of our results after an average duration of follow-up of 16.8 years, we believe that the placement of an uncemented acetabular component at a high hip center continues to be an excellent technique for revision total hip arthroplasty in selected patients with severe acetabular bone loss. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:2231 / 2236
页数:6
相关论文
共 14 条
[1]   TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[2]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[3]   Acetabular revision arthroplasty using so-called jumbo cementless components - An average 7-year follow-up study [J].
Dearborn, JT ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :8-15
[4]   High placement of an acetabular component inserted without cement in a revision total hip arthroplasty - Results after a mean of ten years [J].
Dearborn, JT ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (04) :469-480
[5]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]   Revision of failed acetabular components with use of so-called jumbo noncemented components - A concise follow-up of a previous report [J].
Hendricks, KJ ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (03) :559-563
[8]  
Kelley S S, 1994, J Arthroplasty, V9, P503
[9]   Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years [J].
Lachiewicz, PF ;
Poon, ED .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07) :980-984
[10]  
LEOPOLD SS, 1999, CLIN ORTHOP RELAT R, V369, P179