Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study

被引:11
作者
Di Fiore, Adolfo [1 ]
Graiff, Lorenzo [1 ]
Savio, Gianpaolo [2 ]
Granata, Stefano [1 ]
Basilicata, Michele [3 ]
Bollero, Patrizio [3 ]
Meneghello, Roberto [4 ]
机构
[1] Univ Padua, Dept Neurosci, Sect Prosthet & Digital Dent, I-35100 Padua, Italy
[2] Univ Padua, Dept Civil Environm & Architectural Engn, I-35100 Padua, Italy
[3] Univ Roma Tor Vergata, Dept Syst Med, I-00133 Rome, Italy
[4] Univ Padua, Dept Management & Engn, I-35100 Padua, Italy
关键词
CAD; CAM; digital impression; intra-oral scanner; accuracy; full arch; dental implant;
D O I
10.3390/ijerph19084719
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: We compare the accuracy of new intraoral scanners (IOSs) in full-arch digital implant impressions. Methods: A master model with six scan bodies was milled in poly(methyl methacrylate), measured by using a coordinate measuring machine, and scanned 15 times with four IOSs: PrimeScan, Medit i500, Vatech EZ scan, and iTero. The software was developed to identify the position points on each scan body. The 3D position and distance analysis were performed. Results: The average and +/- standard deviation of the 3D position analysis was 29 mu m +/- 6 mu m for PrimeScan, 39 mu m +/- 6 mu m for iTero, 48 mu m +/- 18 mu m for Mediti500, and 118 mu m +/- 24 mu m for Vatech EZ scan (p < 0.05). Conclusions: All IOSs are able to make a digital complete implant impression in vitro according to the average misfit value reported in literature (150 mu m); however, the 3D distance analysis showed that only the Primescan and iTero presented negligible systematic error sources.
引用
收藏
页数:6
相关论文
共 23 条
[1]   Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review [J].
Ahlholm, Pekka ;
Sipila, Kirsi ;
Vallittu, Pekka ;
Jakonen, Minna ;
Kotiranta, Ulla .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01) :35-41
[2]   Advancements in CAD/CAM technology: Options for practical implementation [J].
Alghazzawi, Tariq F. .
JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (02) :72-84
[3]  
[Anonymous], 2019, ISO 5725-2
[4]   In vitro comparison of trueness of 10 intraoral scanners for implant-supported complete-arch fixed dental prostheses [J].
Bilmenoglu, Caglar ;
Cilingir, Altug ;
Geckili, Onur ;
Bilhan, Hakan ;
Bilgin, Tayfun .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06) :755-760
[5]  
Branemark PI., 1985, TISSUE INTEGRATED PR, P253
[6]   The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans [J].
Cakmak, Gulce ;
Yilmaz, Hakan ;
Trevino, Alejandro ;
Kokat, Ali Murat ;
Yilmaz, Burak .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) :533-541
[7]  
Ceruso F M, 2017, Oral Implantol (Rome), V10, P349, DOI 10.11138/orl/2017.10.4.349
[8]   Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners [J].
Di Fiore, Adolfo ;
Meneghello, Roberto ;
Graiff, Lorenzo ;
Savio, Gianpaolo ;
Vigolo, Paolo ;
Monaco, Carlo ;
Stellini, Edoardo .
JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) :396-403
[9]   Digital vs Conventional Workflow for Screw-Retained Single-Implant Crowns: A Comparison of Key Considerations [J].
Di Fiore, Adolfo ;
Vigolo, Paolo ;
Graiff, Lorenzo ;
Stellini, Edoardo .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (06) :577-579
[10]   In Vitro Implant Impression Accuracy Using a New Photopolymerizing SDR Splinting Material [J].
Di Fiore, Adolfo ;
Meneghello, Roberto ;
Savio, Gianpaolo ;
Sivolella, Stefano ;
Katsoulis, Joannis ;
Stellini, Edoardo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 :E721-E729