A new mixing-oxygenating technology for water quality improvement of urban water source and its implication in a reservoir

被引:33
作者
Cong, Hai-Bing [1 ]
Huang, Ting-Lin [1 ]
Chai, Bei-Bei [1 ]
Zhao, Jian-Wei [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi Prov, Peoples R China
基金
中国国家自然科学基金;
关键词
Water-lifting Aerator; Reservoir; Sediment; Mix; Aeration; Ammonia-nitrogen; LAKE;
D O I
10.1016/j.renene.2009.02.007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Water-lifting Aerator, which is a retrofit of the hydraulic gun, was developed to oxygenate lower-layer water and mix the water on the upper and lower layers in stratified reservoirs where pollutants increase from sediments because of anoxic condition in the lower-layer water. The Fenhe reservoir began to supply raw water to the drinking water treatment plant of the City of Taiyuan, China in 2004. The surface of the reservoir froze in winter, and the lower-layer water above the reservoir bed became anoxic because of oxygen consumption by the sediments. Hence, ammonia-nitrogen released from the sediments and trapped in the lower-layer water. After the ice surface thawed in spring, the ammonia-nitrogen in the deepwater was brought up owing to the wind-wave mixing processes. Thus the concentration of ammonia-nitrogen in the outlet water exceeded the permitted level, and the water supply from the Fenhe reservoir had to be cut off. To solve the problem, the Water-lifting Aerator system was installed in the reservoir in the winter of 2005, the dissolved oxygen concentration in the lower-layer water has been maintained at more than 3 mg/L and the ammonia-nitrogen concentration has been reduced to less than 0.1 mg/L. The ammonia-nitrogen concentration in the outlet water is a 95% reduction compared to the same period of last year before the system installation. Since then the water supply from the Fenhe reservoir has no longer been interrupted. Compared with traditional water treatment technology to remove ammonia-nitrogen, the new technology saves energy for 77%. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2054 / 2060
页数:7
相关论文
共 11 条
[1]   Predicting oxygen transfer and water flow rate in airlift aerators [J].
Burris, VL ;
McGinnis, DF ;
Little, JC .
WATER RESEARCH, 2002, 36 (18) :4605-4615
[2]   Bubble dynamics and oxygen transfer in a hypolimnetic aerator [J].
Burris, VL ;
Little, JC .
WATER SCIENCE AND TECHNOLOGY, 1998, 37 (02) :293-300
[3]  
He WJ., 2006, NOVEL TECHNOLOGY DRI, DOI DOI 10.3390/ijerph13040427
[4]   Understanding and management of cyanobacterial blooms in sub-tropical reservoirs of Queensland, Australia [J].
Jones, GJ ;
Poplawski, W .
WATER SCIENCE AND TECHNOLOGY, 1998, 37 (02) :161-168
[5]   Hypolimnetic aeration in Lake Tegel, Berlin [J].
Lindenschmidt, KE ;
Hamblin, PF .
WATER RESEARCH, 1997, 31 (07) :1619-1628
[6]   HYPOLIMNETIC AERATORS - PREDICTING OXYGEN-TRANSFER AND HYDRODYNAMICS [J].
LITTLE, JC .
WATER RESEARCH, 1995, 29 (11) :2475-2482
[7]   Phosphorus characteristics of settling and suspended particles in Lake Erken [J].
Pettersson, K .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 266 (1-3) :79-86
[8]  
Seo D, 1995, P 6 INT C CONS MAN L, V1, P336
[9]  
Simmons J, 1998, WATER SCI TECHNOL, V37, P309, DOI 10.1016/S0273-1223(98)00038-9
[10]  
Visser PM, 1995, WATER SCI TECHNOL, V32, P53, DOI 10.1016/0273-1223(95)00679-6